Laserfiche WebLink
PROJECT NAME: HULTS RESIDENCE ADDITION <br /> JOB: X10-2854 <br /> **Current Level = 1 <br /> DIAPH GRID WIND SEISMIC GRID WIND SEISMIC <br /> A B I A 2118 623 I B 2118 623 <br /> ** Direction = 2 ** <br /> **Current Level = 2 <br /> DIAPH GRID WIND SEISMIC GRID WIND SEISMIC <br /> 1 2 1 1 1489 831 1 2 1489 831 <br /> **Current Level = 1 <br /> DIAPH GRID WIND SEISMIC GRID WIND SEISMIC <br /> 1 2 I 1 1337 544 12 1337 544 <br /> ** GRID LINE REACTIONS ** <br /> NUM LEVEL GRID LENGTH WIND SEISMIC <br /> (ft) (lb) (lb) <br /> 0 2 A 13.92 1754 908 <br /> 1 2 B 13.92 1754 908 <br /> 2 1 A 13.92 2118 623 <br /> 3 1 B 13.92 2118 623 <br /> 4 2 1 20.12 1489 831 <br /> 5 2 2 20.12 1489 831 <br /> 6 1 1 20.12 1337 544 <br /> 7 1 2 20.12 1337 544 <br /> Redundancy calculation rho, per ASCE 12.3.4.2 - Summary <br /> CUSTOM DESIGN & ENGINEERING, INC. <br /> March 3, 2022 Page 12/ 67 <br /> Copyright©2022 Custom Design&Engineering,Inc.All rights reserved. <br />