Laserfiche WebLink
PROJECT NAME: HULTS RESIDENCE ADDITION <br /> JOB: X10-2854 <br /> Level = 2 <br /> Condition <br /> Direction A B Rho <br /> 1 PASS FAIL 1.0 <br /> 2 FAIL FAIL 1.3 <br /> Level = 1 <br /> Condition <br /> Direction A B Rho <br /> 1 FAIL FAIL 1.3 <br /> 2 PASS FAIL 1.0 <br /> Design rho for Direction 1 = 1.3 <br /> Design rho for Direction 2 = 1.0 <br /> Analysis <br /> Redundancy calculations <br /> *** D E S I G N L EVE L = 2 *** <br /> *** Direction 1 *** <br /> Check condition A <br /> Grid Line A, Height = 8.75 ft <br /> Length Height/Length <br /> 1 4.29' 2.04 <br /> 2 4.00' 2.19 <br /> Grid Line B, Height = 8.75 ft <br /> Length Height/Length <br /> 1 4.29' 2.04 <br /> 2 4.00' 2.19 <br /> Total shear wall length = 16.6 ft <br /> Check shear wall piers that have h/L > 1.0. Remove that pier and check the length of removed pier ratio to <br /> CUSTOM DESIGN & ENGINEERING, INC. <br /> March 3, 2022 Page 13 /67 <br /> Copyright CD 2022 Custom Design&Engineering,Inc.All rights reserved. <br />