My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10115 EVERGREEN WAY PEP BOYS 2025-04-14
>
Address Records
>
EVERGREEN WAY
>
10115
>
PEP BOYS
>
10115 EVERGREEN WAY PEP BOYS 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 3:36:06 PM
Creation date
3/11/2025 10:32:57 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10115
Tenant Name
PEP BOYS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Intrusion Alarm Systems - B8512G IP control panel, 8 areas, 99 points <br />4111 <br />Event log <br />The event log stores up to 2048 local and reported <br />events. The event log includes time, date, event, area, <br />point, and user. View the event log from a keypad or <br />use RPS to remotely retrieve event information. When <br />the event log reaches a programmed threshold of <br />stored events, it can send an optional report to a <br />receiver. <br />Scheduled events (SKEDs) <br />The internal clock and calendar start individually <br />scheduled events (SKEDs). SKEDs perform several <br />functions such as turn on or off, relay control, or point <br />bypassing. <br />The control panel offers: <br />• 40 scheduled events with up to 31 different <br />functions <br />• 8 opening windows and 8 closing windows <br />• 8 user group windows <br />• Day -of -week, date -of -month, or holiday only <br />schedules <br />• 4 holiday schedules of 366 days (leap year) <br />Dual bus and SDI keypad retrofits <br />The dual SD12 device bus design provides greater <br />installation flexibility, such as bus isolation for <br />Intrusion and Fire. To use popular SDI keypads (for <br />example D1255 and D1260), program one of the two <br />SD12 buses for SDI operation. <br />ZONEX and POPEX retrofits <br />To retrofit legacy Bosch control panels that use <br />ZONEX and POPEX devices, the control panel is <br />compatible with the B600 Retrofit (ZONEX) Module. <br />The B600 adds two ZONEX buses to the control panel <br />which can connect to existing legacy point bus <br />(POPEX) devices (for example, the D8125). <br />Programming <br />Installers can perform limited programming on -site <br />with a keypad (critical parameters; such as account <br />IDs, central station and RPS IP addresses and phone <br />numbers, reporting formats, and more). They can also <br />do full programming on -site or remotely (attended or <br />unattended) with RPS. A programmable system <br />passcode prevents unauthorized remote <br />programming. <br />The following table shows the available languages for <br />RPS <br />English <br />Dutch <br />French <br />German <br />Hungarian <br />RPS programming RPS custom text* <br />RPS programming RPS custom text* <br />Italian ✓ <br />Portuguese ✓ <br />Spanish ✓ <br />Swedish ✓ <br />* RPS custom text is text, that can be entered in RPS <br />and which will then be displayed on keypads and on <br />the mobile app. <br />Diagnostics <br />Keypads and RPS offer diagnostic help for monitoring <br />and troubleshooting. The diagnostics features allow <br />you to view the status of the wired and wireless <br />devices. The features provide the status of the control <br />panel and its connected devices, such as firmware <br />version, power, and missing conditions. View the <br />status of each area. <br />3rd Party Integrations <br />The control panel provides options for integration <br />with software applications and solutions. Depending <br />on the application, options include a Bosch SDK, RPS- <br />API, Bosch proprietary MODE 2 or OPC interface. The <br />OPC interface enables key DA (Data Access) and AE <br />(Alarms & Events) to integrate with the Bosch BIS <br />solution or 3rd party OPC Classic systems. <br />Bosch Video Management System integration <br />With Bosch Video Management System (Bosch VMS) <br />and an intrusion system, the VMS operator has a <br />single user interface to monitor and control the <br />intrusion system combined with video surveillance. <br />With Bosch VMS and a control panel, the operator <br />can, for example: <br />• View videos triggered by intrusion events, including <br />all relevant information such as areas, point, and <br />user show in the display with the event. <br />• View areas, points, outputs, and doors - with their <br />statuses - on the Bosch VMS map, providing the <br />exact location in the system. <br />Turn on (arm) and turn off (disarm) areas. <br />• Bypass and unbypass points. <br />• Lock and unlock doors (Bosch VMS 6.0 and higher). <br />Requirements to integrate Bosch VMS with a control <br />panel: <br />• A licensed Bosch VMS system using Professional <br />Editions v5.5 or higher or Bosch VMS Enterprise <br />Edition v5.5 or higher. <br />✓ Expansion license to integrate the intrusion control <br />panel. One license needed per control panel. Order <br />✓ number MBX-XINT-xx for the expansion license <br />added to a Bosch VMS base license. Refer to the <br />✓ Bosch Video Management Software product page <br />on the Bosch website, www.boschsecurity.com. <br />✓ Access to the control panel account and Remote <br />Programming Software (RPS). <br />