Laserfiche WebLink
NAC output patterns <br />The NAC circuits can be set to produce the following <br />output patterns: <br />• Steady <br />• Temporal Code 3 <br />• Pulsed <br />• California March <br />• Wheelock Synch <br />• Gentex Synch <br />• System Sensor Synch <br />Status displays <br />There are eight local status display LEDs on the power <br />supply's printed circuit board that show the following <br />conditions: <br />• AC OK <br />• System Trouble <br />• Ground Fault <br />• Input Active <br />• Trouble Output 1, 2, 3, and 4 <br />DIP switch settings <br />If connected to the fire alarm control panel's option <br />bus, the power supply requires an option bus address. <br />Set this address through the DIP switches. <br />Set the DIP switches to choose: <br />• NAC or power supply output <br />• NAC Input Variable option <br />• AC Delay Time <br />Region egulatory compliance/quality marks <br />USA fuL <br />UL 864, Control Units and Accessories <br />for Fire Alarm Systems <br />UL <br />UL 1481, Power Supplies for Fire -Pro- <br />tective Signaling Systems <br />FM <br />FPP-RNAC-8A-4C <br />CSFM <br />see www.boschsecurity.com (the Bosch <br />website) <br />FDNY- <br />6101 <br />CoA <br />FDNY- <br />6173 <br />CoA <br />AWARNING <br />This product can expose you to chemicals including <br />lead, which is known to the State of California to <br />cause cancer and birth defects or other reproductive <br />harm. For more information go to: <br />www.P65Warnings.ca.gov. <br />Compatible Products <br />The FPP-RNAC-8A-4C is compatible with the D340 and <br />D341 Door holders. For additional FPP-RNAC-8A-4C <br />compatibility information, refer to the Smoke Detector <br />Compatibility List (FO1U010790) or the NAC <br />Compatibility List (F01U010791). <br />Wiring <br />All wiring is connected to the power supply board by <br />lift -gate terminals that can accept up to 12 AWG (ISO <br />4 mmz) wire. <br />Quantity Component <br />1 FPP-RNAC-8A-4C board <br />1 AE4 Large Enclosure (red), vented <br />1 Lock set with two #1358 (D102) keys (P/N: <br />F01U083084) <br />4 2.21 kO end -of -line (EOL) resistors (P/N: F01U034504) <br />For retrofitting applications, allowable EOL values are in <br />the range of 1 kf1 to 20 kf1 <br />1 Hardware pack <br />3 Cables (1 red and 1 black [14 AWG, 610 mm], 1 black <br />[14AWG,153 mm]) <br />1 Grounding wire (green,10 in.) with nut <br />3 Hex nuts with lock washers <br />7 standoffs and screws (mounting) <br />1 Literature <br />Installation manual <br />Electronic document downloads (EDD) <br />Release Notes <br />Technical specifications <br />Environmental Considerations <br />Temperature (operating) +32°F to +120°F (0°C to +49°C) <br />Inputs (NAC) <br />Response Time (input to output) 10 ms maximum <br />Outputs (auxiliary) <br />Auxiliary <br />Current (output) 750 mA maximum <br />Voltage (output) 24 VDC (regulated) <br />NAC <br />Output per circuit 2.5 A maximum <br />Output (total) 8 A (all NAC and auxiliary outputs) <br />Voltage (output) 24 VDC (regulated) <br />Voltage (standby) 5 VDC (regulated) <br />NAC (power supply) <br />Compatibility range 19.6 VDC to 27.5 VDC <br />Current (output) 1.3 A maximum <br />Inrush current 25 A at <40 ms <br />Voltage (output) 24 VDC nominal <br />