Laserfiche WebLink
�" MEMBER REPORT PASSED <br /> Floor, UB-04 <br /> 1 piece(s)5 1/2"x 21"24F-V4 DF Glulam <br /> Overall Length:23'9' <br /> i _:_ <br /> 11, I <br /> a o <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual(0 Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 12249 @ 23'3 1/4" 21450(6.00") Passed(57%) -- 1.0 D+0.75 L+0.75 S(All Spans) Member Type:Flush Beam <br /> Building Use:Residential <br /> Shear(Ibs) 8879 @ 21'4 3/4" 20405 Passed(44%) 1.00 1.0 D+ 1.0 L(All Spans) Building Code:IBC 2018 <br /> Pos Moment(Ft-Ibs) 58624©11'7 11/16" 75293 Passed(78%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.480 @ 11'10 7/16" 0.570 Passed(L/570) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> Total Load Defl.(in) 0.822 @ 11'10 7/16" 1.140 Passed(11333) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> • Deflection criteria:LL(L/480)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> •Critical positive moment adjusted by a volume factor of 0.93 that was calculated using length L=22'9 1/2". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Snow Total Accessories <br /> 1-Column-DF 7.25" 6.00" 3.34" 5009 5420 3943 14372 1 1/4"Rim Board <br /> 2-Column-DF 7.25" 6.00" 3.43" 5137 5679 3934 14750 1 1/4"Rim Board <br /> •Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 23'7"o/c <br /> Bottom Edge(Lu) 23'7"o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Dead Floor Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 1 1/4"to 23'7 3/4" N/A 28.1 -- -- <br /> 1-Uniform(PSF) 0 to 23'9"(Front) 10'6" 12.0 40.0 - Floor <br /> 2-Uniform(PLF) 0 to 23'9"(Front) N/A 90.0 - - Wall <br /> 3-Uniform(PSF) 0 to 23'9"(Front) 1'4" 12.0 25.0 Low Roof <br /> 4-Uniform(PSF) 0 to 23'9"(Front) 12' 12.0 - <br /> 25.0 Roof <br /> 5-Point(Ib) 9'2"(Front) N/A 278 562 -20 Linked from:UB-Ol, <br /> Support 1 <br /> 6-Point(Ib) 19'10"(Front) N/A 278 562 _20 Linked from:UB-Ol, <br /> Support 1 <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeusercom/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator lob Notes 5/5/2022 11:30:59 PM UTC <br /> Kelsi Bonner <br /> BTL Engineering ForteWEB v3.2,Engine:V8.2.0.17, Data: V8.1.0.16 <br /> (931)581-9272 <br /> kelsi.bonner@btleng.net Weyerhaeuser File Name: Peterson Garage-Everett <br /> U2.11 Page 5/8 <br />