My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3527 SHORE AVE 2025-04-17
>
Address Records
>
SHORE AVE
>
3527
>
3527 SHORE AVE 2025-04-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 3:53:27 PM
Creation date
3/13/2025 4:06:59 PM
Metadata
Fields
Template:
Address Document
Street Name
SHORE AVE
Street Number
3527
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEMBER REPORT PASSED <br /> Floor, UB-05 <br /> 1 piece(s)5 1/2"x 9"24F-V4 DF Glulam <br /> Overall Length:9'10 1/2' <br /> i i <br /> i <br /> i , <br /> t k <br /> 0 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual 0 Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(lbs) 4133 @ 9'9" 7013(3.00") Passed(59%) -- 1.0 D+ 1.0 L(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(Ibs) 2646©8'10 1/2" 8745 Passed(30%) 1.00 1.0 D+ 1.0 L(All Spans) Building Code:IBC 2018 <br /> Pos Moment(Ft-lbs) 6906 @ 4'11 5/8" 14850 Passed(47%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.134 @ 5'5/16" 0.235 Passed(L/843) -- 1.0 D+1.0 L(All Spans) <br /> Total Load Defl.(in) 0.187©5'1/4" 0.471 Passed(L/604) -- 1.0 D+1.0 L(All Spans) <br /> • Deflection criteria:LL(L/480)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> •Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L=9'5". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(lbs) <br /> Supports Total Available Required Dead Floor Live Snow Total Accessories <br /> 1-Column-DF 5.50" 5.50" 2.56" 3704 4562 2720 10986 Blocking <br /> 2-Stud wall-SPF 3.00" 3.00" 1.77" 1415 2718 384 4517 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 9'11"o/c <br /> Bottom Edge(Lu) 9'11"o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Dead Floor Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 9'10 1/2" N/A 12.0 -- -- <br /> 1-Uniform(PSF) 0 to 9'10 1/2"(Front) 10'6" 12.0 40.0 - Default Load <br /> 2-Point(Ib) 9'4 1/2"(Front) N/A 723 671 349 Linked from:UB-01, <br /> Support 2 <br /> Linked from:UB-03, <br /> 3-Point(Ib) 6"(Front) N/A 3033 2461 2755 Support 2 <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator Job Notes 5/5/2022 11:30:59 PM UTC <br /> Kelsi Bonner <br /> BTL Engineering ForteWEB v3.2,Engine:V8.2.0.17, Data:V8.1.O.16 <br /> (931)581-9272 <br /> kelsi.bonner@btleng.net Weyerhaeuser File Name: Peterson Garage-Everett <br /> U2.12 Page6/8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.