My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2520 MADISON ST DISH WIRELESS 2025-08-08
>
Address Records
>
MADISON ST
>
2520
>
DISH WIRELESS
>
2520 MADISON ST DISH WIRELESS 2025-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2025 2:10:48 PM
Creation date
3/14/2025 1:52:09 PM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
2520
Tenant Name
DISH WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mount Structural Analysis Report August 9, 2021 <br /> (3) 12.50-Ft T-Arm W/Tie Back puck connection Site ID: 102383-VZW/PORT GARDNER <br /> (Site Pro RMV12-496 SQNP) Page 13 <br /> Final Loading Configuration: <br /> The following equipment has been considered for the analysis of the mounts: <br /> Mount Equipment <br /> Elevation Elevation Quantity Manufacturer Model Status <br /> (ft) (ft) <br /> 6 Commscope NHH-45C-R2B Added <br /> 3 Ericsson AIR6449 Added <br /> 1 Antel BXA-70063-4CF-2-850MHZ (148286) Retained <br /> 117.00 117.00 1 Antel BXA-70063-8CF-2-850MHZ(148318) Retained <br /> 1 Antel BXA-70063-8CF-4-850M HZ(148320) Retained <br /> 3 Ericsson 8843 Added <br /> 3 Ericsson Unknown Added <br /> 1 Raycap OVP12 Added <br /> 3 Ericsson 4449 Retained <br /> 3 Ericsson RRUS32B2 Retained <br /> Any proposed antennas not currently installed should be mounted such that the centerline of the antennas does <br /> not exceed 6 inches vertically from the center of the antenna mount(s). <br /> Model Number Ports AKA <br /> RHSDC-1064-PF-48 2 OVP-2 <br /> RC3DC-3315-PF-48 6 OVP-6 <br /> RC3DC-3300-PF-48 6 OVP-6 <br /> RC3DC-4750-PF-48 6 OVP-6 <br /> RHSDC-6627-PF-48 12 OVP-12 <br /> RHSDC-6600-PF-48 12 OVP-12 <br /> Standard Conditions: <br /> 1. All engineering services are performed on the basis that the information provided to Tower Engineering <br /> Solutions and used in this analysis is current and correct. The existing equipment loading has been <br /> applied at locations determined from the supplied documentation and field observations. Any deviation <br /> from the loading locations specified in this report shall be communicated to Tower Engineering Solutions <br /> to verify deviation will not adversely impact the analysis. <br /> 2. Mounts are assumed to have been properly fabricated, installed and maintained in good condition, twist <br /> free and plumb in accordance with its original design and manufacturer's specifications. <br /> 3. For mount analyses completed from other data sources (including new replacement mounts) and not <br /> specifically mapped by TES, the mounts are assumed to have been properly fabricated, installed and <br /> maintained in good condition, twist free and plumb in accordance with its original design and <br /> manufacturer's specifications. <br /> 4. All member connections are assumed to have been designed to meet or exceed the load carrying <br /> capacity of the connected member unless otherwise specified in this report. <br /> 5. The mount was checked up to, and including, the bolts that fasten it to the mount collar/attachment and <br /> threaded rod connections in collar members if applicable. Local deformation and interaction between the <br /> mount collar/attachment and the supporting tower structure are outside the scope of this analysis. <br />