Laserfiche WebLink
Mount Structural Analysis Report August 9, 2021 <br /> (3) 12.50-Ft T-Arm W/Tie Back puck connection Site ID: 102383-VZW/PORT GARDNER <br /> (Site Pro RMV12-496 SQNP) Page 14 <br /> 6. All services are performed, results obtained, and recommendations made in accordance with generally <br /> accepted engineering principles and practices. Tower Engineering Solutions is not responsible for the <br /> conclusion, opinions, and recommendations made by others based on the information supplied. <br /> 7. Structural Steel Grades have been assumed as follows, if applicable, unless otherwise noted in this <br /> analysis: <br /> o Channel, Solid Round,Angle, Plate ASTM A36 (Gr. 36) <br /> o HSS (Rectangular) ASTM 500 (Gr. B-46) <br /> o Pipe ASTM A53 (Gr. B-35) <br /> o Threaded Rod F1554 (Gr. 36) <br /> o Bolts ASTM A325 <br /> Discrepancies between in-field conditions and the assumptions listed above may render this analysis <br /> invalid unless explicitly approved by Tower Engineering Solutions. <br /> Analysis Results: <br /> Component Utilization% Pass/Fail <br /> Standoff Arm 49.1% Pass <br /> Mount Pipes 33.1% Pass <br /> Face Horizontal 50.2% Pass <br /> Tie Back 6.2% Pass <br /> Structure Rating-(Controlling Utilization of all Components) 502% <br /> Recommendation: <br /> The proposed Site Prot RMV12-496 SQNP (T-Arm W/Tie Back puck connection) mounts are not <br /> Installed on the tower. The proposed mounts were assumed to be installed per the manufacturer's instructions, <br /> and it is assumed that they can be installed properly on the tower. TES cannot verify that the proposed mounts <br /> will fit properly and is not liable for any fit-up issues during installation. <br /> The proposed antenna mounts are SUFFICIENT for the final loading configuration and do not require <br /> modifications. <br /> ANSI/ASSP rigging plan review services compliant with the requirements of ANSI/TIA 322 are available for a <br /> Construction Class IV site or other, if required. Separate review fees will apply. <br /> Attachments: <br /> 1. Mount Photos <br /> 2. Analysis Calculations <br /> 3. Contractor Required Post Installation Inspection (PMI) Report Deliverables <br /> 4. Antenna Placement Diagrams <br />