Laserfiche WebLink
2 I B9512G Control Panels <br /> Functions opening doors.A standard system user must have a <br /> passcode,a credential (token or card),and <br /> Programmable outputs appropriate command authority permissions. <br /> • Four alarm-output patterns <br /> • Programmable bell test Door control <br /> Using the B901 Access Control Module or D9210C <br /> Point response Access Control Interface Module,the control panel <br /> • Selectable point response time <br /> • Selectable EOL values and configuration provides a fully supervised access control solution. <br /> Cross point capability The solution offers 14 programmable levels of access <br /> •• Fire alarm verification authority.Authority for door access is controlled by <br /> • Dangerous gas indicator includes carbon monoxide the user level,the group of the user,the time of day, <br /> (NFPA 720) the door state, and the area armed (On/Off) state. <br /> • Watch mode Easy exit control <br /> • 63 point indexes The control panel changes from one On (armed) state <br /> User interface to another without turning off(disarming) the system. <br /> • Supervision of up to 32 keypads For example, if you change the state from Part On <br /> • Custom keypad text is fully programmable through (Perimeter Arm) to All On (Master Arm),the control <br /> RPS panel complies and reports the change. Easy Exit <br /> • Full function menu including customizable shortcuts Control reduces the number of keystrokes, simplifying <br /> • Authority by area and 32 character name for each system operation. <br /> user <br /> • 14 custom authority levels to restrict system features Programmable passcode-controlled menu list <br /> that each user can access Passcode-controlled shortcuts provide users only with <br /> • Programmable primary and secondary language by the options and information pertinent to them, <br /> user and keypad;select from English, Spanish, simplifying system operation. <br /> French,and Portuguese Flexible control <br /> Area configurations The system provides the flexibility to choose added <br /> Link multiple areas to a shared area such as a lobby or convenience or high security. For example, you can <br /> common entryway.The shared area then automatically restrict to a keypad's immediate local area turning on <br /> turns On (arms) when all associate areas are armed (arming) and turning off(disarming) the system with a <br /> and turns Off(disarms) when any one associate area passcode, even if the user has access to other areas. <br /> is disarmed. For higher security applications,the Area This is particularly useful for high security areas, <br /> Re-Arm feature guarantees that areas are always where a user may have access to the area, but would <br /> rearmed,and are disarmed for no longer than a prefer to only turn off(disarm) the area individually <br /> specific, configurable,amount of time (for example, rather than with the rest of the system. <br /> service time). Monitor Delay/Delayed Response <br /> Custom functions Create a special point index that delays the reaction of <br /> For added convenience,the installer can program a point for a specified time (up to 1 hour in minutes <br /> custom functions that allow customers to complete and seconds). This delay provides time for the <br /> complex tasks with one simple action. For example,a specified condition to reset before activating any <br /> custom function can bypass a group of points and arm annunciation.The system can annunciate locally and <br /> the system, allowing the user to perform these send a report, if desired. When the system is armed, <br /> functions with one easy command. Users can activate the point can respond like a normal point— providing <br /> custom functions with a keypad, keyfob,token, or dual functionality. Use this feature to ensure that <br /> card, or the control panel can activate a function in perimeter doors have not been propped open, or to <br /> reaction to a faulted point, or automatically through a monitor critical areas such as computer rooms and <br /> scheduled event (SKED). safes,for example. <br /> Passcode security System users <br /> • Two-man rule. Requires two people with two unique The system supports up to 2,000 users. Each user can <br /> passcodes to be present at the time of opening. have a personalized passcode, a wireless keyfob, and a <br /> • Early ambush.Allows users to verify that the facility is credential to control the system.You can assign <br /> safe by requiring two passcodes.The control panel passcodes to one of 14 customized authority levels in <br /> sends a duress event if the user does not enter the each area that can be restricted to operate only during <br /> passcode a second time after inspecting the certain times.You can program a primary and <br /> premises. secondary language for each user and by keypad <br /> • Dual authentication.Requires two forms of (select from English, Spanish, French,and <br /> identification before processing certain system <br /> Portuguese).The keypad changes to the user's <br /> commands, including turning off the system and programmed language when the user enters his <br /> passcode or holds the Help key. <br />