10011 EVERGREEN WAY 2023 HOBBY LOBBY Plans 2025-03-18
>
Address Records
>
EVERGREEN WAY
>
10011
>
HOBBY LOBBY
>
Plans
>
10011 EVERGREEN WAY 2023 HOBBY LOBBY Plans 2025-03-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 7:53:37 AM
Creation date
3/14/2025 3:39:25 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10011
Tenant Name
HOBBY LOBBY
Permit
FA2304-007
Year
2023
Notes
UPGRADE EXISTING FACP AND ADDITION OF CELLULAR SOLE PATH COM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 I B9512G Control Panels <br /> Communication formats Bosch Remote Connect(Cloud) <br /> The control panel prioritizes and sends reports to four Remote Connect simplifies connections from RPS,and <br /> route groups. Network and phone communications can the Remote Security Control app, using Bosch Cloud <br /> use one of two communicationformats: <br /> form s. Modem4, services.This service creates a secure connection to <br /> Contact ID. Each group has a programmable primary the control panel without specific router settings or <br /> and backup destination. the need for a static IP address or DNS. <br /> The control panel provides flexible communications for <br /> most central stations with reporting capabilities such • Notice <br /> as: 1 <br /> The Bosch Remote Connect service is not <br /> • Individual point numbers available in Europe,the Middle East,or Africa. <br /> • Opening or closing reports by user and area number <br /> • Remote programming attempts <br /> • Diagnostic reports Firmware updates <br /> The system allows remote firmware updates: <br /> • Control panel updates. Remotely update the control <br /> 1 Notice panel firmware for easy feature enhancements <br /> — For premises equipment used in the without replacing ROM chips. <br /> communication path,such as routers, use only UL • Module update support. Remotely update the <br /> listed equipment. firmware on connected SDI2 modules for easy feature <br /> enhancements without visiting each individual <br /> IP communication module. <br /> The control panel can use IP to communicate with a Firmware updates occur through Remote Programming <br /> Conettix D6600 or a Conettix D6100IPv6 Software (RPS) and the RPS Firmware Update Wizard. <br /> Communications Receiver/Gateway. Use one of the The Firmware Update Wizard uses the on-board USB <br /> following for IP: connection or the on-board Ethernet (IP) connection <br /> • The on-board Ethernet connection (the on-board (the on-board Ethernet port is excluded on "E" <br /> Ethernet port is excluded on"E"versions). versions) to transfer firmware updates. <br /> • A B426. The control panel can optionally receive firmware <br /> • A plug-in cellular communicator(B440/B440-C/B441/ updates from RPS. Use one of the following <br /> B441-C/B442/B443/B444). communication methods: <br /> Conettix IP communication provides a secure path that • B426 <br /> includes anti-replay/anti-substitution features, and • Plug-in cellular communicator: B440/B440-C/B441/ <br /> enhanced security with up to AES 256-bit encryption B441-C/B442/B443/B444 <br /> (using Cipher Block Chaining (CBC)). <br /> The control panel supports Domain Name System •• Notice <br /> (DNS) for both remote programming and central Data rate apply <br /> station communication. DNS provides ease of use, Cellular firmware updates require more time than <br /> eliminating the need to use static IP addresses as your Ethernet updates and carrier data rates apply. <br /> reporting destination,and accommodates a simple <br /> solution for central station disaster recovery.The A wide variety of input options <br /> control panel supports both IPv6 and IPv4 networks. Each point: <br /> Communication paths • Single 1 ko, single 2 ko,dual 1 kG(1 kG+1 kG),and <br /> The control panel accommodates up to four separate No EOL (end-of-line) (EOL) resistor options (for on <br /> phone and four separate network paths to the central board and B208 inputs) <br /> • <br /> station receiver.When resetting alarms or turning a Programmable for Fire, Intrusion,Access,Gas,and <br /> system on and off, the user is identified by name and Supervisory devices <br /> • Supports hardwired and wireless devices <br /> number. • Supports IP cameras by Bosch as point and output <br /> Personal notification devices <br /> The control panel can send text messages and emails IP camera support <br /> for personal notification over Ethernet or using a The control panel can integrate directly with Bosch IP <br /> cellular communicator.You can configure up to 32 cameras, using them as fully supervised points and <br /> destinations using a combination of cellular phone outputs. <br /> numbers and email addresses.The control panel sends <br /> Integration of cameras allows the camera's video <br /> notifications in the user's programmed primary motion detection to activate points on the control <br /> language. <br /> panel.The control panel's virtual outputs can be <br /> configured to trigger camera actions, including <br /> sending video snapshots via email. <br />