• <br /> EXPERIENCE THE CARLISLE DIFFERENCE 4RLISLE <br /> SYNTEC SYSTEMS <br /> Sure-Weld TPO <br /> I Reinforced Membrane <br /> Typical Properties and Characteristics LEED Information <br /> ASTM D6878 45-mil 60-mil 80-mil Extra Pre consumer Recycled Content 10% <br /> Physical Property Requirement (1.14 mm) (1.52 mm) (2.03 mm) Post-consumer Recycled Content 0% <br /> Tolerance on Nominal Thickness,% +15,-10 ±10 ±10 ±10 Manufacturing Location Senatobia,MS <br /> ASTM D751 test method T UT <br /> Caarlislrlisl e,PA <br /> Thickness Over Scrim,in.(mm) 0.015 min 0.018 typical 0.024 typical 0.034 typical - <br /> - <br /> ASTM D7635 optical method,average (0.380) (0.457) (0.610) (0.864) Solar Reflectance Index(SRI) 99(white)86(tan) <br /> of 3 areas <br /> Breaking Strength,lbf(kN) 220(976 N) 225(1.0)min 250(1.1)min 350(1.6)min <br /> ASTM D751 grab min 320(1.4)typical 360(1.6)typical 425(1.9)typical Radiative Properties for Cool <br /> Elongation Break of Reinforcement,% 15 min 15 min 15 min 15 min Roof Rating Council (CRRC) <br /> ASTM D751 grab method 25 typical 25 typical 25 typical <br /> Tearing Strength,lbf(N) 55(245)min 55(245)min 55(245)min 55(245)min and LEED - <br /> ASTM D751 proc.B 8 in.x 8 in. 130(578)typical 130(578)typical 130(578)typical Test White Tan Gray <br /> Brittleness Point,°F(°C) -40(-40)max -40(-40)max -40(-40)max -40(-40)max Method TPO TPO TPO <br /> ASTM D2137 -50(-46)typical -50(-46)typical -50(-46)typical <br /> Linear Dimensional Change,% ±1 max ±1 max ±1 max ±1 max CRRC- ASTM 0.79 0.71 0.46 <br /> initial solar C1549 <br /> ASTM D1204,6 hours at 158°F -0.2 typical -0.2 typical -0.2 typical <br /> reflectance <br /> Ozone Resistance,no cracks 7X ASTM PASS PASS PASS PASS CRRC-Solar ASTM 0.70 0.64 0.43 <br /> D1149,100 pphm,168 hrs reflectance after C1549 <br /> IN Exposure(Xenon Arc),no cracks PASS PASS PASS PASS 3 years (uncleaned) <br /> 7X ASTM G155,min. CRRC-Initial ASTM 0.90 0.86 0.89 <br /> exposure 10,080 kJ/m2 thermal emittance C1371 <br /> (4,000 hrs-0.70 W/m2) <br /> Water Absorption Resistance,mass% ±3.0 max ±3.0 max ±3.0 max ±3.0 max CRRC-Thermal ASTM 0.86 0.87 0.88 <br /> emittance after C1371 <br /> ASTM D471 top surface only 166 hours 0.90 typical 0.90 typical 0.90 typical <br /> 3 years (uncleaned) <br /> at 158°F water <br /> Factory Seam Strength,lbf(N)ASTM 66(290)min 66(290)min 66(290)min 66(290)min LEED-Thermal ASTM 0.90 0.86 0.85 <br /> emittance E408 <br /> D751 grab method <br /> Field Seam Strength,Ibfl Reefln(kN/m) No requirement 25(4.4)min 25(4.4)min 40(7.0)min SRI-Ifl ASTM 99 86 52 <br /> ASTM D1876 tested in peel 50(8.8)typical 60(10.5)typical 70(12.3)typical (Solar Rectance E1980 <br /> Index) <br /> Water Vapor Permeance,Perms No requirement 0.10 max 0.10 max 0.10 max SRI-3 year aged 85 77 49 <br /> ASTM E96 pros.B 0.05 typical 0.05 typical 0.05 typical (Solar Reflectance <br /> Puncture Resistance,lbf(kN) No requirement 250(1.1)min 300(1.3)min 400(1.8)min Index) <br /> FTM 101 C,method 2031(see 325(1.4)typical 350(1.6)typical 450(2.0)typical <br /> supplemental section) <br /> Properties After Heat Aging <br /> ASTM D573,32 weeks®240°F or PASS PASS PASS PASS Radiative Properties (Initial) <br /> 8 weeks CO 275°F No cracking No cracking No cracking No cracking for Special Colors <br /> No cracking when bent around 3" ±1.5 max 1.0 max 1.0 max 1.0 max <br /> diameter mandrel Reflectance Emittance SRI <br /> Weight Change,% Medium Bronze _0.28 0.86 29 <br /> Typical Weights Ib/fte(kg/m2) 0.25 0.33 0.45 Rock Brown 0.25 0.87 26 <br /> Slate Gray 0.38 0.87 42 <br /> Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. <br /> This data and information is intended as a guide and does not reflect the specification range for any particular property of Terra Gotta 0.25 0.86 25 <br /> this product. Patina Green 0.25 0.88 25 <br /> Solar Reflectance Index(SRI)is calculated per ASTM E1980. <br /> The SRI is a measure of the roof's ability to reject solar <br /> Oink- eo ICC ® .;; ,,a r::, heat,as shown by a small temperature rise.It is defined so <br /> ® ' that a standard black(reflectance 0.05,emittance 0.90)is <br /> CIt C 0 and a standard white(reflectance 0.80,emittance 0.90) <br /> APFBOVED >`�° n ® is 100.Materials with the highest SRI values are the coolest <br /> choices for roofing.Due to the way SRI is defined,particularly <br /> ��°r' hot materials can even take slightly negative values and <br /> hAlAtkll-DAOE COO /1 <br /> NtY USA- 2.up+ � t particularly cool materials can even exceed 100. <br /> UNWED �i '-A <br /> ��fa1`4 <br /> 800-479-6832 I P.O.Box 7000 I Carlisle, PA 17013 I Fax:717-245-7053 I www.carlislesyntec.com <br /> 07.26.23©2023 Carlisle. Carlisle,Sure-Weld,OctaGuard XT,and APEEL are trademarks of Carlisle. <br /> REPRINT CODE:600515 TPO-2012-"Sure-Weld TPO Reinforced Membrane Product Data Sheet" LEED is a registered trademark of the U.S.Green Building Council. <br />