Laserfiche WebLink
NOTES <br /> PROPOSED POWER PROTECTNE CABINET CHARLES NtfIRAKK CABINET THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED SHORT CIRCUIT <br /> 120/240V, 1 PH,SERVICE RATED, ABB INFlNITY DC PLANT EQUIPMENT EE LECTRICAL CALCULADONS AND THE MCRATINGS brbFOR <br /> EACH DEVICE IS ADEQUATE TO PROTECT THE • <br /> UTILITY SERVICE ENTRANCE OVERALL IA LISTED POWER CENTER, V/ <br /> IYY9 EXISTING 120/240 120/240 VAC 1Fl1[ N3R,85K/10K KE THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED VOLTAGE DROP <br /> TRANSFORMER N/3W, <br /> UTILITY COMPANY CALCULATIONS AND ALL BRANCH CIRCUIT AND FEEDERS COMPLY WITH THE NEC <br /> BACKUP MC <br /> MAIN BREAKER WITH (LISTED ON T-1)ARTICLE 210.19(A)(1)FPN NO. 4. 4111, sh <br /> GENERATOR 2OOA 200A INTERLOCKED GENERATOR <br /> r )PROPOSED THE(2)CONDUITS WTTH(4)CURRENT CARRYING CONDUCTORS EACH,SHALL APPLY <br /> II NEW WIRE AND CONDUIT PER UTILITY GEN PLUG FEED. 200A 65K INCAIC 0.75'DST CONDUITSTHE ADJUSTMENT FACTOR OF 80%PER Q <br /> N r 2020NEC TABLE 310.15(C 1) FOR UL10054 17 NEC TABLE 310.15(B)(3)(a)OR r/t��Wi�i- <br /> COMPANY REQUIREMENTS SURGE SUPPRESSIONSHD/ <br /> 03 DEVICE 100KA SAD/AIOV /12 FOR 15A-20\/1P BREAKER:0.8 x 30A- 24.0A 5701 SOUTH SANTA FE DRIVE <br /> ABA <br /> 01 0 /10 FOR 25A-30A/2P BREAKER:0.8 x 40A- 52.OA LITTLETON, CO 80120 <br /> GFq 151 to PROPOSED 2/10, 1 /ID CU CND. <br /> •FOR RECDFlER 1 /B FOR 35A-40A/2P BREAKER:0.8 x MA- 44.OA <br /> NEW 200A, 120/240V, 1+3W,SERVICE RATED, 1� 03 01 C /B FOR 45A-60A/2P BREAKER:0.8 x 75A= 60.0A <br /> FUSIBLE DISCONNECT(RDA 3R). <br /> 06 <br /> (SQUARE D MODEL No.0224NR61/OR EOUNALENT). SPAS Era PROPOSED 2#10 CONDUIT SIZING:AT 401E FILL PER NEC CHAPTER 9,TABLE 4,ARTICLE 358. <br /> VERIFY COMPATIBILITY WITH LOCAL miry COMPANY. 07 P� ti :FOR RECTIFIER 2 <br /> LOCATION OF MAIN BONDING JUMPER. SPACE <br /> CONDUIT-0.122 SQ.N AREA <br /> SPACEIl 09 10 0.75'CONDUIT-0.213 SO. N AREA <br /> PROPOSED 2/10, 1 #10 CU CND. 2.0' CONCUR- 1.316 SQ.N AREA <br /> SPACE 11 12 tillWTMSPACE n I FOR RECTIFIER 3 3.0' CONDUIT-2.907 SQ.N AREA . O <br /> 13 14 CABINET CONVENIENCE OUTLET CONDUCTORS(1 CONDUIT): USING THWN-2,CU. OA <br /> (3)3/0 /6 GROUND 0 4a PROPOSED 2#10 1 FOR RECTIFIER 4 <br /> CU(GROUNONG IN 3"Sql 40 CONDUIT SPACE <br /> ELE.i Null CONDUCTOR) 15 16 V /10- 0.0211 50. N%2 - 0.0422 S0. IN <br /> 11 SPACE 17 16� /10- 0.0211 50. N X 1 -0.0211 SQ. IN <GROUND <br /> SPACE SPACE TOTAL - 0.0633 S.O. IN <br /> 1000 HOLCOMB WOODS PKWY, <br /> _,,,-.,,11,,--,_ (1)PROPOSED SUITE 210 <br /> /� SPACE 21 SPACE 0.5"EMT CONDOR 0.5'EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF(3)WIRES, ROSWELL, GA 30076 <br /> GROUNDING ELE0 1 CI) SPACE 4 SPACE NCLUDING GROUND WBR,AS INDICATED ABOVE. 678-280-2325 <br /> (2)5/8'0 X IS LONG - SPACE SPACE RECTIFIER <br /> CCNCTCRS (2 CONDUITS): USNG UL1015,CU. <br /> MOUND ROO SPACED PROPOSED 2/10, 1 /10 CU CND. 0 <br /> MINWM 6'APART FOR CONVENIENCE OUTLET /10 - 0.0266 SO. IN X 4-0.1064 SO. IN <br /> #10- 0.0082 SO. IN% I -0.0082 SQ. IN <BARE GROUND <br /> TOTAL -0.1146 50. IN WILErO`r <br /> CONTRACTOR TO REFER TO BRANCH CIRCUIT WIRING SUPPLYING RECTIFIERS ARE TO BE RATED UL101S, 105'C,600V,AND PVC INSULATED,IN THE SIZES SHOWN 0.75'EAR CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF(5)WIRES, a <br /> FINAL URUIY DESIGN DETNLS IN THE ONE-UNE DIAGRAM.CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR THWN-2 FOR CONVENIENCE OUTLET BRANCH CIRCUIT. NCLUDING GROUND WIRE,AS INDICATED ABOVE, l+411+ 'Oh <br /> BREAKERS REQUIRED: (OR EOUNALENT MANUFAL'TURERl PPC FEED CONDUCTORS(1 CONDUIT): USING TF1WN,CU. LI DIY 1. �__, <br /> (4)30A,2P BREAKER -SQUARE D P/N:00230 <br /> (2) 15A, IP BREAKER -SQUARE D P/N:00115 3/0-0.2879 SO.IN X 3-0.8037 S0. IN <br /> #6 -0.0507 S0.IN X 1 -0.0507 S0. IN <GROUND <br /> TOTAL -0.8544 50. N 1 s�s _ 9 <br /> 3.0"SCH 40 PVC CONDUIT IS ADEQUATE TO NCLUd GROUND WRE,AS INDICATED ABOVE,HANDLE THE TOTAL OF(4)WIRES, �St AL° <br /> 0 OPTIONAL A.UMINW SERVICE CCNOUCTGR: 04/20/2022 <br /> •4/O AL+/2 CARD MAY BE USED INSTEAD OF 3/0 CU♦/6 SRO IF THE TOTAL <br /> LENGTH Of THE CODUCIOR IS LESS T14NI 200 FT FROM 11E TRwsSINER. UBI NUMBER: 604-106-184 <br /> •ALUMA.M CONDUCTORS MIST IN 97C TO CARRY TIE FULL 20114 LOAD REWIRED <br /> •ALUIS&M TO(Depot IA15 WMECTIONS MIST MEET A110 CONFORM To ma AND R IS A"CUT"SF LAW FOR ANY PERSON. <br /> BE IA.LISTED USE,W11 CORROSPON CODUCIM LUBRICANT ON CONNECTIONS UNLESS THEY ARE ACTING UNDER THE DIRECTION <br /> OF A LICENSED PROFESSIONAL ENGINEER. <br /> TO ALTER TINS DOCUMENT. <br /> DRAWN BY: CHECKED BY:APPROVED BY. <br /> MALT RM MSB <br /> REDS REV#: --- <br /> PPC ONE-LINE DIAGRAM NO SCALE 1 <br /> CONSTRUCTION <br /> DOCUMENTS <br /> PROPOSED CHARLES PANEL SCHEDULE SUBMITTALS <br /> VOLT AMPS VOLT AMPS REV DATE DESCRIPTION <br /> LOAD SERVED (WATTS) TRIP Cd PHASE CDT TRIP (WATTS) LOAD SERVED A 04/11/2022 EN=I'OR NMI <br /> L1 L2 LI L2 <br /> PPC GFCI OUTLET 160 15A 1 /L A 2 30A 2880 ABB/GE INFRWTI' 0 0A/26/2022 ISSUED FOR O]1*1AL1e110N <br /> CHARLES GFO OUTLET • 180 1S1 3✓r. 5 1 4 2880 RECTIFIER 1 <br /> -SPACE- 57✓'.- A 6 3°A 2880 AB/GE ItFRNIY <br /> -SPACE- - - -7•-ti 8 6 2880 RECTIFlER 2 <br /> -SPACE- 9 al. A 10 2880 ABB GE INFNm <br /> -SPACE- 11�. B 12 30A 2880 RECTIFIER 3 - <br /> -SPACE- 13-,- A 14 30A 2880 ABB/GE INFINITY <br /> -SPACE- 15"/N.• 8 15 2860 RECTIFIER <br /> -SPACE- 17-/L A -ti 16 -SPACE- <br /> -SPACE- 19-,- B ./-1-20 -SPACE- 1 A&E PROJECT NUMBER <br /> -SPACE- 21 Lc,- A n 22. -SPACE- <br /> -SPACE- 23-/L B _n_24 -SPACE- 22CCDO5N-0032 <br /> 2O0TAGE AMPS SPADE, <br /> 111520 111520 DISH Wireless L.L.C. <br /> 200A NCB, 1+,24 120 46V Lt L2 <br /> MB RATING: 65,000 AC 11700 11700 VOLTAGE AMPS <br /> 98 88 AMPS PROJECT INFORMATION <br /> 98 MAX AMPS <br /> 123 MAx 125% SESEA00105B <br /> 2408 39th ST <br /> EVERETT, WA 98201 <br /> SHEET TITLE <br /> ELECTRICAL ONE-LINE, FAULT <br /> CALCS & PANEL SCHEDULE <br /> SHEET NUMBER <br /> E-3 <br /> PANEL SCHEDULE NO SCALE 2 NOT USED ND SCALE 3 <br />