PROPOSED - — <br /> BUSSTEROO <br /> INSUL BARS PROPOSED 4'x12'xt/4'TINNED • EXOTHERMIC CONNECTION eT ItNNSPECTONND SLEEVE WITH <br /> TEST WELL COPPER GROUND BUSSBAJ1 • <br /> ■ MECHANICAL CONNECTION <br /> ♦ - - �B AWG STRANDED 4 INSULATED v <br /> (�•%(I) I I I GROUND BUS BAR <br /> A <br /> i - /2 ARID SOLID COPPER TINNED <br /> OGROUND ROD <br /> BOND PROPOSED EQUIPMENT I •\ BU55 BAR INSULATOR dvirsh- <br /> PAD TO PROPOSED \ I <br /> /GROUNDING ELECTRODE 5701 SOUTH SANTA FE DRIVE <br /> STSIEM (TYR. 4) _� _ _. }JJJ� \ GROUNDING LEGEND UTTLETON, co 80120 <br /> BO A0 H-FRAME POST TO �: 7 I EXISTING TOWER GROUND <br /> UNI-STRUT(TYP.) \ RING(FEILD VERIFY) 1. GROUNDING IS SHOWN DIAGRAMMATICALLY ONLY. <br /> I _' , - - BOND ICE BRIDGE • <br /> • SUPPORT POSTS TO 2. CONTRACTOR SHALL GROUND ALL EQUIPMENT AS A COMPLETE STSILM.GROUNDING SHALL BE IN <br /> GROUND RING BOND(s) • -----� <br /> '� COMPLIANCE WITH NEC SECTION 250 AND DISH Winless LLC.GROUNDING AND BONDBONDINGy/, f • " I (TIP ALL POSTS) REQUIREMENTS AND MANUFACTURER'S SPECIFICATIONS. <br /> II <br /> / '\r EXISTNG MONOPOLE <br /> \ <br /> #2 AWG BURIED GROUND 3. ALL GROUND CONDUCTORS SHALL BE COPPER;NO ALUMINUM CONDUCTORS SHALL0 <br /> BE USED. • , <br /> RING 30'BELOW GRADE . 1M] ____ i \ O <br /> #2 TINNED SOLD IN 1/2' <br /> 1000 HOLCOMB WOODS PKWY, <br /> MN. LIQUID TIGHT CONDUIT al GROUNDING KEY NOTES SUITE 210 <br /> FROM 24'BELOW GRADEA I ROSWELL, GA 30076 <br /> S. 678-280-2325 <br /> TO WITHN 3'TO 6'OF ° • • " ■r—'� <br /> CAD-WELD TTRMMMTION ® O F%TFRIOR(0701 INT/RING' #2 AWG SOLID COPPER,BURIED AT A DEPTH OF AT LEAST 30 INCHES BELOW <br /> POINT.EXPOSED ENO OF r —• — GRADE. OR 6 INCHES BELOW THE hNVST LIVE AND APPROXIMATELY 24 INCHES FROM THE EXTERIOR WALL <br /> THE LIQUID TIGHT CONDUITOR FOOTING. <br /> MUST BE SEALED WITH •? `� / <br /> SII"I E ALA' ) \ B TOWER GROUND RING;THE GROUND RING SYSTEM SHALL BE INSTALLED AROUND AN ANTENNA TOWERS LEGS, <br /> AND/OR CLAY ANCHORS.WHERE SEPARATE STD RMS HAVE BEEN PROVIDED FOR THE TOWER AND THE cystF9 OA <br /> \ / BUILDING.AT LEAST TWO BONDS SHALL BE MADE BETWEEN THE TOWER RING GROUND SYSTEM AND THE ,w -!' <br /> BUILDING MG GROUND STSILM USING MINIMUM l2 AWG SOUD COPPER CONDUCTORS. s 4 <br /> 4. <br /> 6-___ <br /> — —� — — 4\__ — \ __ / INTERIOR GROUND RING: i2 AWG STR/MUED GREEN INSULATED COPPER CONDUCTOR EXTENDED AROUND THE N Nl p�•j. <br /> O PERIMETER OF THE EQUIPMENT AREA.ALL NON-TELEC01tl1UMGT10NS RECITED METAWC OBJECTS FOUND _ �_.- <br /> 80N0 E PMENT AS WITHIN A SITE SHALL BE GROUNDED TO THE INTERIOR GROUND RING WITH 15 AWG STRANDED GREEN _ - <br /> REQUIRED BY MANUFACTURER INSULATED CONDUCTOR. IN <br /> "/2 <br /> PROPOSED EQUIPMENT GROUND RING TO O jW{11 TO INATTERIORLEAST GRIXGRII <br /> ATFOU RINGOH#2 AWG <br /> THE SOUD TINNNTERK)RED U GROUNDfirER WIRE LOCA PRIMARY N TED AT THE BONDS SHALL BE OF THE \�j$I$f�O sj`5919A. i <br /> EXISTING TOWER GROUND RING(TOTAL 2) BUILDING.PROVIOED R POINTS RIG, CORERS O <br /> Art stye <br /> GROUND ROD:UL LISTED COPPER CLAD SILEL MINIMUM 1/2 DANETER BY EIGHT FEET LONG.GROUND o4I2GI2D22 <br /> TYPICAL EQUIPMENT GROUNDING PLAN NO SCALE 1 E RODS SHALL BE INSTALLED WITH INSPECTION SLEEVES.GROUND RODS SHALL BE DRIVEN TO THE DEPTH OF <br /> GROUND RING CONDUCTOR. UBI NUMBER: 604-106-184 <br /> NOTES O CFI I RFFFRFNCF_GR1AIHLBM• POINT OF GROUND REFERENCE FOR ALL COMMUNICARONS EQUIPMENT R IS A VIOLATION OF LAW FOR ANY PERSON, <br /> FRAMES.ALL BONDS ARE MADE WON#2 AWG UNLESS NOTED OTHERWISE STRANDED GREEN INSULATED UNLESS rLO ARE ACTINGF UNDER THE DIRECTION <br /> OF A LICENSED PROFESSIONAL ENGINEER, <br /> PROPOSED UPPER TOWER --- ANTENNAS AND OVP SHOWN ARE GENERIC AND NOT COPPER CONDUCTORS.BOND TO GROUND RING WITH (2) /2 SOLD TINNED COPPER CONDUCTORS. TO ALTER THIS DOCUMENT. <br /> GROUND BUSS BAR REFERENCING TO A SPECIFIC MANUFACTURER.THIS <br /> LAYOUT IS FOR REFERENCE PURPOSES ONLY HATCH PLATE INO RAR• BOND TO THE INTERIOR <br /> GROUND RING WITH TWO l2 AWG STRANDED GREEN DRAWN BY: CHECKED BY:APPROVED BY: <br /> -- �- -- O CJTM <br /> INSULATED COPPER CONDUCTORS.WHEN A HATCH-PLATE AND A CELL REFERENCE GROUND BAR ARE BOTH <br /> - 3 \\-\\\\IN=\ PRESENT,TR#CHGa MUST BE CONNECTED TI THE HATCH-PLATE MD CT THE MERgR GROUND RING IMAM RM MSB <br /> • e USING (2)Tw0 /2 AWG STRADED GREEN NSULATED COPPER CONDUCTORS EACH. <br /> + RIDS REV #: --- <br /> A \ III \\�•' P \v. H RIOT AR F NTRY PORT ND BARS:LOCATED AT TIE ENTRANCE TO THE CELL SITE BUILDING. BOND <br /> \\\\\\_.V\�•\•N \\\\ \\\ \\ O TO GROUND RING WITH A l2 AWG SOLD TINNED COPPER CONDUCTORS WITH AN EXOTHERMIC WELD AND <br /> � ,/ \\\\\\\\0\\ \\\ PRLTPosED n Awc INSPECTION SLEEVE. CONSTRUCTION <br /> \O\O\\\\\\\O\J\Q Q\\\\\\\O\\\\O STRANDED COPPER <br /> �:\\ o\oo\o\\o\\o\\..� GREEN INSULATED(TP) ODOCUMENTS <br /> I TELCO GROIINn BAR BOND 10 BOTH CELL REFERENCE GROUND BAR OR EXTERIOR GROUND RING. <br /> PROPOSED 4'x6'z1 4'DINED e\\O�\\I\\\\`..'\. \\\\\`\\\W`\\\`\.' FRAME BONDING THE BONDING POINT FOR TELECOM EQUIPMENT FRAMES SHALL BE THE GROUND BUS THAT SUBMITTALS <br /> / \\V\\`QO\\\\\\ \\` .....- \\\\\\\\ O IS NOT ISOLATED FROM THE EOUIPMEMS METAL FRAMEWORK. <br /> COPPER SECTOR GROUND ' `•p\\\ \\\Nlv,-\ \\\\\\\\\\\\\\\\�\ REV DATE DESCRIPTION <br /> BUSS BAR(TIP OF(3)) \V•'p\\��\q 0 \\\\\\ \\\\\\\\ <br /> i f \••••• \\T7: ►\ \\\\\\ \\\\\ OK INTERIOR UNIT BONDS: META FRAMES, CABINETS AND INDMIXYL META LIC UNITS LOCATED WITH THE AREA A BA/1T/1II4 mlIN 1011 RESEW <br /> ,�\\\\\\\\\\v\,\`I\\� ��R �r• ,� \\\\\\\\\\\\\\\\\\\\\\\ OF THE INTERIOR RING.GROUND RING REQUIRE A/6 AWG STRANDED GREEN INSULATED COPPER BOND 70 THE o 04/20/2072 ISM=FOR OONIIINOTgI <br /> ` •s 0 \\\\\�\\\\\V �'. I \\\\\\\\\ \\\\\\ \\ y, INTERIOR GROUND RING. <br /> \\\\\\ \ \\\\\\\\\\\\\\\\\\. — <br /> •�i \\\\ \\\•`� / \ / G \\\ \\\Q\ \\� i LO FENCE AND GATE CANN WRING. METAL FENCES I.BE 7 FEET OF THE E t GROUND RING OR OBJECTS <br /> O\;\\ \�\\O\\. BONDED TO THE EXTERIOR GROUND RING SHALL BE BONDED TO THE GROUND RING WITH A/2 AWG SOLD <br /> \\\O Q\ <br /> \\.;•: I \\\ \\ TINNED COPPERID CONDUCTOR AT AN OPENINGS. <br /> INTERVAL NOT EXCEEDING 25 FEET. BONDS SHALL BE MADE AT EACH <br /> . ' I I\\\\\ GATE POST ARID ACROSS GATE OPENINGS. <br /> �\;. 1\ /I I I \\� <br /> PROPOSED GROUND ,` I O EXTERIOR LAITY BONDS:METAWC OBJECTS, EXTERNAL TO ORc MOUNTED TO THE BUILDING,SHALL BE BONDED AWE PROJECT NUMBER <br /> BUSS BM _ \ I\� I \ TO THE EXTERIOR GROUND RING.USING�2 TINED SOLID COPPER WIRE <br /> INSULATORS(TYP) �j -- <br /> � <br /> 22CCDO5N-0032 <br /> `/ .•\ / ' \ \' p <br /> ON ICE BRNGF p PPORT,S•EACH ICE BRIDGE LEG SHALL BE BONDED TO THE GROUND RING WITH /2 AWG BARE <br /> \ TINNED COPPER CONDUCTOR. PROVIDE IXO1HERMIC WELDS AT BOTH THE ICE BRIDGE LEG MID BURIED DISH Wireless L.L.C. <br /> ��`! \\ �� \�lJ�, GROUND RING. PROJECT INFORMATION <br /> ;� \` �. <br /> I <br /> _ O DURING ALL DC POWER SrSIFJI CHANGES INCLUDING DC St0IW CHANGE OUTS, RECTIFIER REPLACEMENTS <br /> \\`:1:`�\\::�Q\\�p\\\\•A :\\\:\O\\�:\QI:Q\\. IN ALLATIONS, BREAKER E ST DCOC CHANGES, YSTEERYSHALADDITIONS.E EQUI D THAT <br /> SERVI AND SESE 3 t1 05B <br /> ``�"•\\\"•\\\\\••\�\\n v.\O O . • CONTRACTORSNS <br /> OR CHANGES TO DC COTNERTER ARE <br /> SYSTEMS IT DWV.L BE RETURN 2408 <br /> 39th ST <br /> \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\O\\\\\\ON\\\\\\\\\\\, . CONTRACTORS VERFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH A MASTER DC SYSTEM RERAN GROUND <br /> PROPOSED \\\\\\\\\\\\\\\\\\\\\\\\.\\yI\ \\\\\ \Q\ \\\\: CONDUCTOR FROM THE DC POWER STSILM COMMON RETURN BUS DIRECTLY CONNECTED TO THE CELL SITE EVERETT, WA 98201 <br /> AWG STRANDED \\ O\\O\\\\\\O\\\O\�• <br /> REFERENCE GROUND BAR <br /> COPPER \.•\\\..• •ILIA`•Q\\\\\�Q ..• O SHEET TITLE <br /> COPPER GREEN(TYP P TOWER TOP COLLECTOR BUSS BAR IS TO BE MECHANICALLY BONDED TO PROPOSED ANTENNA MOUNT COLLAR. <br /> INSULATED +4' GROUNDING PLANS <br /> i,a REFER TO DISH Winless LLC.GROUNDING NOTES. AND NOTES <br /> SHEET NUMBER <br /> G-1 <br /> TYPICAL ANTENNA GROUNDING PLAN NO SCALE 2 GROUNDING KEY NOTES No SCALE 3 <br />