My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2420 39TH ST 2022 DISH WIRELESS Plans 2025-03-18
>
Address Records
>
39TH ST
>
2420
>
DISH WIRELESS
>
Plans
>
2420 39TH ST 2022 DISH WIRELESS Plans 2025-03-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 11:09:14 AM
Creation date
3/18/2025 11:08:33 AM
Metadata
Fields
Template:
Address Document
Street Name
39TH ST
Street Number
2420
Tenant Name
DISH WIRELESS
Permit
B2205-010
Year
2022
Notes
INSTALL ANTENNA PLATFORM, (3) PANEL ANTENNAS, JUMPERS, ETC
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROUNDING NOTE& <br /> 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL • <br /> BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. r <br /> 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR d ...sh <br /> GROUND ELECTRODE SYSTEMS.THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO <br /> ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. <br /> 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO wireless. <br /> PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. <br /> 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY 5701 SOUTH SANTA FE DRIVE <br /> BONDING ACROSS THE DISCONTINUITY WITH /6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. UTTLETON, Co 80120 <br /> 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS <br /> WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS <br /> EQUIPMENT. <br /> 8. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL <br /> EQUIPMENT GROUND WIRES, /8 STRANDED COPPER OR LARGER FOR INDOOR B15; /2 BARE SOUD TINNED COPPER FOR OUTDOOR BTS. <br /> 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE <br /> OF THE GROUND BUS ARE PERMITTED. <br /> 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE /2 SOLID TINNED 1000 HOLCOMB WOODS PKWY, <br /> COPPER UNLESS OTHERWISE INDICATED. SUITE 210 <br /> 78-2 <br /> 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. RO 6 OA 30076 <br /> 78-280-2325 <br /> 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45 BENDS CAN BE ADEQUATELY <br /> SUPPORTED. <br /> 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. <br /> 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 600 <br /> 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. it <br /> 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND <br /> �� <br /> BAR. <br /> 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON AU.COMPRESSION AND BOLTED GROUND <br /> CONNECTIONS. <br /> 18. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 11' <br /> 17. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND <br /> RING, IN ACCORDANCE WITH THE NEC. ,./24/2022 <br /> 18. BOND ALL METALLIC OBJECTS WITHN 8 ft OF MAIN GROUND RING WITH (1) 12 BARE SOUD TINNED COPPER GROUND UBI NUMBER: 604-106-184 <br /> CONDUCTOR. IT IS A PORTION OF LAW FOR ANY PERSON. <br /> RECTION <br /> 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND UGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED OAF A LICENSED PROFESSIONAL ENGTHEY ARE ACTING UNDER'ME INEER <br /> THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR. SUCH AS METALLIC CONDUITS. METAL SUPPORT CUPS OR TO ALIOR 1 s DOCUMENT. <br /> METALLIC <br /> SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL <br /> DRAWN BY. CHECKED BY:APPROVED BY: <br /> CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e.. <br /> NONMETALLIC CONDUIT PROHIBITED BY LOCAL.CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. MAN RM MSB <br /> 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE#2 BARE SOLID TINNED COPPER IN 3/4" RFDS REV/: --- <br /> NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3"TO 8"OF CAD-WELD TERMINATION POINT. THE EXPOSED END <br /> OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). CONSTRUCTION <br /> 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE THE CONTRACTOR SHALL ROUTE DOCUMENTS <br /> TWO GROUNDING CONDUCTORS FROM THE ROOFTOP.TOWERS.AND WATER TOWERS GROUNDING RING,TO THE EXISTING GROUNDING <br /> STsiEM.THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO SUBMITTALS <br /> THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, UGHTNING PROTECTION sYs,eM,AND BUILDING MAIN WATER UNE REV DATE DESCRIPTION <br /> (FERROUS OR NONFERROUS METAL PIPING ONLY). DO NOT ATTACH GROUNDING TO FIRE SPRINKLER SYSTEM PIPES. A 04/11/11022 IMO FM IMO/ <br /> 0 04/25/2022 calm Fa O NSWAX1nel <br /> A&E PROJECT NUMBER <br /> 22CCDO5N-0032 <br /> DISH Wireless L.L.C. <br /> PROJECT INFORMATION <br /> SESEA00105B <br /> 2408 39th ST <br /> EVERETT, WA 98201 <br /> SHEET TITLE <br /> GENERAL NOTES <br /> SHEET NUMBER <br /> GN-5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.