Laserfiche WebLink
PV ,\LINK 1 J� STRING-1 (5 MODULES) <br /> — ---_ • THE 2020 WCEC 705.11 THE ADDITIONAL SUPPLY <br /> , SIDE SOURCE DISCONNECTING MEANS FOR THE <br /> r STRING-2(5 MODULES) PHOTO-VOLTAIC SYSTEM SHALL BE GROUPED <br /> I = 1 _ _ ��� WITH THE SERVICE DISCONNECTING MEANS FOR LUNSTRUM <br /> PVLINk THE STRUCTURE. ELECTRIC INC <br /> • THE EXTRA AC DISCONNECT IS MOUNTED NEXT <br /> TO THE MSP ON INTERIOR. CERTAINLY A BIT ODD 408 ESTATE DRIVE, <br /> STRING-3(6 MODULES) BUT WE HAVE TO ADD A REDUNDANT JACKSONVILLE,NC 28540-5129 <br /> PV LINK <br /> - — <br /> - i- - -_ '1 DISCONNECT INSIDE DUE TO CITY JURISDICTION. REVISIONS <br /> r � - - - _ - - - - <br /> PV MODULE DESCRIPTION DATE REV <br /> • THE EXTRA AC DISCONNECT IS MOUNTED NEXT TO REDESIGN 05/05/2023 A <br /> THE MSP ON INTERIOR REDESIGN 07/14/2023 B <br /> (6)#10AWG,PV WIRE <br /> (1)#6 AWG BARE COPPER-GND SNAPRS RAPID <br /> SHUTDOWN(TYP.) Signature with Seal <br /> TO UTILITY GRID <br /> L1 L2 N <br /> ClilBI-DIRECTIONAL UTILITY <br /> METER 1-PHASE,3-W, <br /> 120V/240V <br /> RAPID If DATE:01/05/2023 <br /> PROJECT NAME&ADDRESS <br /> SHUTDOWN (E)MAIN SERVICE PANEL, <br /> 200A RATED,240V <br /> GENERAC PWRcell: i <br /> SWITCH <br /> L J <br /> MODEL X7602 7600W ' <br /> (240V)OUTPUT:240V,32A <br /> 96.5%CEC WEIGHTED EFFICIENCY <br /> NEMA 3R RATED,UL 1741 LISTED, " <br /> INTERNAL GFDI WITH INTEGRATED (N)AC DISCONNECT: (E)MAIN BREAKER TO <br /> DC DISCONNECT 240V,60AMP /;� HOUSE 240 V,200A/2P <br /> NEMA 3R,UL LISTED, O ' 0— (TOP FED) <br /> LOCABLE AND 0 •• U <br /> ----1 NON-FUSIBLE N—N W <br /> . 40A/2P L L <br /> , ,<TN H < . <br /> 30A/2P U W N <br /> n oLOWER <br /> GENERAL .i <br /> -0 • W 0 < rn <br /> J ` Z <br /> L - - - CORE - - - - - -I - - I U W( <br /> 0 O I—J (3)#8 AWG THHN EXISTING GROUNDING W ELECTRODE SYSTEM- - - ,..., (1)#10AWGTHHNGND H5�\P � IN 3/4"EMT CONDUIT RUN �(4)#10G THWNF <br /> �Q ( z <br /> (1)#10 AWG THWN EGC <br /> IN 3/4"EMT CONDUIT RUN OOb (3)#8AWGTHHN <br /> (1)#10AWGTHHN EGC <br /> IN 3/4"PVC CONDUIT RUN <br /> (2)#10AWGTHHN _ <br /> (1)#10 AWG THHN EGC _ <br /> IN 3/4"PVC OR EMT <br /> CONDUIT RUN (N) COMUNICATION ^—� <br /> ill <br /> --J-� ROUTER O I O • <br /> LI �. SHEET NAME <br /> J <br /> ,.,1` INTERCONNECTION ELECTRICAL <br /> CIA 120%RULE-NEC 705.12(D)(2) <br /> BACK UP -0 o- LINE DIAGRAM <br /> LOADS UP TO —O UTILITY FEED+SOLAR BACKFEED SHEET SIZE <br /> 50A CIRCUIT 200A+40A=240A <br /> BUSS RATING x 120% ANSI B <br /> 200A x 120%=240A I I„ X 17" <br /> PROTECTED LOADS SERVICE PANEL CITY OF EVERET'i SHEET NUMBER <br /> 1 ELECTRICAL LINE DIAGRAM PWRcell MODEL 125A RATED, 240/120, 1-PHASE <br /> 6 BATTERY (50A/2-P MB) REVIEWED FOR PERM I PV-4 <br /> PV-4 SCALE: NTS 18 kWh, 9 kW <br />