1429 BROADWAY 2023 Plans 2025-03-18
>
Address Records
>
BROADWAY
>
1429
>
Plans
>
1429 BROADWAY 2023 Plans 2025-03-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 2:14:22 PM
Creation date
3/18/2025 2:13:47 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
1429
Permit
B2304-018
Year
2023
Notes
INSTALL 24 400-WATT SOLAR PANELS ON ROOF, 12KW BATT BACKUP
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SOLAR MODULE SPECIFICATIONS DC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: <br /> MANUFACTURER/MODEL# SEG SOLAR SEG 400 BMD-HV(400W) ARRAY TO OPTIMIZER : FROM INVERTER TO POI : <br /> MODULES <br /> VMP 30.81V EXPECTED WIRE TEMP(In Celsius) 34° No. OF INVERTER 2 LUNSTRUM <br /> IMP 12.99A TEMP. CORRECTION PER TABLE(310.15)(B)(2)(a) 0.96 EXPECTED WIRE TEMP(In Celsius) 34' ELECTRIC INC <br /> VOC 37.12V <br /> ISC 13.60A NO. OF CURRENT CARRYING CONDUCTORS 2 TEMP.CORRECTION PER TABLE(310.15)(B)(2)(a) 0.96 <br /> 408 ESTATE DRIVE, <br /> MODULE DIMENSION 67.80"L x 44.65"W x 1.38°D (In Inch) CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) 1.00 NO. OF CURRENT CARRYING CONDUCTORS 3 JACKSONVILLE,NC 28540-5129 <br /> CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) 1 REVISIONS <br /> CIRCUIT CONDUCTOR SIZE 10 AWG <br /> INVERTER SPECIFICATIONS CIRCUIT CONDUCTOR AMPACITY 40A CIRCUIT CONDUCTOR SIZE 8AWG DESCRIPTION DATE REV <br /> CIRCUIT CONDUCTOR AMPACITY 55A REDESIGN 05/05/2023 A <br /> MANUFACTURER/MODEL# GENERAL PWRCELL XVT076A03 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) REDESIGN 07/14/2023 B <br /> NOMINAL AC POWER 7.600 kW 21.25A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) <br /> NOMINAL OUTPUT VOLTAGE 240 VAC 1.25 X MAX DC OUTPUT CURRENT 40.00A <br /> 1.28 X MAX INVERTER OUTPUT CURRENT Signature with Seal <br /> NOMINAL OUTPUT CURRENT 32A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC(310.15)(B)(2)(a) <br /> DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC(310.15)(B)(2)(a) <br /> TEMP.CORRECTION PER TABLE(310.15)(B)(2)(a)X 38.40A <br /> AMBIENT TEMPERATURE SPECS CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a)X CIRCUIT TEMP.CORRECTION PER TABLE(310.15)(B)(2)(a)X 52.80A <br /> RECORD LOW TEMP -6° CONDUCTOR AMPACITY CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a)X CIRCUIT <br /> AMBIENT TEMP(HIGH TEMP 2%) 34° <br /> Result should be greater than(21.25A)otherwise less the entry for circuit conductor size and CONDUCTOR AMPACITY <br /> ampacity Result should be greater than(40.00A)otherwise less the entry for circuit conductor size and <br /> CONDUIT HEIGHT 0.5" ampacity <br /> ROOF TOP TEMP 56° DC CONDUCTOR AMPACITY CALCULATIONS: DATE 01/05/2023 <br /> CONDUCTOR TEMPERATURE RATE 90° FROM OPTIMIZER TO INVERTER: PROJECT NAME&ADDRESS <br /> MODULE TEMPERATURE COEFFICIENT OF Voc -0.260000 <br /> AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT +0° <br /> PER NEC 310.15(B)(2)(c) <br /> EXPECTED WIRE TEMP(In Celsius) 34`+0°=34° <br /> TEMP. CORRECTION PER TABLE(310.15)(B)(2)(a) 0.96 <br /> NO. OF CURRENT CARRYING CONDUCTORS 4 <br /> CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a) 0.80 0 <br /> CIRCUIT CONDUCTOR SIZE 10AWG r LJJ _ <br /> CIRCUIT CONDUCTOR AMPACITY 40A ~ Q 0 <br /> Uw } CO <br /> Lb U Q rn <br /> (REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) I I J - Z cf <br /> 30.00A <br /> 1.25 X MAX DC OUTPUT CURRENT w W Q <br /> C <br /> DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC(310.15)(B)(2)(a) G 0 0 ►- <br /> TEMP.CORRECTION PER TABLE(310.15)(B)(2)(a)X 30.72A D ct f- <br /> u) m L11 <br /> CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a)X CIRCUIT (L w <br /> CONDUCTOR AMPACITY I- Z W <br /> (A <br /> Result should be greater than (30.00A)otherwise less the entry for circuit conductor size and Z CND in <br /> ampacity <br /> D <br /> _J <br /> ELECTRICAL NOTES <br /> 1.)ALL EQUIPMENT SHALL BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br /> 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90°C WET ENVIRONMENT. <br /> 3.)WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS <br /> CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. <br /> 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. SHEET NAME <br /> 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEM. CONTRACTOR SHALL FURNISH ALL NECESSARY WIRING <br /> OUTLETS, SUPPORTS, FITTINGS , AND ACCESSORIES TO MEET APPLICABLE CODES AND STANDARDS. CALCULATIONS <br /> 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE SHEET SIZE <br /> THEM ACCORDINGLY. <br /> 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND ACCESSIBLE. ANSI B <br /> 8.) INSTALL MODULE AND RACKING GROUNDING HARDWARE PER MANUFACTURER'S INSTRUCTION. <br /> CITY OF EVERETT 11" X 17" <br /> RIB iEWED FOR PERMIT SHEET NUMBER <br /> N L PV-5 <br />