DN-3558:a1 •D-102 <br /> A M 8R ® NOTIFIER® <br /> Relay Module <br /> by Honeywell <br /> Annunciator Control Systems <br /> General <br /> The ACM-8R is a module in the Notifier ACS class of annuncia- <br /> tors.It provides the NFS2-3030,NFS-320, NFS2-640 and NCA-2, °`" - — ''. za <br /> Fire Alarm Control Panels with a mappable relay control module. * � ,tIrk <br /> sz. _rn <br /> Features 1.1lt�zr csr n ' �, j <br /> • Provides eight Form-C relays with 5-amp contacts. • r <br /> • The relays can be employed to track a variety of devices and • r <br /> O! 'Lint; <br /> panel points, in a grouped fashion. •. _ ie 1 <br /> • Removable terminal blocks for ease of installation and ser- o 7,2. h.* . <br /> vice. r" <br /> • DIP switch selectable memory mapping of relays. ;'`O it )�[�[ '* . <br /> NOTE: The ACM-8R can also be used with legacy panels. Please _ �` <br /> refer to the ACM-8R manual(document 15382). <br /> IriQ use + : ; 6 er <br /> Mounting a 1 ._ !> o <br /> The ACM-8R module will mount to CHS-4 chassis, a CHS-4L ° <br /> low-profile chassis(assumes one of four positions on the chas E <br /> sis), or CHS-4MB; or for remote applications, to an ABS-8RB [0' ' . ._ <br /> Annunciator Surface-mount backbox with blank faceplate. �- <br /> . vnSsr_ <br /> Limits <br /> The ACM-8R is a member of the Notifier ACS class of annuncia- ACM-8R Relay Module <br /> tors. Up to 32 annunciators (not including expander modules) <br /> may be installed on an EIA-485 circuit. <br /> Wire Runs NFS2-3030, NFS2-640 AND NFS-320 CIRCUITS <br /> Communication between the control panel and the ACM-8R is The ACM-8R can track a variety of input, output, panel func- <br /> accomplished over a two-wire EIA-485 serial interface. This tions, and addressable devices in a grouped fashion on the <br /> communication, to include the wiring, is supervised by the fire AFP-300/400. The ACM-8R can track: <br /> alarm control panel. Power for the annunciators is provided via • CPU status <br /> a separate power loop from the control panel, which is inher- • Soft zones <br /> ently supervised (loss of power also results in a communication <br /> failure at the control panel). • Special hazard zones. <br /> • Addressable circuits <br /> Relay Mapping • Power supply NACs. <br /> The ACM-8R's relays can follow the status of initiating and indi- • Selectable points (NFS2-640 and NFS-320) when tracking <br /> cating circuits, control relays, and several system control func- "special"annunciator points. <br /> tions. <br /> Agency Listings and Approvals <br /> These listings and approvals apply to the modules specified in <br /> this document. In some cases,certain modules or applications <br /> may not be listed by certain approval agencies, or listing may <br /> be in process. Consult factory for latest listing status. <br /> • UL Listed: S635 <br /> • ULC Listed:CS635 Vol. I <br /> • MEA Listed:104-93-E Vol.6; 17-96-E; 291-91-E Vol.3 <br /> • FM Approved: <br /> • CSFM:7120-0028:156 <br /> • FDNY: #6039 <br /> Relay Terminal Assignments <br /> The ACM-8R provices eight relays with Form"C"contacts rated <br /> for 5 A. The terminal assignments are illustrated below. <br /> DN-3558:a1•01/19/10—Page 1 of 2 <br />