5901 23RD DR W 2023 ZAP ENERGY Plans 2025-03-19
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
Plans
>
5901 23RD DR W 2023 ZAP ENERGY Plans 2025-03-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2025 8:58:43 AM
Creation date
3/19/2025 8:58:32 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Permit
K2303-006
Year
2023
Notes
CLEAN AGENT FIRE SUPPRESSION FOR CAPACITOR STORAGE ROOM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUPAESSION SYSTEMS INC. <br /> SPECIAL HAZARDS FIRE PROTECTION <br /> n ROTH STREET EAST,SURE 3 <br /> 24'-0' I EWE WA 0S.241793-(SS.azau00 FAX 0Ss)azeaa00 <br /> 1 <br /> NICET STAMPS <br /> 3 3 <br /> n .1 - <br /> �020 e021 MC.4 <br /> 024-SUB-FLOOR 025-SUB-FLOOR N <br /> MANUFACTURER LOGO'S <br /> NAC 2 EOL o ^ CONNECT TO %�Kidde <br /> Hi o o BUILDING Fire Systems <br /> o o NAC 2 FACP)A yxa BY SSI <br /> E.O O B'-0" <br /> 020UCOM802EOL ��� _ S-0» <br /> NAC2 A 2fr <br /> A __ 0 \•� Q O T 'FIRE PROTECTION ENGINEERS STAMP <br /> ___ \ U- <br /> Id.005 0 - 1 i <br /> O n <br /> Oh 006: ci) in <br /> REL 1 E3i�P 1 I I� <br /> CAPACITOR STORAGE <br /> ;©` CLEAN AGENT PIPING PLAN <br /> C.H. 9'-9" /SUB-FLOOR 1'-4" COMPUANCE DATE <br /> SUBMITTALS <br /> LOCATE MANUAL / SCALE:1/4"=1'-0" 100%SUBMITTAL 02/08/23 <br /> RELEASE <br /> STATION PER <br /> CUSTOMER <br /> INSTRUCTION REV DESCRIPTION DATE <br /> 004 CREVIEW <br /> OMMENTS C2/17/23 <br /> 3/4°90°(TYP.2) <br /> .L <br /> EXI57NS CONTRGL ROOM ---3/4"X 5-6" ' <br /> IAIO / - - <br /> - - 3/4"X I4'-0" 7 \� A <br /> \ / SEE DETAIL"A°THIS SHEET M <br /> O <br /> 4 3/4"X 2-0"-i 3/4'DISCHARGE HOSE(TYP.5) / Q 2 <br /> 0) <br /> --3/4'X 1!2"REDUCER 2"PRE-BUILT MANIFOLD _I LLI j <br /> 3/4'X 1'-0"-- 0 <br /> WITH 3/4"CHECK VALVES <br /> El-N1 r CYLINDER VALVE AND PRE-INSTALLED c <br /> (38-40 7600-1 25] O DISCHARGE HOSE SEE G } <br /> / ACTUATION DETAIL 0 CC <br /> p Z ILI <br /> 1/2"X 10'-8" CC 0 <br /> CAPACITOR STORAGE MANIFOLD END CAP O 6 <br /> ''p`CLEAN AGENT DETECTION AND <br /> W <br /> CONTROLS PLAN (38-407500.O44 ' r <br /> I- CC <br /> SCALE:1/4"=1'-0" Q <br /> U w <br /> W UJ <br /> 0CC w <br /> cc LL" <br /> W I- p <br /> VOLUME CALCULATION NOTES: CLEAN AGENT AREA VOLUME CALCULATIONS g w w 0 <br /> 1. FORMULA FOR CALCULATIONS: <br /> 1.1. AREA x DEPTH=VOLUME MINIMUM ADJUSTED o 0 N <br /> 1.2. MINIMUM AMOUNT OF AGENT REQUIRED X ELEVATION CORRECTION= AGENT ELEVATION MINIMUM AGENT <br /> ADJUSTED MINIMUM AGENT REQUIRED 3/4.90.NPT OBI-- 3/4"NPT TO SYSTEM PIPE ROOM DESCRIPTION AREA DEPTH VOLUME CONCENTRATION AGENT AGENT CORRECTION AGENT SUPPLIED CYLINDER w <br /> AND NOZZLES (SQUARE FEET) (FEET) (CUBIC FEET) (%BY VOLUME) FACTOR REQUIRES FACTOR REQUIRED (POUNDS) SUPPUED Ill C)) <br /> 2. NON-PERMEABLE VOLUME OF 4SCF APPUEO. REDUCER 3/4"X 1/2"NPT (POUNDS) a In <br /> 3. FOR ADDITIONAL INFORMATION SEE THE CLEAN AGENT FLOW CALCULATIONS TEE 3/4"NPT [ IIIIR� (POUNDS) <br /> INCLUDED IN THE SUBMITTAL PACKAGE. M. 1/2"90°NPT <br /> ._. CAPACITOR ROOM 480.0 9'-9" 4680 46.90 0.0461 214.7 - 214.7 238.8 - <br /> 4. AGENT DESIGN CONCENTRATION IS FROM NFPA 2001 AND MANUFACTURE UNION 1/2"NPT DESIGNED BY.NMB SCALE: <br /> RECOMMENDATIONS. UNION 314"NPT ;=; CAPACITOR ROOM SUB-FLOOR 480.0 1'-4" 640 46.90 0.0461 29.4 - 29.4 32.7 - DRAWN BY: NMB NOT <br /> 6 II-DISCHARGE PRESSURECHECKED BY:ZST u" <br /> REDUCE 2"X 3/4"NPT--- TOTAL - - - - - 244.1 - 244.1 271.5 5-80L JOB NUMBER:2306 1 IER <br /> NOTED <br /> ISOMETRIC PIPING NOTES: SWITCH 1/2°NPT o HERwuE <br /> 5. PIPE LENGTH'S DO NOT REPRESENT CUT LENGTH'S. PRESSURE RELIEF VENT (PRV) / EQUIVALENT LEAKAGE AREA (ELA) CALCULATIONS <br /> 6. ALL LENGTHS SHALL BE FIELD VERIFIED. SHEET TITLE: <br /> IN FROM 2"MANIFOLD m,ml FIRE PROTECTION DRAWINGS <br /> 7. ALL PIPING 1/2"TO 1 1!2"SHALL BE THREADED.MINIMUM AND MAXIMUM <br /> PRESSURE RATINGS SHALL MEET FSSA PIPE DESIGN GUIDE FOR USE WITH 2»90° CALCULATIONS PERFORMED BY KIDDE KFS HYDRAULIC FLOW SOFTWARE v4.00 ESTIMATED FREE VENT AREA <br /> FLOOR PLANS <br /> SPECIAL HAZARD FIRE SUPPRESSION SYSTEMS. L AGENT <br /> B. ALL PIPING 2"TO 6"SHALL BE GROOVED.MINIMUM AND MAXIMUM PRESSURE ADAPTER 2",BSP TO NPT AGENT SUPPLIED DISCHARGE TIME VOLUME MAXIMUM PRESSURE REQUIRED <br /> ROOM DESCRIPTION (POUNDS) CONCENTRATION (SECONDS) (CUBIC FEET) (PSF) (SQUARE FEET) AND ISOMETRICS <br /> RATINGS SHALL MEET FSSA PIPE DESIGN GUIDE FOR USE WITH SPECIAL DETAIL"A" (%BY VOLUME) <br /> HAZARD FIRE SUPPRESSION SYSTEMS. • <br /> 9. ANY DEVIATIONS IN PIPE LENGTH OR SIZE SHALL BE APPROVED BY CAPACITOR ROOM& 271.5 50.50 113.5 5320 5'0 0.90 SHEET NUMBER: <br /> • SUPPRESSION SYSTEMS INC.PRIOR TO BEGINNING INSTALLATION. SUB-FLOOR - - FP-04 of 07 <br />