Laserfiche WebLink
SUPRESSION SYSTEMS INC. <br /> * SPECIAL MEMOS RiEPROTWTgN <br /> SO77 20TH STREET EAST,SUITE B <br /> FIE WA SWIE41790 <br /> .(453)920.100 FM REMENESSO <br /> AO RELAY MODULE <br /> NICET STAMPS <br /> ff�:, <br /> .,,,,, _ I <br /> Al -,ZrItilon•LEva. <br /> n ii4L— - <br /> MONITOR MODULE <br /> • <br /> MANUFACTURER LOGOS <br /> �( l fKidde <br /> �1 8 ;� Fire Systems <br /> DETECTOR BASE <br /> EtC:2: 11112 \'', .); '',..•>'4,6_-)1 a <br /> ® 1 T 1 .je 1 1• '". ,.„9. ® 0 I b 0P in <br /> el <br /> ®C J ® FIRE PROTECTION ENGINEERS STAMP <br /> li v:m <br /> PROGRAMMABLE <br /> RELAYST.E.T.,C;a <br /> p Ca9Ns p ara a Tau E U g2ENCE❑ <br /> ,-; <br /> " ? O O <br /> O � O ❑ ° `O <br /> TROUBLES j' fladde ElO CD O O <br /> RELAY I:" <br /> c 0 Fire Systems O O 10 0 0 <br /> .\ <br /> O COMPLIANCE DATE <br /> SUBMITTALS <br /> • LC-STYLE SWITCH(S2) <br /> 100%SUBMITTAL 02/08/23 <br /> O R._LL (� <br /> REVIEW <br /> i <br /> 2 2 ; E I REV DESCRIPTION DATE <br /> q_ l„ <br /> = AC SUPPLY SELECT SWITCH(S4) ` OTTO 10kEOLA <br /> COMMENTS 02/17/23 <br /> TB3 p Q <br /> . TB2 AUXILIARY OUTPUTS F <br /> um REGULATED 24 VDC, Q <br /> a•• CURRENT:1.0(MAX)EACH OUTPUT <br /> LI <br /> am POLARIZED NOTIFICATION Q <br /> * 120 VAC,50/60 Hz,3.2 A WHITE \ A/B APPLIANCE(TYPICAL) <br /> or BLACK : „ '� TB12 T811 \ TB2 TB7 TB6 <br /> 240 VAC,50/60 Hz,1.6 A GREEN, i 1 ''"-I I .'I i '. 1 1 '-j 01 <br /> ®TB13 H oopn G uuuu u©au o G oon HoETETo $ O <br /> 5 N <br /> T"fBUFSNbda+i = u9 w . o".a"z Lco <br /> co <br /> SOLENOID BLK RED - -o V <br /> / • <br /> 0 C w <br /> cc <br /> 10K IN-UNE RELEASING DEVICE(LOCATE L 00 0 <br /> AS CLOSE AS POSSIBLE TO SOLENOID) <br /> + - + POLARIZED NOTIFICATION o <br /> APPUANCE(TYPICAL) O � O <br /> H - w 1= <br /> r 1 W <br /> cc <br /> W I— cc <br /> o <br /> POWER SUPPLY: RELAYS(POWER OR NON-POWER LIMITED BUT NOT BOTH): SIGNAUNG UNE CIRCUIT(SLC): NOTIFICATION APPUANCE CIRCUITS(NAC)AND RELEASINGZ <br /> *"5 AMP MAXIMUM AU.EXTERNAL DEVICES** TB#4,TB#8,TB#9-PROGRAMMABLE RELAY SPDT FORM C TB#1 SIGNALING UNE CIRCUIT WIRING REQUIREMENTS CIRCUITS: $ Z III V cc <br /> NOTE:EXTERNAL DEVICES INCLUDE ALL NOTIFICATION APPLIANCES,CONTACT POWER UNITED AND SUPERVISED TB#6 AND TB#14 NAC CIRCUITS <br /> RELEASING SOLENOIDS,SLC INITIATING AND CONTROL DEVICES RATED FOR 1.0 AMPS @ 30 VDC(RESTRICTIVE) UP TO 255 ADDRESSABLE DEVICES POWER UNITED AND SUPERVISED z a- Q N <br /> AND ALL DEVICES POWERED FROM THE PANEL POWER SUPPLY. RATED FOR 0.5 AMPS @ 30 VDC(INDUCTIVE) CLASS"B"STYLE 4 NOT'T TAPPABLE M' Q El <br /> TB#13-AC/DC POWER SUPPLY UNIT RATED FOR 0.5 AMPS @ 120 VDC(INDUCTIVE) (CLASS'A'CONDUIT SEPARATION SHALL BE MAINTAINED AT A REGULATED 24VDC,1.5 AMPS MAX PER CIRCUIT a N a) <br /> 5.4 A @ 27VDC TB#10-TROUBLE RELAY SPDT FORM C CONTACT MINIMUM CLASS"B',STYLE"Y'/CLASS"A',STYLE'Z" <br /> 120 OR 240 VAC RATED FOR 1.0 AMPS @ 30 VDC(RESTRICTIVE) OF 1 FOOT VERTICALLY AND 4 FEET HORIZONTALLY.NFPA 72 MAXIMUM#SYNCHRONIZED DEVICES PER CIRCUIT IS 25 <br /> 50/60 Hz LINE VOLTAGE RATED FOR 0.5 AMPS @ 30 VDC(INDUCTIVE) CHAPTER 6 TB#11 AND TB#12 RELEASING CIRCUITS DESIGNED BY:NMB SCALE: <br /> NON-POWER LIMITED RATED FOR 0.5 AMPS @ 120 VDC(INDUCTIVE) CLASS"A'STYLE 6 SERIES WIRED INITIATOR ASSEMBUES DRAWN BY: NMB NOTTO <br /> SCALE <br /> TB#3-BATTERY CONNECTION CLASS"A'STYLE 7 USING ISOLATOR DEVICES SINGLE CONTROL HEAD OR SOLENOID VALVE CHECKED BY:ZST UNLE&S <br /> SUPERVISED AUXIUARY POWER: 350MA MAX/28VDC MAX/40 OHMS MAX/20Pf PER FOOT TWO SERIES-SUPERVISED,PARALLEL-ACTUATED JOB NUMBER:2306 OTHERWISE <br /> 24 VDC NOMINAL TB#2-RESETABLE 24VDC POWER OUTPUT TWISTED,UNSHIELDED,LOW-CAPACITANCE, CONTROL HEADS OR SOLENOID VALVES <br /> MAX.BATTERY SIZE 70 AH POWER LIMITED AND SUPERVISED ADDRESSABLE-FIRE ALARM WIRE MAX RELEASE CURRENT 2,4 AMPS PER CIRCUIT SHEET TITLE <br /> NON-POWER LIMITED-DEDICATED CIRCUIT 1 AMP MAXIMUM EACH CIRCUIT TB#6 AND TB#7 COMBINATION CIRCUITS FIRE PROTECTION DRAWINGS <br /> **5 AMP MAXIMUM ALL EXTERNAL DEVICES** PROGRAMMED AS NAC CIRCUITS FUNCTION THE SAME AS <br /> NOTE:EXTERNAL DEVICES INCUDE ALL NOTIFICATION APPUANCES, ABOVE ELECTRICAL DETAILS <br /> - RELEASING SOLENOIDS,SLC INITIATING AND CONTROL PROGRAMMED AS RELEASE CIRCUITS CAN SUPPORT ONE MULTI-LINE WIRING DIAGRAM <br /> DEVICES AND ALL DEVICES POWERED FROM THE 24 Vdc POWER CONTROL HEAD OR ONE PRE-ACTION SOLENOID <br /> SUPPLY. <br /> ARIES-SLX TYPICAL WIRING DIAGRAM SHEET NUMBER: <br /> FP-05 of 07 <br />