Laserfiche WebLink
• • <br /> Response#4: <br /> Carport layout has been adjusted to be 5ft away from property lines. <br /> Accessibility <br /> 5. Correction#8: <br /> The carports are required to include accessible spaces. The number of accessible spaces should <br /> be based on IBC Table 1106.1. Spaces should be van-accessible per Section 1106.5. The spaces <br /> should be located on the shortest route to the buildings served per Section 1106.6. Spaces should <br /> comply with ICC A117.1-09 Section 502 including signs per Section 502.7. See IBC Sections <br /> 1102.1 and 1103.2.4(2). <br /> Response#8: <br /> Carport layout adjusted to include ADA parking stalls,along with an added ADA van stall. <br /> Structural <br /> General <br /> 1. Correction#1: <br /> Footing Detail 01/S2.0 should be provided with top reinforcement per ACI 318-14 Section <br /> 10.7.6.1.6. Alternatively,an analysis per Section 17.2.3.5.3 should be performed to substantiate <br /> that splitting of the foundation does not occur from flexural restraint of the embedded posts. See <br /> IBC Sections 1604.1 and 1604.4. <br /> Response#1: <br /> See Structural response letter <br /> 2. Correction#2: <br /> The design of the canopies does not appear to include unbalanced loading of the roof structure in <br /> the transverse direction,including but not limited to the WF-beam, HSS-column,and foundation <br /> designs. Additional calculations substantiating both internal stresses and global stability(e.g., <br /> bearing pressures, rotational stability per IBC Section 1807.3,etc.)should be submitted for review. <br /> Snow loads should be combined with other loads as required(e.g.,wind uplift on the opposite <br /> cantilever,etc.)to determine the worst-case forces in the structures. See IBC Section 1608.1 and <br /> ASCE 7-16 Section 7.5. <br /> Response#1: <br /> See structural response letter. <br /> Feel free to contact me if you have any questions. <br /> Thank you for your assistance. <br /> Regards, <br /> Cassandra Cheatham,Project Designer <br /> 206-682-5211 <br /> cassandra@kilburnarchitects.com <br /> Plan Check No.: B2212-057, First Building Review—Revision Response Letter <br /> z12 <br />