• 411 <br /> Ms. Cassandra Cheatham <br /> Kilburn Architects, LLC <br /> Plan Check Number: B2212-057, Second Building Review <br /> May 24, 2023 <br /> General <br /> 1. The structural drawings have been printed at 1/2-size on full-size drawing sheets. The structural <br /> drawings should be submitted at full size as was provided in the drawings originally submitted <br /> with the permit application. <br /> Architectural <br /> General: <br /> 1. References to the 2018 IEBC were removed in response to this comment. The 2018 IBC should <br /> be specified as the reference code for this project. <br /> 2. This comment has not been addressed as stated by the response. The Occupancy Classification <br /> on Sheet A-0.1 should be specified as"U"in the"Project Data"; a"R-2"classification is still <br /> stated. See IBC Sections 302.1 and 312.1. <br /> 3. This comment has not been addressed as stated by the response. The Construction Type on <br /> Sheet A-0.1 should be specified as"VB" in the"Project Data"; a "VA"type is still stated. <br /> Alternatively, fire-rated construction for the roof, beams, and columns is required per IBC Table <br /> 601. See IBC Sections 602.1 and 602.5. <br /> Fire Protection: <br /> 4. The design has been revised in response to the original comment to located Carports 2, 3, and <br /> 4 at least 5 feet from the property lines. However, Carport 1 is located less than 20 feet from <br /> the existing"R-2"building with a "V-A"construction. An imaginary property line must be <br /> established between the structures and the respective fire separation distances (FSD) specified. <br /> It is noted that the existing building may not have sufficient construction for the proposed FSD <br /> without modifications. Alternatively, Carport 1 should be redesigned to provide the minimum <br /> FSD without modifications. See IBC Table 602. <br /> Structural <br /> 1. This comment has not been addressed. Calculation pages 22 and 23 referenced in the <br /> response do not provide a splitting analysis of the foundation to verify that confinement will be <br /> maintained in the footings to preclude failure of the structure. Footing Detail 01/52.0 should be <br /> provided with top reinforcement per ACI 318-14 Section 10.7.6.1.6. Alternatively, an analysis <br /> per Section 17.2.3.5.3 should be performed to substantiate that splitting of the foundation does <br /> not occur from flexural restraint of the embedded posts. See IBC Sections 1604.1 and 1604.4. <br /> O3200 Cedar Street 0 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/ its <br /> Page 2 of 3 <br />