• • <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Wednesday,August 2, 2023 2:48 PM <br /> To: H.Todd Kilburn <br /> Subject: City of Everett Permit Services: 10111 9th Avenue W(B2212-057) -Third Building <br /> Review <br /> Hello,Todd. <br /> We have received revised documents for this project. However,some comments do not appear to be adequately <br /> addressed. In addition,the Planning reviewer has issued comments that may impact the overall design of the <br /> project. The previously submitted comments should be reviewed again and additional revisions performed as needed in <br /> addition to changes required by the Planning comments. <br /> In addition to the review comments,the revised drawings only include excerpts. The City of Everett does not collate <br /> drawing sets on the applicant's behalf. Two full sets of revised construction drawings are required to be submitted. <br /> Supplemental Comments are provided for some of the comments issued in the Second Review dated May 24, <br /> 2023. These are in addition to and itemized with the previous comments. <br /> Architectural <br /> 2.The "Project Data" section of the drawings should reflect the proposed work, not the condition of other buildings on <br /> the same lot. Information should be specified for other buildings that impact the proposed project, such as in the <br /> "Project Description" statement or Site Plan 1 A-0.1. Entries such as but not limited to "Buildings", "Occupancy",j p / gand <br /> "Construction Type" should be used for the proposed project, not other buildings on the site as they are not the current <br /> scope of work. <br /> 5.The buildings do not appear to have sufficient separation to comply with the FSD for each structure without fire-rated <br /> construction. The existing building(VA) requires a minimum distance of 30 feet and the nearest carport(VB) requires a <br /> minimum distance of 10 feet,for a total separation of 10 feet. Alternatively, provide supplemental documentation <br /> substantiating that the structures comply with the requirements for reduced FSD, including but not limited to the <br /> opening limits per IBC Table 705.8. <br /> Please contact us if you have questions. Thank you. <br /> Drew Martin, P.E., S.E. <br /> LIAssociate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M/W/T:8 am - 12 pm & 1 pm—3 pm;Tu: 1:OOpm-3:OOpm <br /> everettwa.gov/permits I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> 1 <br />