My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10111 9TH AVE W EMERALD COURT APARTMENTS 2025-04-18
>
Address Records
>
9TH AVE W
>
10111
>
EMERALD COURT APARTMENTS
>
10111 9TH AVE W EMERALD COURT APARTMENTS 2025-04-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2025 2:45:44 PM
Creation date
3/20/2025 10:56:22 AM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE W
Street Number
10111
Tenant Name
EMERALD COURT APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> kw <br /> • • Architecture <br /> Interior Design <br /> 135 Lake Street South <br /> Suite 250 <br /> Kirkland,WA 98033 <br /> KILBURN 206-682-5211 Tel <br /> ARCHITECTS LLC 206-682-1403 Fax <br /> rE[VE <br /> 11 September 2023 <br /> City of Everett—Permit Services SEP 1 1 2023 <br /> Attn: Drew Martin <br /> 3200 Cedar Street CITY OF EVERETT <br /> Everett, WA 98201 Permit Services <br /> Re: Correction Notice#3—BUILDING REVIEW <br /> Project#B2212-057—10111 9th Avenue W. <br /> Mr. Martin, <br /> The following is our responses to your correction notice (e-mail supplemental) #3 dated August 2, <br /> 2023: <br /> General <br /> 1. Correction#1: <br /> The structural drawings have been printed at 1/2-size on full-size drawing sheets. The structural <br /> drawings should be submitted at full size as was provided in the drawings originally submitted with <br /> the permit application. <br /> Response#1: <br /> Sheets provided are at full size set. Both architectural and structural. <br /> Architectural <br /> General: <br /> 1. Correction#1: <br /> References to the 2018 IEBC were removed in response to this comment. The 2018 IBC should be <br /> specified as the reference code for this project. <br /> Response#1: <br /> Under Building Code (to left side of sheet) it states it shall comply with 2018 IBC. <br /> 2. Corrrection#2: <br /> This comment has not been addressed as stated by the response. The Occupancy Classification <br /> on Sheet A-0.1 should be specified as"U" in the"Project Data"; a"R-2"classification is still stated. <br /> See IBC Sections 302.1 and 312.1. <br /> Response#2: <br /> See sheet A-0.1 Project Data section updated. <br /> I/2_ <br />
The URL can be used to link to this page
Your browser does not support the video tag.