Laserfiche WebLink
3 of 8 <br /> LONGITUDE <br /> ONE TWENTYO <br /> ENGINEERING&DESIGN <br /> 2. Existing crack located between piles#2 &#3 (directly under crawlspace vent opening): <br /> • Please provide a minimum 6'-0" C6x8.2 channel to span between piles#243 (centered on <br /> crack) and be anchored to existing concrete footing/ 5/8" Titen HD screw anchors with <br /> minimum 4"embed into the concrete. Anchors shall be installed @ 12"o.c. with 6"or less <br /> from each end of steel member. (Channel may be installed at interior or exterior of <br /> foundation wall). In addition, please provide carbon fiber stitching with high strength <br /> anchoring epoxy to be applied perpendicular to the cracks @ 8"o.c.for full length of crack. <br /> Please ensure minimum 12" development past crack is achieved for each strip. <br /> L <br /> yp <br /> ?tea <br /> A <br /> �•T�- <br /> 909502 <br />