Laserfiche WebLink
1 F V H I E W E'S MEMBER REPORT PASSED <br /> Roof Deck, DB-1 <br /> 1 piece(s) 5 1/8"x 16 1/2" 24F-V4 DF Glulam <br /> Overall Lerg±:12' <br /> I! 0 <br /> r <br /> I <br /> 'I l 4. <br /> CI El <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 7578 @ 2" 11211(3.50") Passed(68%) -- 1.0 D+0.75 L+0.75 S(All Spans) Member Type:Drop Beam <br /> Shear(Ibs) 5694 @ 1'8" 14939 Passed(38%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Building Code:IBC 2015 <br /> Pos Moment(Ft-Ibs) 29351 @ 8'10 5/8" 45837 Passed(64%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.373 @ 9'3/8" 0.589 Passed(L/569) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> Total Load Defl.(in) 0.506©8'11 1/2" 0.883 Passed(L/419) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> • Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L=17'8". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Snow Factored Accessories <br /> 1-Stud wall-DF 3.50" 3.50" 2.37" 2547 4543 2164 7578 Blocking <br /> 2-Stud wall-DF 3.50" 3.50" 2.20" 1653 5029 2142 7031 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 18'o/c <br /> Bottom Edge(Lu) 18'o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Dead Floor Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 18' N/A 20.5 -- -- <br /> 1-Uniform(PSF) 5'6"to 18'(Top) 9'6" 15.0 60.0 25.0 Full Deck <br /> 2-Uniform(PSF) 0 to 5'6"(Top) 3'3" 15.0 60.0 25.0 Partial Deck <br /> 3-Uniform(PSF) 0 to 5'6"(Top) 6'3" 15.0 40.0 - Partial House <br /> 4-Uniform(PLF) 0 to 5'6"(Top) N/A 100.0 - - Wall Above <br /> i 5-Uniform(PLF) 0 to 5'6"(Top) N/A 130.0 - 162.0 Roof <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be In accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator Job Notes 1/25/2023 11:11:05 PM UTC <br /> Andreas Quinn <br /> Bykonen Carter Quinn A ForteWEB v3.5,Engine:V8.2.3.63,Data:V8.1.3.6 <br /> (206)264-7784 <br /> avq@bcq-se.com Weyerhaeuser File Name:Greenleaf Garage <br /> Panes 6 /9 I Iq <br />