620 LAUREL DR 2025-04-16
>
Address Records
>
LAUREL DR
>
620
>
620 LAUREL DR 2025-04-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2025 9:43:08 AM
Creation date
3/20/2025 11:51:30 AM
Metadata
Fields
Template:
Address Document
Street Name
LAUREL DR
Street Number
620
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a FUK I t W hid MEMBER REPORT PASSED <br /> Roof Deck, DB-2 <br /> 1 piece(s) 5 1/8"x 16 1/2" 24F-V4 DF Glulam <br /> Overall Lergth:13' <br /> - r <br /> 0 <br /> I <br /> 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 9154 @ 2" 11211(3.50") Passed(82%) -- 1.0 D+0.75 L+0.75 S(All Spans) Member Type:Drop Beam <br /> Shear(Ibs) 6854 @ 1'8" 14939 Passed(46%) 1.00 1.0 D+1.0 L(All Spans) Building Use:Residential <br /> Building Code:IBC 2015 <br /> Pos Moment(Ft-Ibs) 35346 @ 8'10 5/8" 45837 Passed(77%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.458 @ 9'3/16" 0.589 Passed(L/463) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> Total Load Defl.(in) 0.611 @ 8'11 1/2" 0.883 Passed(L/347) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> • Deflection criteria:LL(L/360)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> •Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L=17'8". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Snow Factored Accessories <br /> 1-Stud wall-DF 3.50" 3.50" 2.86" 2817 5717 2732 9154 Blocking <br /> 2-Stud wall-DF 3.50" 3.50" 2.65" 1923 6125 2612 8476 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 18'o/c <br /> Bottom Edge(Lu) 18'o/c <br /> •Maximum allowable bracing Intervals based on applied load. <br /> Dead Floor Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 18' N/A 20.5 -- -- <br /> 1-Uniform(PSF) 5'6"to 18'(Top) 11'6" 15.0 60.0 25.0 Full Deck <br /> 2-Uniform(PSF) 0 to 5'6"(Top) 6'3" 15.0 60.0 25.0 Partial Deck <br /> 3-Uniform(PSF) 0 to 5'6"(Top) 5'3" 15.0 40.0 - Partial House <br /> 4-Uniform(PLF) 0 to 5'6"(Top) N/A 100.0 - - Wall Above <br /> 5-Uniform(PLF) 0 to 5'6"(Top) N/A 130.0 - 162.0 Roof <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator Job Notes 1/25/2023 11:11:05 PM UTC <br /> Andreas Quinn <br /> Bykonen Carter Quinn ForteWEB v3.5,Engine:V8.2.3.63,Data:V8.1.3.6 <br /> avq@bcq-se.com(206) 84 File Name: Greenleaf Garage � <br /> Weyerhaeuser g p ��� <br /> Panesf, /QI� <br />
The URL can be used to link to this page
Your browser does not support the video tag.