Laserfiche WebLink
HUNTSMAN <br /> BUILDING SOLUTIONS <br /> HEA1 LOK° HFO PRO <br /> 000 TECHNICAL DATA SHEE i <br /> Heatloe HFO Pro is a two component,closed cell,spray applied,rigid polyurethane foam system.This product uses recycled plastic materials,rapidly renewable soy oils, <br /> and the blowing agent has zero ozone depleting potential.Heatlok HFO Pro complies with the intent of the International Code Council's residential and commercial building <br /> codes and is commonly used as a thermal insulation,air barrier,vapor retarder and water resistive barrier in above grade,below grade,interior and exterior applications. <br /> PHYSICAL ••• <br /> ASTM D 1622 Core Density 2.0—2.4 Ib/ft3 32.0—38.4 kg/m3 <br /> ASTM C 518 Aged Thermal Resistance 1"=7.4 ft2h2F/BTU 3.5"=23 ft2h°F/BTU <br /> 1"=1.3Km/W 3.5"=4.04Km/W <br /> ASTM E 283 Air Leakage @ 75 Pa @ 1" <0.02 L/sm2 <br /> ASTM E 2178 Air Permeance @ 75 Pa @ 1 <0.02 L/sm2 <br /> Water Vapor Permeance 0.91 perms 52.5 ng/Pa•s•m2 <br /> ASTM E 96 Class II vapor retarder per IBC Section 202 @ 1" <br /> Class II vapor retarder @<1 perm 1" 25.4mm <br /> ASTM D 2842 Water Absorption(volume) 0.3% <br /> ASTM D 1621 Compressive Strength 31 psi 214 kPa <br /> ASTM D 1623 Tensile Strength 44 psi 303 kPa <br /> ASTM D 2126 Dimensional Stability @ 158°F(70°C)97%R.H.(168 hours) -3.7(%volume change) <br /> VOC Emissions UL Environment(Greenguard Gold) Meets Criteria <br /> ASTM C 1338 Fungi Resistance No fungal growth <br /> ASTM D 2856 Closed Cell Content 98% <br /> ASTM C 1029 Standard specification for spray applied rigid cellular Type II Compliant <br /> polyurethane thermal insulation <br /> FIRE TEST RESULTS <br /> Surface Burning Characteristics,4"thick Class I <br /> ASTM E 84 Flame Spread Index 12 <br /> Smoke Developed 350—400 <br /> Ignition Barrier—Compliant with 2012,2015,2018&2021 IBC and IRC,and ICC-ES <br /> AC 377 Appendix X AC-377 Appendix X,for use in attics and crawl spaces without a prescriptive ignition barrier or Pass <br /> intumescent coating. <br /> Compliant with 2012,2015,2018&2021 IBC with brick,metal or aluminum cladding for exterior <br /> NFPA 285 walls of Type I,II,III and IV buildings of any height.See UES 565 Tables for specific assembly requirements. Pass <br /> Contact the Huntsman Building Solutions Engineering Department for assistance with alternate assemblies. <br /> Thermal Barrier—Compliant with the 2012,2015,2018&2021 IBC and IRC,as an interior finish without <br /> NFPA 286 a 15 minute thermal barrier when coated with DC-315 at 18 mils wet film thickness,12 mils dry film Pass <br /> thickness,or BlazelokTm TBX at 18 mils wet film thickness,12 mils dry film thickness. <br /> CONTENTRECYCLED&RENEWABLE <br /> Recyclable Content 19% <br /> Renewable Content 6% <br /> PROFILEREACTIVITY <br /> Cream Time Gel Time Tack Free Time End of Rise <br /> 0 —1 seconds 2 seconds 3—4 seconds 3—4 seconds <br /> Page 1 of 2 <br />