Laserfiche WebLink
PROPERTY A-PMDI ISOCYANATE HEATLOK HFO PRO RESIN <br /> Color Brown Blue <br /> Viscosity @ 77°F(25°C) 180—220 cps 500—800 cps <br /> Specific Gravity 1.24 1.17—1.21 <br /> Shelf Life of unopened drum properly stored 12 months 6 months <br /> Storage Temperature 50—100°F(10—38-C) 59—77°F(15—25-C) <br /> Mixing Ratio(volume) 1:1 1:1 <br /> 'See SDS for more information. <br /> RECOMMENDED PROCESSING CONDITIONS' <br /> Initial Primary Heater Setpoint Temperature 105—115°F 41 —46°C <br /> Initial Hose Heat Setpoint Temperature 105—115°F 41 —46°C <br /> Initial Processing Setpoint Pressure 1200—1400 psi 8274—9653 kPa <br /> Substrate&Ambient Temperature Summer>50°F Summer>10°C <br /> Winter>15°F Winter>-9°C <br /> Moisture Content of Substrate s19% s19% <br /> Moisture Content of Concrete Concrete must be cured,dry and free of dust and form release agents. <br /> `Foam application temperatures and pressures can vary widely depending on temperature,humidity,elevation,substrate,equipment and other factors.While <br /> processing,the applicator must continuously observe the characteristics of the sprayed foam and adjust processing temperatures and pressures to maintain proper <br /> cell structure,adhesion,cohesion and general foam quality.It is the sole responsibility of the applicator to process and apply Heatlok HFO Pro within specification. <br /> General Requirements:Equipment must be capable of delivering the proper ratio(1:1 by volume)of polymeric isocyanate(PMDI)and polyol blend at adequate <br /> temperatures and spray pressures.Substrate must be at least 5 degrees above dew point,with best processing results when ambient humidity is below 80%. <br /> Substrate must also be free of moisture(dew or frost),grease,oil,solvents and other materials that would adversely affect adhesion of the polyurethane foam. <br /> Applicators should limit the application of this product to no more than a thickness of 2"(5Omm)per pass(after expansion)to avoid fire hazards(including sponta- <br /> neous combustion)resulting from excessive heat generation.A second 2"(5Omm)layer may be applied immediately after the first one has fully risen.Alternatively,a <br /> single pass of up to 3"(76mm)may be applied.In either case,if subsequent passes are needed,applicators should wait until the core temperature of the foam has <br /> dropped below 100°F to allow any reaction heat to dissipate from the prior applications before attempting to reapply the product. <br /> RECOMMENDED <br /> Maximum Pass 3" 76mm <br /> Dual Pass(x"+x") 2"+2" 5Omm+5Omm <br /> Heatlok HFO Pro must be separated from the interior of the building by an approved thermal barrier or an approved finish material equivalent to a thermal barrier in <br /> accordance with applicable codes.Heatlok HFO Pro must be sprayed at a minimum thickness of 1"per pass.This product must not be used when the continuous <br /> service temperature of the substrate or foam is below-60oF(-51°C)or above 180°F(82°C).Heatlok HFO Pro should not be used to cover flexible ductwork. <br /> Disclaimer:The information herein is to assist customers in determining whether our products are suitable for their applications.We request that customers inspect <br /> and test our products before use and satisfy themselves as to contents and suitability.Nothing herein shall constitute a warranty,expressed or implied,including any <br /> warranty of merchantability or fitness,nor is protection from any law or patent inferred.All patent rights are reserved.The foam product is combustible and must be <br /> protected in accordance with applicable codes.Protect from direct flame and spark contact,around hot work for example.The exclusive remedy for all proven <br /> claims is replacement of our materials. <br /> SIP/, <br /> DES \L L <br /> \�I US I A P MD MIAMI DADE COUNTY Q. <br /> ' � ""• EXTERIOR WALL SYSTEM COMPONENT <br /> USA ® IN ACCORDANCE WITH DIRECTORY <br /> C285 <br /> TO <br /> n tertek SEE BUILDING MATERIALS DIRECTORY <br /> ALSO CLASSIFIED IN ACCORDANCE WITH ASTM D1929 <br /> FILE R39899 <br /> 3315 E Division St <br /> Page 2 Of 2 PhArlington,TX 76011 I HUNTSMAN <br /> Phone:(817)640-4900 <br /> AN:20.000571 REV:09.09.22 www.huntsmanbuildingsolutions.com BUILDING SOLUTIONS <br />