Laserfiche WebLink
qUESNumber: <br /> ® Originally Issued: 03/08/2018 Revised: 05/03/2021 Valid Through: 03/31/2022 <br /> TABLE 4—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WITH HEATLOK®HFO INSTALLED <br /> ON THE EXTERIOR SIDE OF THE WALL ASSEMBLY <br /> Wall Component Materials <br /> Base Wall System(BWS)- 1. Concrete Wall. <br /> Use either 1,2,or 3 2. Concrete Masonry Wall. <br /> 3. 1 layer of 5/8-inch-thick Type X gypsum wallboard installed on the interior side of minimum <br /> 35/8-inch deep,minimum 25-gauge equivalent thick steel studs spaced a maximum of 24 inches <br /> on center. Lateral bracing installed minimum every 4 foot vertically or as required. <br /> Perimeter Fire Barrier System 1. Perimeter fire barrier system complying with Section 715.4 of the IBC shall be installed,as <br /> applicable,to fill the void between the edge of the concreter floor slab and the interior surface <br /> Use 1 or 2. of the exterior wall assembly. <br /> 2. Wall stud cavities shall be filled at each floor line with minimum 4 lb/ft3 mineral wool friction <br /> fit between steel wall studs,attached with Z-clips or friction fit. <br /> Interior Insulation—Use either 1. None <br /> 1,2,3,4 or 5 or combinations of 2. Full wall stud cavity depth or less of Heatlok®HFO Pro applied using exterior gypsum <br /> 3 with 4 or 3 with 5. sheathing of BWS 3 as the substrate and covering the width of the cavity and the inside of the <br /> steel wall stud framing flange.' <br /> 3. Fiberglass batt insulation(faced or unfaced) <br /> 4. Mineral wool insulation faced or unfaced <br /> Exterior Sheathing—use either 1 1. None(for BWS 1 or 2 above) <br /> or 2 2. 5/8-inch thick Type X exterior type gypsum sheathing for BWS 3 above <br /> Exterior Insulation 1. Maximum 31/2-inch thickness of Heatlok®HFO Pro(with Claddings 1-5,2-inch maximum air <br /> Use 1,2 or 3 gap between cladding and SPF). <br /> 2. Maximum 3-inch Heatlok HFO Pro SPF(with Claddings 6,7 and 8. Horizontal purlin every <br /> 2 feet maximum,no vertical Z girts. Purlin depth 1-inch deeper than SPF thickness. 1-inch <br /> maximum air gap between cladding and SPF. <br /> 3. Maximum 33/4-inch HeatLok HFO Pro(with Claddings 9-18,use coating—18 mils WFT <br /> DC315 with nine mils WFT Sherwin Williams Sher-Cryl HPA Topcoat with horizontal Z Girts <br /> 28 inches on center. 2-inch maximum air gap between cladding and SPF. <br /> Exterior wall covering—use any For use with Exterior Insulation 1 <br /> item 1-20 with specific <br /> insulation or coating—read 1. Brick—Standard type brick veneer anchors,installed a maximum of 24 inches on center, <br /> carefully. vertically on each stud with maximum 1-inch air gap between exterior insulation and brick. <br /> Brick to be standard nominal 4-inch thick clay brick installed in a running bond pattern using <br /> IMPORTANT Type S mortar. <br /> Use 1-5 only with Exterior 2. Stucco—Minimum 3/4-inch thick,exterior plaster and lath.A secondary water resistive barrier <br /> Insulation 1 (WRB)can be installed between the exterior insulation and lath. The secondary WRB shall not <br /> be full coverage asphalt or butyl based self-adhered membranes. <br /> Use 6,7 and 8 only with 3. Minimum 2-inch thick natural stone(granite,limestone,marble or sandstone)Any standard <br /> Exterior Insulation 2 non-open joint installation technique shall be used. <br /> 4. Minimum 0/2-inch thick concrete masonry unit(CMU),precast concrete or artificial cast <br /> Use 9-18 only with Exterior stone. Any standard non-open jointed method shall be used. <br /> Insulation 3 5. Minimum 11/4-inch thick terra cotta non-open jointed. Any standard non-open jointed <br /> installation technique shall be used. <br /> 1-inch maximum air gap <br /> between cladding and SPF for For use with Exterior Insulation 2 <br /> cladding 6,7 and 8 and <br /> insulation 2. 6. Vertical or horizontal flat 20 gauge minimum steel(or zinc galvanized steel)panels directly <br /> attached to horizontal purlin. Non-open joint. <br /> 2-inch maximum air gap with 7. STK 1000,STK 1500 Force Five,STK 2000,STK 2500 Force Five,STK 5000 or STK 5500 <br /> cladding 1-5 or claddings 9 Force Five panels or equivalent. Non-open joint. <br /> through 18. 8. Vertical or horizontal corrugated 20 gauge minimum steel(or galvanized steel)panels(2-inch <br /> maximum corrugation depth)directly attached to horizontal purlin with no air gap(between <br /> cladding and SPF)at the shallowest depth of corrugation profile. Non-open joint. <br /> For use with Exterior Insulation 3 <br /> Page 6 of 7 <br />