qUESEVALUATION REPORT <br /> ® Originally Issued: 03/08/2018 Revised: 05/03/2021 Valid Through: 03/31/2022 <br /> TABLE 2-ALTERNATIVE THERMAL BARRIER ASSEMBLY <br /> FIRE-PROTECTIVE COATING/COVERING' MAXIMUM SPF <br /> THICKNESS <br /> inch <br /> THEORETICAL FALLS CEILING <br /> TYPE MINIMUM D AND <br /> THICKNESS APPLICATION RATE VERTICAL OVERHEAD <br /> (COATINGS ONLY) SURFACES SURFACES <br /> DC315 2 18 mils WFT 1.1 gal/100 ft2 7.5 11.5 <br /> 12 mils DFT <br /> Blazelok TBX3 18 mils WFT 1.1 gal/100 ft2 7.5 11.5 <br /> 12 mils DFT <br /> For SI: 1 inch=25.4 mm,1 gallon=3.785 L,1 ft2=0.0929 m2 <br /> 'Fire-protective coatings and coverings shall be applied over all exposed SPF surfaces in accordance with the <br /> coating/covering manufacturer's instructions and this report. <br /> 2 International Fireproof Technology,Inc,recognized in IAPMO UES ER-499. <br /> 3ICP Construction,recognized in ICC-ES ESR-3997 <br /> TABLE 3—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WITH HEATLOK®HFO PRO IN WALL CAVITY <br /> Wall Component Materials <br /> Base Wall System(BWS)- 1. Concrete Wall. <br /> Use either 1,2,or 3 2. Concrete Masonry Wall. <br /> 3. 1 layer of 5/8-inch-thick Type X gypsum wallboard installed on the interior side of minimum 35/8- <br /> inch deep,minimum 25-gauge equivalent thick steel studs spaced a maximum of 24 inches on <br /> center. Lateral bracing installed minimum every 4 foot vertically or as required. <br /> Perimeter Fire Barrier System 1. Perimeter fire barrier system complying with Section 715.4 of the IBC shall be installed,as <br /> Use 1 and 2 applicable,to fill the void between the edge of the concrete floor slab and the interior surface of the <br /> exterior wall assembly. <br /> 2. 4 pcf mineral wool in each stud cavity at each floor line,attached with Z-clips or friction fit. <br /> Interior Insulation—Use either 1. None <br /> 1,2,3,4 or 5 or combinations of 2. Maximum of 35/8-inch thickness of Heatlok®HFO Pro applied to interior surface of BWS 1 and 2' <br /> 3 with 4 or 3 with 5. 3. Full wall stud cavity depth or less of Heatlok®HFO Pro applied using exterior gypsum sheathing of <br /> BWS 3 as the substrate and covering the width of the cavity and the inside of the steel wall stud <br /> framing flange. <br /> 4. Fiberglass batt insulation(faced or unfaced). <br /> 5. Mineral wool insulation faced or unfaced . <br /> Exterior Sheathing 5/8-inch-thick exterior type gypsum sheathing for BWS 3 above). <br /> Exterior wall covering z—use 1. Any non-combustible exterior wall covering material using any standard installation technique. <br /> either 1,2 or 3 2. Any non-combustible exterior wall covering system with a combustible water-resistive barrier <br /> (WRB)that has successfully been tested in accordance with NFPA 285. <br /> 3. Any combustible exterior wall covering system with or without a combustible WRB that has <br /> successfully been tested in accordance with NFPA 285. <br /> 4. Table 4 below—Exterior Insulation 2 only with Claddings 6,7 and 8 per Table 4 of this report(SPF <br /> as Exterior Insulation). Read notes carefully. <br /> 5. Table 4 below—Exterior Insulation 3(with coating)only with Cladding 9 thru 18 per Table 4 of this <br /> report SPF as Exterior Insulation).Read notes carefully. <br /> Flashing of window,door and As an option,flash around window,door and other exterior wall penetrations with limited amounts of <br /> other exterior wall penetrations maximum 12-inch wide flashing tape(acrylic,asphalt or butyl based)or liquid applied membrane material <br /> with or without fiber mesh reinforcement. <br /> Window Perimeter The window header,jambs and sill are covered with 0.080-inch aluminum flashing. The edges and top of the <br /> assembly were sealed with steel flashing. Windows and Doors shall be framed as required for the base wall. <br /> For SI: 1 inch=25.4 mm;1lb/ft3=16 kg/m3 <br /> 'Fireblocking per Section 718 of the 2018,2015 and 2012 IBC and Section 717 of the 2009 IBC and thermal barrier material requirements must <br /> be met for BWS 1 and 2,as required by specific wall construction details when combustible concealed space is created on the exterior side of <br /> the exterior wall assembly. <br /> 2 Combustible exterior wall coverings shall be installed in accordance with manufacturer's installation requirements. <br /> Page 5 of 7 <br />