CALEB WIDEN <br /> 2310 VIRGINIA AVE <br /> B2302-115 <br /> And Option 3.2 requires Air-source centrally ducted heat pump with minimum HSPF of 9.5. <br /> To qualify to claim this credit, the building permit drawings shall specify the option being <br /> selected and shall specify the heating equipment type and the minimum equipment <br /> efficiency. <br /> And to qualify to claim Option 5.3, the building permit drawings shall specify the option <br /> being selected and shall specify the water heater equipment type and the minimum <br /> equipment efficiency and, for solar water heating systems, the calculation of the minimum <br /> energy savings. <br /> I would like to suggest you reviewed detailed requirement for each of the options and you <br /> may find other options could be easier to archive than those you selected. <br /> 6. Kitchen and bathroom ventilation meet code requirement. However, on Page 11, this <br /> ventilation table is from 2015 code, but we are currently adopting 2018 version code. There <br /> is no need to copy and paste the table, you may specify what CFM ventilation you are using <br /> in floor plan on Page 4 floor plan. Changed to 2 CFM <br /> 7. No additional action. ID <br /> ECE <br /> �J(� + <br /> 8. No additional action. <br /> P 3 s <br /> 9. No additional action. i' n <br /> L 2li_73 �t,Jr9 <br /> 10. Please dimension the kitchen window location. Showing Kitchen Window.Location —"F9 <br /> cD <br /> KE T <br /> 11. On Page 6, in the Stair Section Detail Note, it is confused if you have skirt board or not. <br /> Please clarify. Also, please provide information that the handrail detail drawing could meet <br /> IRC 311.7.8.2 Handrail Projection, IRC 311.7.8.3 Handrail Clearance and IRC 311.7.8.5 Grip <br /> Size requirement. No Skirt boards on stairs, Railing height 36", Railing dimensions 1 1/4-2" round <br /> Railing Shall be continuous From toe of bottom tread to toe of top tread <br /> Structural (Reviewer: Cal Bearman) <br /> (Comments provided by Cal Bearman P.E., CBEARMAN@EVERETTWA.GOV) <br /> 1. The construction of the braced wall panels should be shown in the construction drawings. <br /> The locations identified on Page 4 are adequate, but the construction method is unclear. <br /> Section R602.10.4 and Table 602.10.4 provides the requirements for the construction <br /> methods. It appears that the wood structural panel method is being selected with 1/2"OSB <br /> installed. This method requires nailing per Table R602.3(3) which indicates 6d Common <br /> nails as the minimum size and spacing of 6" at the edges of the OSB panels and 12" in the <br /> field of the OSB panels. Please indicate on the drawings the construction method and nailing <br /> requirements for the braced wall panels. Put Nailing on plans typical wall Pg-6 <br /> 2. On Page 6, the Wall Schedule is not coordinated with the plans. Consider deleting this <br /> schedule as it does not appear to apply to this project. On Page 7, the Nailing Schedule is <br /> not coordinated with the plans. Consider deleting this schedule and replacing it with a <br /> general fastener schedule which should be provided per IRC Table R602.3(1). <br /> Nail,,., � <br /> 3. The deck guard design should comply with the Section R312.1. In the elevations drawings <br /> on Page 2, the deck guardrail is not shown on the West Side but is shown on the North <br /> © 3200 Cedar Street CD 425.257.8810 r, permitservices@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax �'�� everettwa.gov/permits <br /> Page 3of4 <br />