Laserfiche WebLink
James Bronder <br /> From: James Bronder <br /> Sent: Wednesday, June 14, 2023 3:45 PM <br /> To: 1605edgemoor@gmail.com <br /> Subject: Correction Notice 1 - B2304-014 <br /> Hi Devon, <br /> Building permit review comments are noted below. Please let me know if you have questions regarding these items. <br /> 1. Design calculations for deck joists appear to assume a spacing of 12" oc. Plan sheets appear to show a deck <br /> joist spacing of 16" oc. Please verify if the deck joists on the plans are intended to be 12" oc to match the <br /> design calculations or if the calculations are to be adjusted to 16"oc. IRC 106.1.1, R301.5. <br /> 2. Please indicate that the design live load is 60 psf at decks. This appears to be missing from the plans. IRC <br /> 106.1.1. <br /> Thank you, <br /> James Bronder, P.E., S.E. <br /> Lii <br /> IIIAssociate Engineer—Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2"d Floor, Everett, WA 98201 <br /> EVERETT Phone Hours: M/W/Th: 8 a.m.—12 p.m & 1 p.m.—3 p.m. <br /> everettwa.gov/permits I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> 1 <br />