Laserfiche WebLink
LEGEND <br /> O O EXISTING WALL TO REMAIN W F u z <br /> w <br /> EXISTING WALL TO BE �v $w <br /> DEMOLISHED a m <br /> EXISTING ITEM TO BE z o <br /> DEMOLISHED w <br /> (CASEWORK,EQUIPMENT, <br /> DOOR,ETC) <br /> NO WORK IN SHADED ARE NEW INTERIOR WALL <br /> w, <br /> \ O 4 CONSTRUCTION <br /> IASSEMBLY TYPE <br /> �0 FLOOR ELEVATION 00 <br /> Y 0 0 <br /> \ L � <br /> I / <br /> �# ELEVATION MARKER <br /> y 3 <br /> SECTION MARKER <br /> O u <br /> / # DETAIL MARKER <br /> OA DOORTAG 7 <br /> m 3 <br /> �� ✓ WINDOW TAG <br /> / FIRE EXTINGUISHER L <br /> \ / >_ E iJ <br /> W <br /> B NO WORK SHADED cl) � <br /> NOTES: E Lu <br /> 1. CONTRACTOR SHALL DIVERTAS MUCH OF THE (j � <br /> DEMOLISHED MATERIALS FROM THE LANDFILL AS <br /> POSSIBLE BY MEANS OF RECYCLING,DONATION,ETC. <br /> PATCH& <br /> PRIMBFFICEI PATCH& 2. WALLS SHALLBE PATCHED/REPAIREDAS REQUIRED. <br /> Z \ REPAIR ALL FINISHES TO MATCH EXISTING,UNO. <br /> 90 6F 3,ALL(E)DOORS&HARDWARE TO REMAIN,UNO. <br /> ��� OP NFIL VAO� �� 1 4. DIMENSIONS ARE TO FACE OF FINISH OF EXISTING <br /> WALLS AND FACE OF FRAMING OF NEW WALLS,UNO. Ln <br /> PATCH& \ 2� 5. IN SUITE CASEWORK,FIXTURES,FURNITURE& n <br /> REPAIR , FINISHES SHALL BE PROVIDED BY OWNER AND <br /> \ / / SHOWN ON PLAN FOR REFERENCE ONLY. U N <br /> cc <br /> 6. ELECTRICAL,MECHANICAL,AND PLUMBING SHALL BE <br /> \ \ 10 <br /> PATCH& BY DESIGN-BUILD UNDER DEFERRED SUBMITTALS. Q <br /> PRIVATE'OFFICE 2 REPAIR ANY MEP SHOWN IS FOR REFERENCE ONLY. N <br /> / 61 SF 7. REFER TO ENLARGED PLANS ON SHEET A4 FOR <br /> DIMENSIONS&ADA CLEARANCES NOT SHOWN HERE. o <br /> \ � \ PATCH& B. CONTRACTO RR SHALL INSTALL BLK'G AT Ns,TOILET A 0 <br /> 5 7Q <br /> g \ 2> PROVIDE CORNER di< \ REPAIR ^ ACCESSORIES,CASEWORK,& PLIANCES. m <br /> $ GUARD(CG)TYP. <br /> $ m PATCH& <br /> REPAIR D \\,, H co <br /> CONFERENCE ROOM \ PATCH& Y 'n � <br /> noo ✓/, KITCHEN L. REPAIR ( 1 O <br /> `J w <br /> o \ 238 SF \ 110G \ <br /> 0 696E F S _ <br /> PATCH& Z <br /> INFILL REPAIR V = <br /> OPENING z >� <br /> \ / PROVIDE CORNER INFILL L v J > <br /> GUARD(CG)TYP. OPENING O Q <br /> \ \ \ PATCH& Q <br /> 0' REPAIR 3 ' m N w <br /> /✓ L n <br /> PATCH&\ ` <br /> REPAIRto <br /> \ <br /> \ STORAGE ROOM <br /> noI <br /> OPEN OFFICE <br /> „oc <br /> $E, 1,54 SF <br /> PATCH& <br /> \ \ PROVIDE�ORNER / REPAIR <br /> V GUARD(CG)TYP. <br /> INVENTORY ROOM a c <br /> \ oA <br /> 3 322 SF <br /> o <br /> / v v WALL ASSEMBLIES <br /> / V / EXECUTIVE OFFICE <br /> INFILL <br /> zm 6F OPENING W 1 1-HOUR RATED INTERIOR WALL <br /> 518"TYPE'X GYPSUM WALLBOARD <br /> \ \ 3 518"METAL STUDS @ 16"O.C.wl <br /> \ PATCH& \ SOUND BATT INSULATION INFILL <br /> REPAIR <br /> 5l8"TYPE W GYPSUM WALL BOARD <br /> 2 WZ 518"TYPAEX'GYPSUM WALL NO BEARING N-LOAD <br /> INTERIOR BO BOARD <br /> B <br /> 3 SO METAL STUDS @ 16"O.C.wl <br /> SOUND BATT INSULATION INFILL <br /> 5l8'GYPSUM WALL BOARD <br /> 8/21/24 <br /> PROPOSED FLOOR PLAN <br /> FIRST FLOOR SUITE 110 PROPOSED FLOOR PLAN A1 .2 <br /> f��.2 1/4" = 1,_0" o z a• e• <br />