My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY AINSWORTH INC 2025-04-08
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
AINSWORTH INC
>
906 SE EVERETT MALL WAY AINSWORTH INC 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 2:36:00 PM
Creation date
3/24/2025 9:52:13 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
AINSWORTH INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application <br /> Although photoelectric detectors have a wide range of fire sensing capabilities they are best suited for detecting slow,smoldering fires. <br /> The table below shows six standard test fires used to rate the sensitivity of smoke and heat detectors.The table indicates that no single <br /> sensing element is suited for all test fires. <br /> EDWARDS recommends that this detector be installed according to latest recognized edition of national and local fire alarm codes. <br /> SIGA-HRS and <br /> SIGA-HFS Rate-of- SIGA-PHS SIGA-IPHS <br /> Test Fire SIGA-PS Photo Rise/Fixed Temp. Photo Heat 3D Ion/Photo/Heat 4D <br /> Open Wood unsuitable optimum very suitable optimum <br /> Wood Pyrolysis optimum unsuitable optimum optimum <br /> Smouldering Cotton optimum unsuitable optimum optimum <br /> Poly Urethane Foam very suitable suitable very suitable optimum <br /> n-Heptane very suitable very suitable optimum optimum <br /> Liquid Fire without unsuitable optimum very suitable very suitable <br /> Smoke <br /> Typical Wiring <br /> The detector mounting bases accept#18 AWG(0.75mm2),#16(1.Omm2), #14 AWG(1.5mm2), and#12 AWG(2.5mm2)wire sizes. <br /> Note: Sizes#16 AWG(1.Omm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog <br /> sheet for detailed wiring requirement specifications. <br /> Standard Detector Base,SIGA-SB,SIGA-SB4 Relay Detector Base,SIGA-RB,SIGA-113134 <br /> Normally-Normally- Term Descri tion <br /> Remote LED Term Description Common Closed Open p <br /> Max resistance 2 DATA IN/OUT(+) 2 DATA IN/OUT(+) <br /> per wire 3 Not Used 3 Common <br /> + must not exceed 4 DATA IN(-) 4 DATA IN(-) <br /> 10 Ohms 4 Remote LED(-) O o 6 5 Not Used <br /> 5 Remote LED(+) ® 6 Normally-Closed <br /> 6 Not Used ® 7 DATA OUT(-) <br /> 7 DATA OUT(-) <br /> CONTACT RATING <br /> O� 1.0Amp@30VDC <br /> DATJN(-) z o DATA OUT(-) (Pilot Duty) <br /> DATA IN I-) a DATA OUT I-I <br /> DATA IN(+) DATA OUT(+) <br /> DATA IN 1+I DATA OUT(A From Signature Controller To Next Device <br /> From Signature Controller To Next Device or Previous Device <br /> or Previous Device <br /> Isolator Detector Base,SIGAAB,SIGA-1134 Audible Detector Base,SIGA-AB4G <br /> Term Description <br /> 1 Not Used Volume setting Tone setting <br /> O6 2 DATA IN/OUT(+) Default=High g volume Default=Temporal pattern <br /> 5 <br /> ° ® 3 DATA IN(-) Cut for low volume Cut for steady tone <br /> ® ®o 4 Not Used U <br /> 5 Not Used <br /> °® 6 DATA OUT(-) <br /> ® o 7 Not Used 44 -- <br /> To configure output volume <br /> or tone,cut the circuit board <br /> DATA IN() z DATA OUT() as shown. <br /> 24 Vdc in _ 24 Vdc out <br /> From power supply or + +To next base or EOL relay <br /> DATA IN(+) DATA OUT(+) previous base <br /> From Signature Controller To Next Device Data in <br /> or Previous Device From Signature controller or Data out <br /> + +To next Signature device <br /> previous device <br /> Page 3 of 4 DATA SHEET E85001-0269 <br /> Not to be used for installation purpo� Issue 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.