5. The building includes 2 apartments on the second floor which were permitted as construction type <br /> V-1 hour in 1982. The floor/ceiling assembly between the first and second floor shall remain as a 1- <br /> hour separation. Please describe and show all work that will be done on the ceiling/floor above. <br /> 6. Existing buildings undergoing alterations and a change of occupancy are subject to the following: <br /> a. All portions of the building being altered are subject to current codes for the new work. <br /> Existing building elements that are not being altered must comply with code in effect during <br /> original construction. <br /> b. Energy upgrades to any system being altered, including heating,water heating, lighting, etc. <br /> See WSEC-0503.1 and C505.3. <br /> c. Accessibility upgrades to the extent technically feasible. See IEBC 306.5 and 306.7. <br /> Architectural,Accessibility& Energy <br /> 7. Please provide and show the locations of accessible seating and counter access. See ANSI 117.1- <br /> 2017 Section 902 and 904. <br /> 8. Please show all accessibility features in the bathroom, including grab bars and clearance under the <br /> sink. See ANSI 117.1-2017 Section 604 and 606. <br /> 9. The exit out the back should swing out in the direction of travel. See IBC 1010.1.2.1. <br /> 10. Please show the remainder of the exit corridor out to the alley, including the length of the corridor <br /> to the exterior exit door and existing or new lighting. See IBC 107.2.3. <br /> 11. Show exit signs on the back alley door and throughout the route to the alley. See IBC 1013.1. <br /> 12. Show emergency lighting on battery backup. See IBC 1008.1. <br /> 13. Please indicate how the space is going to be heated. See IBC 1203.1. <br /> 14. The insulation shown on the drawings is insufficient. Please reference the minimum insulation <br /> requirements of WSEC-Table C402.1.4. <br /> 15. If gas heat is being used in the space, the requirements are modified. See WSEC-C401.3. <br /> 16. Please indicate source of hot water. See WSEC-Table C404.2 and C404.2.1. <br /> 17. Lighting controlled by occupancy sensor for the bathroom and storage rooms. See WSEC-C405.2.1. <br /> 18. Please provide lighting calculation indicating compliance with WSEC-Table C405.4.2.1(1). <br /> For a full list of applicable codes adopted by the City of Everett, please see the Construction Codes (PDF). <br /> If you have any questions or require additional clarification, please contact us. <br /> Sincerely, <br /> — Scott SchreffIer, RA <br /> Senior Building Plans Examiner I Permit Services <br /> 425.257.8810 1 3200 Cedar Street, 2nd Floor, Everett, WA 98201 <br /> EVERETT Phone Hours: M/W/Th: 8:30 a.m.—12 p.m & 1 p.m.—3 p.m. <br /> everettwa.gov/permits I onlinepermits.everettwa.gov I Facebook I Twitter <br /> S:\#Common\Bldg Permit Reviews\1_Commercial Reviews\2814 Rucker-Coffee shop\B2408-025_1stReviewLetter_09.09.2024.docx <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett, WA 98201 everettwa.gov/permits <br /> Page 2 of 2 <br />