Laserfiche WebLink
13. Please indicate how the space is going to be heated. See IBC 1203.1. <br /> There is an existing electric fan coil unit. Arcoaire Model FEM4X4800BL. This <br /> is also shown on sheet A101. <br /> 14.The insulation shown on the drawings is insufficient. Please reference the minimum <br /> insulation requirements of WSEC-Table C402.1.4. <br /> All exterior walls are existing and modifications to the walls are not a part of <br /> this scope of work. No existing insulation was removed or disturbed. <br /> 15. If gas heat is being used in the space, the requirements are modified. See WSEC- <br /> C401.3. <br /> The heat unit is electric. See item 13 for more information. <br /> 16. Please indicate source of hot water. See WSEC-Table C404.2 and C404.2.1. <br /> The water heater is now shown in the closet outside the restroom on sheet <br /> Al 00. It is a tankless water heater. <br /> 17. Lighting controlled by occupancy sensor for the bathroom and storage rooms. See <br /> WSEC-C405.2.1. <br /> The switches are shown on sheet A100 and listed as occupancy sensor <br /> switches in the restroom and storage room. <br /> 18. Please provide lighting calculation indicating compliance with WSEC-Table <br /> C405.4.2.1(1). <br /> Calculations are shown below. <br /> Interior Lighting Power Allowances-Building Area Method-Table C405.4.2(1) <br /> Building Area Type: Dining: Bar lounge/leisure <br /> Allowable LPD (w/ft2): 0.79 <br /> Marcel square footage: 1,235 SF <br /> Existing track light quantity: 24 heads <br /> Each track light head bulb wattage = 6.5 watts <br /> Existing LED can light quantity: 3 fixtures <br /> Existing LED can bulb wattage = 15 watts <br /> New wall sconce quantity: 4 fixtures <br /> Each wall sconce bulb wattage = 10 watts <br /> Existing fixture wattage-(24 x 6.5) = (3 x 15) = 201 watts <br /> New fixture wattage-4 x 10 =40 watts <br /> Total fixture wattage = 241 watts <br /> LPD calculation-241 watts/ 1,235 SF=0.195 w/ft2 <br /> Thankyou, <br /> Scott Hulme <br />