Permit #: B2408-013, Second Building Review <br /> August 27, 2024 <br /> wall,the sink,the range, hood, and hood fan. Please make sure that these items are located and <br /> labeled on the existing plan. <br /> o Please provide a "proposed" floor plan showing all work that was performed to the house. Please <br /> label the rooms, at minimum the kitchen and adjacent rooms. Please include the dimensions of the <br /> remodeled kitchen and adjacent rooms. One the proposed floor plan, please include a note that <br /> describes any new items including but not limited to drywall,the new framed non-bearing opening, <br /> the new sink,the new range, hood, and hood fan. Please make sure that these items are located and <br /> labeled on the "proposed" plan. <br /> Architectural (Reviewer: Anita Chen) <br /> Codes:2021 International Residential Code(IRC), 2021 Washington State Energy Code-Residential <br /> Provisions(WSEC-R). Code sections are hyperlinked. <br /> 2. Please provide a range hood fan and label the fan with the CFM on the proposed plan. 160 CFM <br /> minimum for an electric range and 260 CFM for a gas range. (IRC M1505.4.4.3) <br /> 3. Please provide location of the air exhaust opening for the hood fan (IRC M1504.3). <br /> Residential Exhaust Openings <br /> MECHANICAL AIR INTAKE <br /> Exhaust opening to be not less than 10' <br /> where not less than 3'above <br /> PROTECTION(R303.6) <br /> 10'min Intake and exhaust openings shall be <br /> protected with corrosion resistant <br /> screens or louvers(1/4"min to 1/2"max <br /> openings).Openings shall be protected <br /> against weather conditions.Outdoor <br /> ® 3'min openings shall meet the provisions for <br /> J, exterior wall opening protectives. <br /> 3'min <br /> (� 3'min <br /> AIR EXHAUST OPENING <br /> Shall terminate not less than 3'from <br /> Operable openings property line,air intake openings or <br /> �3'min operable windows and doors <br /> Areas not permitted <br /> �1 <br /> �3'm i n I 3'mi n <br /> Exhaust air shall not be ' <br /> directed onto walkways <br /> (R303.5.2) <br /> 4. Please provide opening protection for the air exhaust opening with "corrosion-resistant screens, louvers <br /> or grilles having an opening size of not less than 1/4 inch (6 mm) and a maximum opening size of 1/2 <br /> inch (13 mm), in any dimension." Please provide a note of what will be provided in the proposed plan. <br /> (IRC R303.6.) <br /> 5. Please fill any ceiling/attic, exterior wall or floor cavities that were exposed during construction. Please <br /> provide R-21 insulation for 2x6 exterior walls or R-15 for 2x4 exterior walls. If applicable, please fill any <br /> ceiling/attic cavities that were exposed during construction with R-60 insulation. Also, if applicable, <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />