Laserfiche WebLink
Permit #: B2407-055, First Building Review <br /> July 25, 2024 <br /> Submittal documents should contain sufficient information and detail to review the proposed project for <br /> compliance with the adopted building codes. Upon submittal of the revised documents,your application <br /> will be given priority and the review will recommence. <br /> General (Reviewer:Anita Chen) <br /> 1. (IRC 106.1.1) Please provide details of roof to beam or building connection at the upper end of roof. <br /> Sheet 9 shows a"roof ledger" and Sheet 10 shows a section without a ledger and a roof independent of <br /> the existing building. <br /> Architectural (Reviewer: Anita Chen) <br /> 2. (IRC R311.7.8) Please provide a handrail for the stairs. <br /> a) Please show handrail height(34 inches minimum, 38 inches maximum per IRC R311.7.8.1) <br /> b) Please provide appropriate grip size for handrail at stairs per IRC R311.7.8.5. <br /> 3. (IRC R507.3) Please provide for drainage at PT posts. (See markups below.) <br /> Provide +/- 1 : 12 slope <br /> -':- for drainage <br /> Z - POST <br /> TYP 12 -GAS IN-PLACE <br /> P544 OST BASE <br /> +/- 1 <br /> D URSED SOIL <br /> i <br /> A <br /> HOLE-FORM CONCRETE <br /> Z FOOTINGS(50NOTUBE <br /> IF APPLICABLE) <br /> iq 42)1/2"REBAR #4 <br /> -FOOTING SET 6" <br /> ,.a. ABOVE GRADE <br /> 5EE PLAN FR05T LINE-18"DEPTH <br /> 3 SECTION FOOTING <br /> 03 3/4"= 1' <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 3 <br />