My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
620 112TH ST SE SPACE 1 2025-11-07
>
Address Records
>
112TH ST SE
>
620
>
620 112TH ST SE SPACE 1 2025-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2025 1:48:32 PM
Creation date
3/24/2025 10:55:15 AM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SE
Street Number
620
Unit
SPACE 1
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit #: B2407-055, First Building Review <br /> July 25, 2024 <br /> Z ___------4X P.T.POST <br /> — � UNDISTURBED 501E <br /> ((1 <br /> HOLE-FORM CONCRETE <br /> t__EXTEND PT POST1 11=1 FOOTINGS(50NOTUBE IF <br /> TO GRAVEL BELOW z :. I=III APPLICABLE) <br /> (FOR DRAINAGE) ; I1111I11 -50UARE(CUBICREBARCAGE) <br /> 44)VERTICAL LONGITUDINAL1/2" <br /> IRC FIGURE R507.3 r 111111 REBAR #4 <br /> 4n .1 " ^• o_- -02)HORIZONTAL STIRRUPS 112" <br /> REBAR#3 @ 12"O.G.MAX <br /> II -FOOTING SET b"ABOVE GRADE <br /> 5EE PLAN FROST LINE-15"DEPTH <br /> 4" GRAVEL <br /> r41 SECTION Q FOOTING <br /> 04 3/4"=1' <br /> 4. (IRC R507.3.1) Please resize center footings shown at 18" diameter.The tributary area is about 27 sq. ft <br /> and would need to be rounded to 40 sq ft (extrapolation is not permitted per Table R507.3.1 Note a). <br /> The footing would need to be 21 inches in diameter. <br /> 5. (IRC R507.9.1.3) Please clarify through details and notes how the deck will be fastened to ledger. See <br /> figures R507.9.1.3(1) and R507.9.1.3(2). <br /> 6. (IRC Table R602.7(3))The 4x10 "roof beam" spanning 14'-5 %" does not meet the IRC prescriptive <br /> method. Please provide additional supports or a different beam size or calculations done by a licensed <br /> engineer. <br /> 7. (IRC R905.10.2) Please provide appropriate roof slope for metal roof.To slope%"to 12",the proposed <br /> metal roof would need to be either a "lapped, nonsoldered-seam metal roofs with applied lap sealant" <br /> or a standing-seam roof. It is not clear in the drawing set if the proposed metal roof was either of these. <br /> This review has been performed for general compliance with the building codes as adopted and amended by <br /> the state of Washington and the city of Everett. Corrections and comments made during the review process <br /> do not relieve the project from compliance with code and permit requirements. The designers-of-record are <br /> responsible for a complete design in accordance with the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Anita Chen <br /> Building Plan Review Technician <br /> (425) 257-7805 <br /> AChen@everettwa.gov <br /> IS3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.