Laserfiche WebLink
Operable Partitions <br /> • I 3030SPECIFICATIONS <br /> K II <br /> 1.01 WORK INCLUDED <br /> A.Operable Wall System shall be furnished,installed and serviced F.ASTM C 423:Standard Test Method for Sound Absorption and <br /> by KWIK-WALL's authorized distributor,in compliance with Sound Absorption Coefficients by the Reverberation Room Method. <br /> the architectural drawings and specifications contained herein. G.CCC-W-4o8A-D:Federal Specification which applies to Vinyl <br /> Coated Wall Coverings. <br /> 1.02 RELATED WORK H.CFFA-W-ioi-B:Chemical Fabrics and Film Association Quality <br /> A.Structural Support:Structural support system required for Standard for Vinyl Coated Fabric Wall Coverings. <br /> suspending the operable wall shall be designed,installed and I. ATTM E 2190:Certification and testing for Insulated Glass <br /> pre-punched by others,in accordance with ASTM E 557 and inserts. <br /> KWIK-WALL's shop drawings. <br /> B.Insulation:Sound insulation and baffles for the plenum area 1.06 SUBMITTALS <br /> above the track system,under the permanent floor,inside air A.KWIK-WALL shall provide written technical information and <br /> ducts passing over or around the operable wall,and in permanent related detail drawings,which demonstrate that the products <br /> walls adjoining the operable wall system shall be by others,in comply with contract documents for each type of operable <br /> accordance with ASTM E 557. partition specified. <br /> C.Opening Preparation:Proper and complete preparation of the B.KWIK-WALL shall provide detailed engineering drawings <br /> operable wall system opening shall be by others in accordance featuring track plan,panel elevation,horizontal and vertical <br /> with ASTM E 557,and shall include floor leveling;plumbness of details and beam punching template as required. <br /> adjoining permanent walls;substrate and/or ceiling the <br /> enclosures for the track system;and the painting and finishing C.KWIK-WALL shall provide written test report of the independent <br /> of trim and other materials adjoining the head and jamb areas of acoustical testing laboratory certifying the attainment of the <br /> the operable wall.Any permanent wall(s)receiving an adjustable specified STC rating,upon request. <br /> or fixed wall jamb will require internal structural blocking in D.KWIK-WALL shall provide written instructions specifying the <br /> order to secure the jamb to the permanent wall.Refer to a copy proper operation and maintenance of the operable wall system. <br /> of the shop drawings for additional details. E.KWIK-WALL shall provide a color selector demonstrating the <br /> manufacturer's selections of the specified finish material.Samples <br /> 1.03 SYSTEM DESCRIPTION shall consist of actual swatches of the specified finish material. <br /> A.The operable wall system shall consist of Hinged Pairs operation, <br /> featuring panels hinged together in evenly matched pairs(groups 1.07 DELIVERY, STORAGE AND HANDLING <br /> Of two(2)),unless otherwise specified. A.Panels shall be individually wrapped in a protective plastic <br /> B.The operable wall system shall consist of acoustically rated panels covering to keep panels clean during delivery,storage <br /> tested in accordance with ASTM E go and ASTM E 413 test and handling. <br /> procedures,and shall have achieved a STC rating as specified B.Panels shall be stored on edge and above the floor on cushioned <br /> herein(see"Acoustical Performance"article listed under blocking in a dry and ventilated area,protected from humidity <br /> Part 2-Products). and temperature extremes. <br /> 1.04 QUALITY ASSURANCE 1.08 SEQUENCING/SCHEDULING <br /> A.The operable wall shall have been tested in an independent A.Beam Punching:KWIK-WALL shall provide beam punching <br /> acoustical testing laboratory in accordance with ASTM E go and template drawing detailing the anchor locations for the <br /> ASTM E 413 test procedures. suspended track system(as required for Drop Rod Mounting),as <br /> B.The operable wall panel construction and finish materials shall required for the fabrication and installation of structural overhead <br /> consist of Class A rated materials in accordance with ASTM E 84. support by others. <br /> C.The operable wall shall be installed by the KWIK-WALL's B.Track Installation:Scheduling of operable wall track installation <br /> authorized distributor in accordance with ASTM E 557. shall occur after structural overhead support has been properly <br /> and completely fabricated and installed by others. <br /> 1.05 REFERENCES C.Panel Installation:Operable wall panel installation shall occur <br /> A.ASTM E go:Laboratory Measurement of Airborne-Sound after fixed wall substrate construction is properly and completely <br /> Transmission Loss of Building Partitions. installed by others,as required <br /> B.ASTM E 413:Determination of Sound Transmission Class(STC). 1.09 WARRANTY <br /> C.ASTM E 557:Architectural Application and Installation of A.KWIK-WALL shall warrant each operable wall panel and its <br /> Operable Partitions. component parts to be free from defects in material and <br /> D.ASTM E 84:Surface Burning Characteristics of Building Materials. workmanship for a period of five(5)years from the date of <br /> delivery to the original purchaser,when installed by an authorized <br /> E.ASTM A 653:Specification for General Requirements for Steel KWIK-WALL distributor. KWIK-WALL also warrants the fixed <br /> Sheet,Alloy-Coated(Galvannealed)by the Hot Dip Process. top seals,track,carriers,and its component parts to be free from <br /> defects in material and workmanship for a period of ten(io) <br /> years.(see actual warranty on Page 16 for details and limitations). <br /> 2 <br /> Dimensions in[I are millimeters.Contact your local distributor for additional assistance or visit www.kwik-wall.com 04-23 <br />