2 3 4 5 6 <br /> Wall Legend General Notes- Residential Floor Plans Keynote Legend <br /> A. EXTERIOR DIMENSIONS ARE TO THE OUTSIDE FACE OF STUDSUNLESS M. CONTRACTOR TO CONFIRM ALL CLEARANCE REQUIREMENTS AS NOTED ON <br /> MTL.FRAMED WALL OTHERWISE NOTED. DETAIL A6.01. Key Value Keynote Text <br /> B. DIMENSIONS AT UNIT DEMISING WALLS ARE TO CENTERLINE OF WALL. N. REFER TO DETAILS ON SHEET A6.01 FOR TYPICAL DOOR CLEARANCES. <br /> STANDARD WALL C. INTERIOR DIMENSIONS ARE TO THE FACE OF STUDS AT FRAME WALLS,AND TO O. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS AT FIRE RATED WALLS, 27 3200.A TWO-WAY COMMUNICATION SYSTEM W/AUDIBLE AND VISIBLE <br /> CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED. INCLUDING BUT NOT LIMITED TO PIPING,DUCTS,CONDUIT,ETC.,WITH SIGNALS <br /> D. DIMENSIONS LOCATING DOORS,WINDOWS AND RELIGHTS ARE TO NOMINAL FIRESTOPPING PER I.B.C.REQUIREMENTS. <br /> MASONRY OPENING OR TO FINISH OPENING UNLESS OTHERWISE NOTED. P. SEE EXTERIOR ELEVATIONS FOR WINDOW AND LOUVER TYPES AND DETAILS. DYKEMAN <br /> INSULATED OR ACOUSTIC WALL E. SEE WALL TYPES ON SHEET A1.01 FOR TYPICAL WALL CONSTRUCTION Q. SEE ENLARGED PLANS FOR ADDITIONAL DIMENSIONAL AND NOTE <br /> ASSEMBLIES. INFORMATION. <br /> F. ALL NON-BEARING WALLS ARE FULL HEIGHT TO UNDERSIDE OF FLOOR ABOVE. R. TYPICAL WALLS AT UNIT INTERIORS ARE WALL TYPE WIN 411 UNLESS NOTED <br /> WOOD FRAMED WALL G. APPLY TWO(2)CONTINUOUS SEALANT BEADS BENEATH STUD TRACK AT ALL OTHERWISE.FOR TYPICAL WALLS AT UNIT INTERIORS REFER TO UNIT 201 ON ARCHITECTURE + DESIGN <br /> EXTERIOR STUD WALLS. SHEET A4.22A. <br /> H. CONTRACTOR SHALL PROVIDE CONTINUOUS HORIZONTAL BLOCKING AT ALL S. SENSORY ACCESSIBLE UNITS PROVIDED PER UFAS SECTION 4.28.2 AND 4.28.3 <br /> STANDARD WALL WALL MOUNTED LAVATORIES,DRINKING FOUNTAINS,CASEWORK,MIRRORS, WITH: <br /> HANDRAILS,ETC.REFER TO ARCHITECTURAL INTERIOR ELEVATIONS AND a. AUDIBLE ALARMS-AUDIBLE EMERGENCY ALARMS,SHALL PRODUCE A <br /> MECHANICAL DRAWINGS. SOUND THAT EXCEEDS THE PREVAILING EQUIVALENT SOUND LEVEL IN THE <br /> I. SEE DETAIL SHEET A6.01 FOR TYPICAL MOUNTING HEIGHTS FOR WALL ROOM OR SPACE BY AT LEAST 15 DECIBELS OR EXCEEDS ANY MAXIMUM <br /> E INSULATED OR ACOUSTIC WALL MOUNTED ACCESSORIES AND EQUIPMENT. SOUND LEVEL W ITH A DURATION OF 30 SECONDS BY 5 DECIBELS, E <br /> J. SEE INTERIOR DESIGN DRAWINGS FOR TRANSITION DETAILS AND THRESHOLDS. WHICHEVER IS LOUDER.SOUND LEVELS FOR ALARM SIGNALS SHALL NOT <br /> K. ELECTRICAL PANELS,TRANSFORMERS,BOILERS,AIR HANDLING UNITS,AND EXCEED 120 DECIBELS. • <br /> DUCTWORK WHEN SHOWN,ARE IN <br /> FOR CONTRACTOR CONVENIENCE. b. VISUAL ALARMS-ELECTRICALLY POWERED INTERNALLY ILLUMINATED <br /> SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR SPECIFIC SIZES AND EMERGENCY EXIT SIGNS SHALL FLASH AS A VISUAL EMERGENCY ALARM IN <br /> LOCATIONS. CONJUNCTION WITH AUDIBLE EMERGENCY ALARMS.THE FLASHING <br /> L. SEE MECHANICAL AND ELECTRICAL PLANS FOR CEILING MOUNTED EQUIPMENT. FREQUENCY OF VISUAL ALARM DEVICES SHALL BE LESS THAN 5 HZ.IF SUCH <br /> ALARMS USE ELECTRICITY FROM THE BUILDING AS A POWER SOURCE, <br /> THEN THEY SHALL BE INSTALLED ON THE SAME SYSTEM AS THE AUDIBLE <br /> EMERGENCY ALARMS. <br /> • <br /> A G <br /> 142'-11" <br /> *17 <br /> 1"@EXT F.O.STUD A.3 <br /> 5'-6" 16'-01/2" 40'-10" 15'-10" 15'-10" 15'-10" 12'-6" 20'-61/2" 1'-51/2"@EXT F.O.STUD <br /> N It <br /> W <br /> 2 P P 2 PW P P PW 1 Q <br /> D 1 A3.12 CS A3.1 A3.11 L <br /> LL D <br /> X • • <br /> � 4.238 A4.51 4.23 � <br /> — � - - - - - - - - - - - - - - - - - - - - - - - ----------- <br /> - - - - - - ----_— _ — _ _ — — — _ - - - - - - - - - - - - HOPEWORKS <br /> - - STAIR42 J STATION 2 <br /> 2 BED Unit 1BED Unit - S7#2 STUDIO Unit 1BED Unit 1BED Unit 1BED Unit STUDIO Unit <br /> Type-B Type-B Type-13 TypaB_ T B TypaB Type-B <br /> 308 307 - 306 3 5 3 3 302 <br /> 528 SF 359 SF r �09 SIF 39 SF 391 SF 397 SF 399 SF FOR <br /> II F --1 00 O r - �0 Or n Ir AIL, HOPEWORKS & <br /> L J L- - I Y HOUSING HOPE <br /> to <br /> I� L <br /> C71 L �I Oo °o 2BEDUnit <br /> AT <br /> II _ TRH �° F °SF �1 3315 BROADWAY, <br /> aesFJ L — F 5i EVERETT, WA <br /> J <br /> 4'-0"@EOS 273200.A )®) - CONFORMED SET <br /> o ® 05/15/2018 <br /> -- - _ - 0 <br /> �I LAUND Y <br /> ELEV#1 1 L `�EQ EQ EQ EQ EQ This drawing is: <br /> IT 101 SF (z7 <br /> 325 AMENITY I <br /> C ® z v' �� ¢ AMENITY <br /> f 1.Copyright 2017 Dykeman,Inc. C <br /> A3.10 323 <br /> SF cD y �� m 452 SF 2.The Architect's Instrument of Professional Service. <br /> 3.For use on this project only.Obtain Architect's <br /> III G c a i) written permission for any other use or reproduction. <br /> K <br /> STUDIO Unit '• <br /> Typo - JL J L - J ti' n <br /> III 330 sF — F O — 2016-025 <br /> a <br /> 5'-7"FROM COLUM CTR TO FOS OPEN BELOW 5'-7"FROM COLUM CTR TO FOS O -1 <br /> A3.10 I x (CO(COURTYARD @ L2) - If STORAGE I • <br /> O -i• m L <br /> •Ta 55 SF MARK DATE DESCRIPTION <br /> STUDIO Unit REF A L <br /> J. REFER TO LANDSCAPE O v' I 9 <br /> 11/16/2017 Pricing Set <br /> T3108 FOR PAVERS&LAYOUT I 12/08/2017 Permit Set <br /> L - o 02/08/2018 Bid Set <br /> 327 SF L J� C 1BED Unit - ADD#1 0222/2018 Addendum#1 <br /> 322 BPR 03/12I2018 BLDG Permit Revision <br /> Ea—-—-— A J 400 SF J CS 05/14/2018 Conformed Set <br /> z EQ <br /> — STUDIO Unit — L J L o J .— — EO — — — — — — — — — — — — <br /> Type-B L - J EO._' r � <br /> 311 _ L - J L - J ST'tyUDIOpe-Unit <br /> 328 SF �L k_„ L B JJ <br /> 0 J l <br /> III _ 321 <br /> J� 306 SIF <br /> L I <br /> IQ I <br /> _ a <br /> _ I STUDIO Unit ORA (� po o <br /> B III TYPe-A L - 7.. r = 328 B <br /> n�I o <br /> r J 2 D Unit -JI-SOLAR PANEL <br /> 312 L - JTyLN-B J l YP •• <br /> 373 SF ABOVE T O O _ <br /> 1i <br /> J 320 <br /> C9 671 SIF I PRINCIPAL IN CHARGE:I TJJ <br /> I PROJECTMANAGER: DH <br /> L C PROJECT ARCHITECT: MS <br /> 00 SILUD�'IO Uri ) - _ - JOB CAPTAIN: GM <br /> O tL <br /> L TYPe — <br /> J 316 I <br /> Sensory - O <br /> Accessible I _ <br /> II L _ L <br /> 18ED Unit STUDIO Unit <br /> 11 BED Unit STUDIO Unit Type-B Type-B <br /> �1Te-B f Typa-B I 318 F 319 - <br /> 1 BED U�, 315 317 478 SF 296 SF <br /> 500 SF 395 SF I r\ <br /> A3.12 _ rrII Sensory <br /> - T J L�' Accessible - -J <br /> r 1.5 <br /> 1BED Unit o 475 SF <br /> 1 - ICE <br /> 437 S ` -ST�',_ ^Typ-I - L o o - - I ABOVE TO BEE2 LAYERSTOF 5/BILGWB ON <br /> ST#1" _ RSIC-1 CLIPS AND CAVITY W/8"BA17 <br /> INSULATION PER ACOUSTICAL REPORT <br /> 23 — —-—-—- A3 -—.—.—. —.—-—-—-—. -—-—-—- I —l—-—-—-—-—-—-—-—- - DRAWING <br /> R12EXT� — P - P P---------P --------- P.—.------ P �- <br /> IV <br /> �/ I ` - 1 1 <br /> 23D <br /> A D.9 A <br /> 7"@EXT F.O. TU SD Floor Plan - Level 3 <br /> 4'-11" 17'-13/4" 9'-91/4" 18'-93/4" 15'-10" 12'-6" 12'-6" 14'-0" 14'-0" 22'-10114" V-51/2"@EXT F.O.STUD <br /> A.3 <br /> 142'-11" <br /> DRAWING <br /> A G a <br /> Floor Plan - Level 3 0 4' B' 16' _ <br /> Scale:1/8"=1'-0" 1 <br /> 1 2 3 4 5 6 <br />