My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3315 BROADWAY HOPEWORKS STATION 2 2026-01-02
>
Address Records
>
BROADWAY
>
3315
>
HOPEWORKS STATION 2
>
3315 BROADWAY HOPEWORKS STATION 2 2026-01-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 10:44:58 AM
Creation date
3/24/2025 11:22:06 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3315
Tenant Name
HOPEWORKS STATION 2
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 3 4 5 6 <br /> Wall Legend General Notes- Residential Floor Plans Keynote Legend <br /> MTL.FRAMED WALL A. EXTERIOR DIMENSIONS ARE TO THE OUTSIDE FACE OF STUDSUNLESS M. CONTRACTOR TO CONFIRM ALL CLEARANCE REQUIREMENTS AS NOTED ON <br /> OTHERWISE NOTED. DETAIL A6.01. Key Value Keynote Text <br /> B. DIMENSIONS AT UNIT DEMISING WALLS ARE TO CENTERLINE OF WALL. N. REFER TO DETAILS ON SHEET A6.01 FOR TYPICAL DOOR CLEARANCES. <br /> STANDARD WALL C. INTERIOR DIMENSIONS ARE TO THE FACE OF STUDS AT FRAME WALLS,AND TO O. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS AT FIRE RATED WALLS, 27 3200.A 7W0-WAY COMMUNICATION SYSTEM WI AUDIBLE AND VISIBLE <br /> CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED. INCLUDING BUT NOT LIMITED TO PIPING,DUCTS,CONDUIT,ETC.,WITH SIGNALS <br /> D. DIMENSIONS LOCATING DOORS,WINDOWS AND RELIGHTS ARE TO NOMINAL FIRESTOPPING PER I.B.C.REQUIREMENTS. <br /> INSULATED OR ACOUSTIC WALL MASONRY OPENING OR TO FINISH OPENING UNLESS OTHERWISE NOTED. P. SEE EXTERIOR ELEVATIONS FOR WINDOW AND LOUVER TYPES AND DETAILS. . <br /> E. SEE WALL TYPES ON SHEET A1.01 FOR TYPICAL WALL CONSTRUCTION Q. SEE ENLARGED PLANS FOR ADDITIONAL DIMENSIONAL AND NOTE <br /> YKEMAN <br /> ASSEMBLIES. INFORMATION. <br /> F. ALL NON-BEARING WALLS ARE FULL HEIGHT TO UNDERSIDE OF FLOOR ABOVE. R. TYPICAL WALLS AT UNIT INTERIORS ARE WALL TYPE WIN 411 UNLESS NOTED <br /> WOOD FRAMED WALL G. APPLY TWO(2)CONTINUOUS SEALANT BEADS BENEATH STUD TRACK AT ALL OTHERWISE.FOR TYPICAL WALLS AT UNIT INTERIORS REFER TO UNIT 201 ON ARCHITECTURE + DESIGN <br /> EXTERIOR STUD WALLS. SHEET A4.22A. <br /> H. CONTCTOR SHALL PROVIDE CONTINUOUS HORIZONTAL BLOCKING AT ALL S. SENSORY ACCESSIBLE UNITS PROVIDED PER UFAS SECTION 4.28.2 AND 4.28.3 <br /> STANDARD WALL WALL MRAOUNTED LAVATORIES,DRINKING FOUNTAINS,CASEWORK,MIRRORS, WITH: <br /> HANDRAILS,ETC.REFER TO ARCHITECTURAL INTERIOR ELEVATIONS AND a. AUDIBLE ALARMS-AUDIBLE EMERGENCY ALARMS,SHALL PRODUCE A <br /> MECHANICAL DRAWINGS. SOUND THAT EXCEEDS THE PREVAILING EQUIVALENT SOUND LEVEL IN THE <br /> INSULATED OR ACOUSTIC WALL I. SEE DETAIL SHEET A6.01 FOR TYPICAL MOUNTING HEIGHTS FOR WALL ROOM OR SPACE BY AT LEAST 15 DECIBELS OR EXCEEDS ANY MAXIMUM <br /> E MOUNTED ACCESSORIES AND EQUIPMENT. SOUND LEVEL WITH A DURATION OF 30 SECONDS BY 5 DECIBELS, E <br /> J. SEE INTERIOR DESIGN DRAWINGS FOR TRANSITION DETAILS AND THRESHOLDS. WHICHEVER IS LOUDER.SOUND LEVELS FOR ALARM SIGNALS SHALL NOT <br /> K. ELECTRICAL PANELS,TRANSFORMERS,BOILERS,AIR HANDLING UNITS,AND EXCEED 120 DECIBELS. • <br /> DUCTWORK WHEN SHOWN,ARE IN <br /> FOR CONTRACTOR CONVENIENCE. b. VISUAL ALARMS-ELECTRICALLY POWERED INTERNALLY ILLUMINATED <br /> SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR SPECIFIC SIZES AND EMERGENCY EXIT SIGNS SHALL FLASH AS A VISUAL EMERGENCY ALARM IN <br /> LOCATIONS. CONJUNCTION WITH AUDIBLE EMERGENCY ALARMS.THE FLASHING <br /> L. SEE MECHANICAL AND ELECTRICAL PLANS FOR CEILING MOUNTED EQUIPMENT. FREQUENCY OF VISUAL ALARM DEVICES SHALL BE LESS THAN 5 HZ.IF SUCH <br /> ALARMS USE ELECTRICITY FROM THE BUILDING AS A POWER SOURCE, <br /> THEN THEY SHALL BE INSTALLED ON THE SAME SYSTEM AS THE AUDIBLE <br /> EMERGENCY ALARMS. <br /> • <br /> A G <br /> 142'-11" <br /> 6167 REGISTERED <br /> 1"@ EXT F.O.STU ARCHITECT <br /> 5'-6" 16'-01/2" 18'-11/4" 10'-01/2" 12'-81/4" 15'-10" 15'-10" 15'-10" 12'-6" 20'-61/2" 1'-51/2"@EXT F.O.STUD <br /> TI 0 Y JAMES EWETT <br /> ❑ HATCHED AREA INDICATES ❑ S AT OF WASH GTON <br /> r ti CEILING ABOVE TO BE 2 <br /> y pW LAYERS OF 5/8"GWB ON p pyy p p pyy <br /> O 2 RSIC-1 CLIPS AND CAVITY 2 1 O <br /> A3.12 W/8"BAIT INSULATION 5 A3.11 A3.11 w <br /> D 1 A4.51 CS 1 w PROJECT IDENTIFICATION: D <br /> 4.24B CS 4 24 <br /> +- - - -J J - - _ - --__ -_-_-_ ___-_ __-_ ____-_ - - - - _- -_ - - - 6 HOSTATION <br /> TP/ETWORKS <br /> 2 BED Unit 1BED Unit STAIR#2- STUDIG Unit iBED Unit iBED U. O iBED Unit STUDIO Unit S I/-1 I I O N <br /> Type-B Type-13 STN2 Type-B Type-B Type-B Ty B Type-B <br /> 408 406 _ J 40s 404 L _ 03 �� 402 <br /> 522 SF 349 SF _ �L 399 SF 373 SF 372 SF 391/SF 71 1 r09 SF FOR <br /> - - HOPEWORKS & <br /> . r Ll I HOUSING HOPE <br /> --- � J o o I L o o I I L 2 BED Unit <br /> O o O Type-B <br /> I I a-41/ - oo 401 AT <br /> Tw42n6s, 00 L] — J ¢] s3zsF 3315 BROADWAY, <br /> \48 SF — <br /> r EVERETT, WA <br /> 0 ) r (WH) Oo <br /> CONFORMED SET <br /> 14'-0"@EOS 273200.A - _T -- <br /> 1®I J <br /> 1q)f <br /> o ® 05/15/2018 <br /> ���// UCUND ROOF GARDEN <br /> EL�ye•i ELEC. I 424 / �'£Q EQ EQ EQ EQ 423 <br /> /\ 425 88 SF L N.B.: This drawing is: <br /> C 210 / \ 42 SF CL CL CL REFER TO LANDSCAPE FD - 1.Copyright 2017 Dykeman,Inc. C <br /> A3. c9 v /p% - Z FOR PAVERS 8 LAYOUT A3.10 2.The Architect's Instrument of Professional Service. <br /> Ja 0 3.For use on this project only.Obtain Architect's <br /> O written permission for any other use or reproduction. <br /> a <br /> /25' 7112" 1' 51/2" <br /> Ii rL�� I I I <br /> vPROJECT <br /> STUDIO Unit— J` - — - n <br /> Type-B <br /> 408 — J r O <br /> 314 SF 5'-7"FROM COLUM CTR TO FOS OPEN BELOW I <br /> 2016-025 <br /> COURTYARD L2 5'-7"FROM COLUM CTR O FOSa MARK DATE DESCRIPTION <br /> N.B.: A STUDIO Unit _ J L J REFER TO LANDSCAPE O l�' 11/i6/2017 Pricing Set <br /> Type-B FOR PAVERS&LAVOUT 12/08/2017 Permit Set <br /> 410 r — J — J O Z 1BED Unit <br /> 02/08/2018 Bid Set <br /> 309 SFL JI �� C fit- O T B ADD#1 02/22/2018 Addendum#1 <br /> -—- -—- -— -—-—-—-—-—-—-— EQ ¢ 421 BPR 03/12/2018 BLDG Permit Revision <br /> a — —.�_—.—_— EQ A - 405 SF <br /> CS 05/14/2018 Conformed Set <br /> —L <br /> -� -STUDIO Unit JL — J L — J ¢ ------ - - (Dc' <br /> Type B EO O o r — <br /> 411 L — J L — J L k�STpD10 Unit <br /> 310 SF _ 1 F B <br /> a — <br /> 0 <br /> Oo0 I®I (WH) — <br /> _ STUDIO Unit r O r I W a <br /> L — <br /> B i Type-B L — J L — J v (WH) O o _ 42 r — J 2 Unit SOLAR PANEL B <br /> 360 SF _,L — J<YLe-B J ABOVE(TYP) •• <br /> 419 <br /> CS J 0 r O O 671 SF PRINCIPAL IN CHARGE:I TJJ <br /> — . PROJECT MANAGER: DH <br /> r o` 0 �Ir 71 PROJECT ARCHITECT:I MS <br /> Imo_ (WH) 00 o0 L —711 <br /> - JOB CAPTAIN: IGM <br /> r- 1 I , J <br /> L_ JI _- `cJ _J LJ - <br /> Ii1 F F7 I JI <br /> _ I i <br /> L JL <br /> 7 - <br /> 1 I <br /> I A 7 BED Unit STUDIO Unit <br /> F1 BED Unit <br /> 2 BED Unit - <br /> e <br /> TYP eA <br /> Type-B <br /> r <br /> O <br /> 7 <br /> T -A <br /> 418 <br /> 0 <br /> - L L TYPe'g 416 I 417 296 SF <br /> 478 SIF <br /> A.12 1 BED Unit o O 509 SF 799 SF <br /> 1.5 — _ — TyIF <br /> p-B <br /> 1 _ 1BED Unit _ o o _ 445 SF _ L r _ _ _ _ _ _ — _ _ _ _ 1 <br /> 437 SF Y l w <br /> 0.5 - - - - - - - 1 - - - - - - - - - - - - - - - - � — <br /> w <br /> _ O e•AWING TITLE: <br /> R12� .— .—._T —.—.—.—.—.---.—.—.A4.50 .---.--P .—.—.---.--p -—-—-—-—-—-—-—-—- <br /> ----_—_—. P.— P—_�_------------4- - a <br /> 4.24C <br /> 4.24D <br /> 7"@EXT F.O.STUD Floor Plan - Level 4 <br /> 1 4'-11" 17'-13/4" 28'-7" 15' 10" 25'-0" 14'-0" 14'-0" 22'-10114" V-51/2"@EXT F.O.STUD <br /> A.3 <br /> 142'-11" <br /> DRAWING <br /> A <br /> G a <br /> �0=? <br /> an-Level 4 N 4' B' 16' <br /> iz <br /> Scale:1/8"=1'-0" 2 <br /> 1 2 3 4 5 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.