Lighting, Motor and Electrical Requirements List, pg 1 of 13 <br /> • <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2024 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> Project: <br /> Little Pandas Play Cafe-2021 WSEC <br /> 210 SW Everett Mall Way <br /> Everett,WA 98204 <br /> Date:2024-06-27 <br /> Applies Code Section Component Compliance Information Required In Permit Location in Building Department <br /> Documentation Documents Notes <br /> LIGHTING SCOPE <br /> C 10 3.1 Construction For a shell&core or tenant space(first build- <br /> documents-General out)project,indicate if there is no lighting <br /> scope included in the project. <br /> NO C103.1 Construction For an alteration project,indicate if there is <br /> documents-General no lighting scope included in the project. <br /> NA C405.1 Lighting in sleeping Indicate general compliance path for <br /> units permanently installed luminaires in sleeping <br /> units-vacancy controls&luminaire efficacy; <br /> or lighting power allowance. <br /> INTERIOR LIGHTING CONTROLS <br /> YES C405.2 Interior lighting For all interior lighting systems,indicate <br /> controls,general lighting control method(general lighting <br /> controls requirements or luminaire level <br /> lighting controls)on plans for all spaces and <br /> lighting zone(s)served;indicate exceptions <br /> applied to eligible spaces and light <br /> YES C405.2.3 Manual controls Indicate on plans the method of manual <br /> lighting control,location of manual control <br /> device and the area or specific application it <br /> serves. <br /> NA C405.2.4 Manual interior light .For general lighting not controlled by <br /> C405.2.4.1 reduction controls occupancy sensors,indicate on plans which <br /> i method of manual 50%lighting load <br /> ' reduction is provided,or indicate applicable <br /> exception. <br /> NA C405.2.1 Method of automatic ',Indicate on plans the method of automatic <br /> C405.2.2 shut-off control shut-off control during unoccupied periods <br /> (occupancy sensor or time switch)for all <br /> lighting zones. <br /> NA C405.2.1 Occupant sensor Indicate on plans all luminaires that are <br /> controls controlled by occupant sensor controls; <br /> indicate controls are configured to turn <br /> luminaires 100%off when the space is <br /> unoccupied <br /> NA C405.2.1 Occupant sensor Indicate if occupant sensor controls are <br /> C405.2.1.1 controls configured to be manual on or automatic on to <br /> not more than 50%power;indicate spaces <br /> eligible for exception that allows automatic on <br /> to 100%power. <br /> NA C405.2.1.2 Occupant sensor Indicate each aisleway within a warehouse or <br /> controls-warehouse library stack space designated as a separate <br /> storage areas& zone that is independently controlled <br /> library stacks <br /> Page 4ff:S— lV <br />