Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 2 of 13 <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2024 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA Indicate occupant sensors are configured to <br /> automatically reduce lighting power by>_50% <br /> when the zone is unoccupied for over 20 <br /> minutes;indicate controls are configured to <br /> automatically restore lighting to full power <br /> when the zone or space is occupie <br /> NA C405.2.1.2 Occupant sensor Indicate method of automatic 100%shut-off <br /> controls-warehouse (occupancy sensor or time switch) <br /> storage areas& <br /> library stacks <br /> NA C405.2.1.3 Occupant sensor For open plan office areas larger than 300 sf, <br /> controls-open plan indicate all general lighting control zones are <br /> office areas <600 sf <br /> NA C405.2.1.3 Occupant sensor Indicate all general lighting control zones are <br /> controls-open plan provided with vacancy controls that are <br /> office areas configured to reduce lighting power by not <br /> less than 80%when the zone is unoccupied <br /> I j <br /> and turn luminaires 100%off when the <br /> control zone is unoccupied;indicate unoccup <br /> NA C405.2.1.4 Occupant sensor Indicate stairway lighting is provided with <br /> controls-enclosed occupancy sensor controls that reduce lighting <br /> fire-rated stairwells power by not less than 50%when the stairway <br /> in unoccupied and restore lighting to 100% <br /> when it is occupied. <br /> NA C405.2.1.5 Occupant sensor Indicate corridor lighting is provided with <br /> controls-corridors occupancy sensor controls that reduce lighting <br /> power by not less than 50%when the corridor <br /> is unoccupied. <br /> NA C405.2.2.1 Automatic time i Indicate spaces on plans where time switch <br /> switch controls controls are configured to turn luminaires <br /> 100%off during unoccupied hours <br /> NO Indicate spaces on plans where time switch <br /> controls are configured to turn on lighting to <br /> full power versus 50%power <br /> NA Indicate locations of override switches on <br /> plans and the lighting zone(s)served;indicate <br /> that the area(s)served by each override switch <br /> does not exceed 5,000 sf. <br /> NA C405.2.5.2 Daylight zones- Indicate primary and secondary sidelit <br /> C405.2.5.4 Sidelit zones daylight zone floor areas on plans <br /> NA For small vertical fenestration assemblies <br /> (rough opening less than 10%of primary <br /> daylight zone floor area)where daylight <br /> responsive controls are not required,provide <br /> fenestration area to daylight zone floor area <br /> calculation(s). <br /> NA Indicate toplit daylight zone floor areas on <br /> plans. <br /> NA C405.2.5 Daylight responsive Indicate on plans all lighting zone(s)served by <br /> C405.2.5.1 controls daylight responsive controls;indicate that the <br /> area served by each control device does not <br /> exceed 2,500 SF <br /> Page-2/43 5I1 <br />