Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 7 of 13 <br /> • <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2024 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA Identify spaces eligible for lighting power <br /> exemption on plans and in WSEC interior <br /> lighting compliance reports;indicate the <br /> exception applied <br /> NA Identify lighting equipment eligible for <br /> lighting power exemption in fixture schedule <br /> and in WSEC interior lighting compliance <br /> reports;indicate the exception applied. <br /> C405.1.1 Lighting in dwelling Include all permanently installed luminaires in <br /> units dwelling units in interior lighting fixture <br /> schedule;include luminaire lighting power <br /> and efficacy(lumens) <br /> Include all permanently installed luminaires in <br /> sleeping units in interior lighting fixture <br /> schedule;include luminaire lighting power or <br /> efficacy(lumens)depending on compliance <br /> path taken per C405.1 <br /> NA 1 j For all permenantly installed luminaires, <br /> indicate in interior lighting fixture schedule <br /> that rated lamp efficacy is>_65 lumens/watt <br /> or luminaire efficacy is>_45 lumens/watt. <br /> NO C405.4.2 Interior lighting Indicate which interior LPA method is <br /> power allowance applied to the entire building(Building Area <br /> (LPA) Method or Space-by-Space Method);indicate <br /> LPA applied is Space-by-Space Method for <br /> partial building projects and for buildings <br /> with unfinished spaces. <br /> INTERIOR LIGHTING POWER CALCULATION-INDICATE COMPLIANCE PATH TAKEN <br /> NA C405.4.2.I Building Area Demonstrate that total proposed interior <br /> Method lighting wattage per building does not exceed <br /> the sum of the maximum allowed wattages for <br /> all building area types;identify locations of <br /> building areas on plans;provide WSEC <br /> interior lighting compliance reports. <br /> YES C405.4.2.2 j Space-By-Space Demonstrate that total proposed interior <br /> Method lighting wattage does not exceed the <br /> maximum allowed wattage;identify locations <br /> of space types on plans,including additional <br /> allowance retail display areas and areas with <br /> display,highlight and decorative lightin <br /> INTERIOR LIGHTING POWER&EFFICACY-ADDITIONAL ENERGY EFFICIENCY MEASURES <br /> NA C406.2.3.1 Reduced interior 'To comply with the reduced interior LPD <br /> C406.2.3.2 lighting power additional energy efficiency measure, <br /> density(LPD) demonstrate that total proposed interior LPD <br /> wattage is 10%or 20%lower than the total <br /> interior LPA wattage for the area the reduced <br /> lighting power measure is being applied to <br /> Page W4- I() <br />