Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 6 of 13 <br /> • <br /> 2021 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2024 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> For outdoor parkins area(not parking garage) <br /> luminaires that are mounted 5 24 feet high <br /> and arc rated at 40 watts,indicate that <br /> controls are configured to turn this lighting <br /> off when daylight is present;in addition, <br /> I � indicate controls arc config <br /> For exterior lighting other than building <br /> facade,landscape and outdoor parking area <br /> lighting,indicate controls are configured to <br /> reduce lighting power by at least 50%from <br /> 12am-6am,or 1 hour after closing to l hour <br /> before opening,or when no activity i <br /> C405.2.It) Parking garage Indicate all interior parking garage lighting <br /> lighting control fixtures are provided with time switch <br /> controls(per C405 2.2.1)or occupancy sensor <br /> controls(per C405.2.1.1);indicate controls <br /> are configured to reduce lighting power by at <br /> least 30%when no activity is det <br /> C405.2.10 Parking garage For parking garage lighting fixtures located <br /> lighting control- within 20 feet of perimeter wall openings. <br /> Perimeter lighting indicate on plans that daylight sensing controls <br /> zones are configured to reduce lighting power by at <br /> least 50%.or exception applied <br /> t405.2.10 Parking garage For lighting fixtures at sehicle entrances& <br /> lighting control-Eye exits,indicate on plans that daylight sensing <br /> adaptation lighting controls:!r _.! Lured to reduce lighting <br /> power 1s- .- from sunrise to sunset. <br /> NA C405.3 Lighting for plant For permanently installed lighting fixtures <br /> growth and used specifically for plant growth and <br /> maintenance ' maintenance,indicate that the photosynthetic <br /> photon efficacy measured at the lamp or <br /> luminaire is>_ 1.7 1/,1/2mo1/J in greenhouses <br /> and>1.9 Yzt/zmol/J in all other indoo <br /> C405.5.4 Exterior gas-fired Indicate ignition system is a mc!hod other <br /> lighting appliances then continuously burning pilot light. <br /> INTERIOR&EXTERIOR LIGHTING CONTROL CIRCUITS <br /> NA C405.2.7 Area controls- Indicate location(s)of lighting master control <br /> Master control switch(es)intended to control multiple <br /> switches independent switches;a circuit breaker may <br /> not be used as a lighting master control switch <br /> NA Verify the maximum power controlled by any <br /> single lighting control switch or automatic <br /> control device is no more than a 20 amp <br /> circuit loaded to?80%. <br /> INTERIOR LIGHTING POWER&EFFICACY <br /> NA C405.4.1 Total connected Include all luminaires in interior lighting <br /> interior lighting fixture schedule;indicate fixture types,lamps, <br /> power ballasts and rated watts per fixture;include <br /> rated wattage of lamps for luminaires with <br /> lamps connected directly to building power; <br /> include wattage limit of tran <br /> Page 4 43- CI I' <br />