My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3617 UPLAND AVE Geotech Report 2025-03-28
>
Address Records
>
UPLAND AVE
>
3617
>
Geotech Report
>
3617 UPLAND AVE Geotech Report 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 8:06:09 AM
Creation date
3/28/2025 8:04:22 AM
Metadata
Fields
Template:
Address Document
Street Name
UPLAND AVE
Street Number
3617
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G099T 1.888.251.5276 <br /> Bellingham I Arlington I Oak Harbor <br /> www.geotest-i nc.com <br /> February 10, 2021 <br /> Proposal No. 21-17OG <br /> ASPI, LLC <br /> 5205 S 2nd Avenue, Suite A <br /> Everett, WA 98203 <br /> Attention: Mr. Andrew Lofstedt, AICP <br /> Re: Proposal—Geotechnical Engineering Services <br /> Tucker Short Plat <br /> 3617 Upland Avenue <br /> Everett, WA 98203 <br /> Dear Mr. Lofstedt: <br /> As requested, GeoTest Services, Inc. (GeoTest) is pleased to submit this geotechnical engineering <br /> proposal for the property referenced above. Our proposed scope of work and associated fees <br /> are presented herein for your review and approval. <br /> PROJECT DESCRIPTION <br /> GeoTest understands that a 19,628 square foot property will be short platted,with the end result <br /> being two separate properties. The project site contains an existing single-family residence with <br /> entry in to the property being along Upland Avenue. GeoTest understands that the existing <br /> residence will remain, but will be renovated to include additional living space and a new detached <br /> garage. A new single-family residence will be constructed to the west of the existing residence <br /> and it is generally expected that the new property line will extend between the two structures. <br /> Geyer Lane exists along the western property boundary and Upland Avenue exists along the <br /> southern property boundary. The property has a moderate slope to the north of the house. The <br /> height and inclination of the slope suggests that geologically hazardous areas are not likely <br /> present on this property. It is expected, however, that some site grading will be needed to <br /> establish a buildable lot adjacent to the existing house. Finally, it is expected that any infiltration <br /> or stormwater detention facilities, if needed, would be constructed to the north of the proposed <br /> houses. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.