Laserfiche WebLink
a <br /> Panel D(EXIST)42 kAIC PANEL SCHEDULE jPR.1E.1 PSKC-EVERETT <br /> DETAIL NOTES: <br /> 120/208V,3Ph,4W. 1 ODA Bus M.L.O. SURFACE MOUNTED 10-May-21 Uj <br /> Ckt. Description/ Load Load C.B. C.B. C.B. C.B. Load Load Description/ Ckt. 6 a- <br /> No. Location (VAD Type Amp Pole Phase Amp Pole VA Type Location No. D CUTOVER(E)SPLIT SYSTEM AIR CONDITION IN(E)SERVER ROOM TO PANEL D z <br /> AS SHOWN.PROVIDE(N)CIRCUIT BREAKER TO MATCH EXISTING TYPE AND <br /> 1 UPS 1,200 R 30 2 A 30 2 1,400 G SPLIT SYSTEM PJC(EXIST) 2 < STYLE.PROVIDE CONDUIT AND#10 COPPER WIRE AS NECESSARY. U <br /> 3 - 1,200 R - - IS - - 1,400 G (RECONNECT EXIST FEEDERS) 4 to�. <br /> 5 UPS 1,200 R 30 2 C 30 2 SPARE 6 Q7!E <br /> 7 - 1,200 R - - A - - - a 15 2 <br /> 9 GENERAL REC. 360 R 20 1 B 20 1 SPARE 10 <br /> 11 GENERAL REC. 360 R 20 1 C 20 1 SPARE 12 <br /> 13 SERVER REC. 1,500 R 20 1 A 20 1 SPARE 14 <br /> 15 SERVER REC. 1,500 R 20 1 B 20 1 SPARE 16 <br /> 17 SERVER REC. 1,500 R 20 1 C 20 1 SPARE 18 <br /> 19 SERVER LTG 256 L 20 1 A 20 1 SPARE 20 <br /> 21 SPARE 20 1 B 20 1 SPARE 22 <br /> 23 SPARE 20 1 C 20 1 SPARE 24 <br /> 25 SPARE 20 1 A 20 1 SPARE 26 <br /> 27 SPARE 20 1 B SPACE 28 <br /> 29 SPARE 20 1 C SPACE 30 2727 Oakes Ave. <br /> 31 SPARE 20 1 A SPACE 32 Suite 100 <br /> 33 SPARE 20 1 B SPACE 34 O Everett,WA 98201 <br /> 35 SPARE 20 1 C SPACE 36 <br /> 37 SPD 30 3 A SPACE 38 W REVISIONS <br /> y <br /> 39 - - - B SPACE 40 t0 X <br /> 41 - - - C SPACE 42 y In MO I,-'- <br /> �+ <br /> 00 <br /> Total Connected Load: Ph A 5,556 VA 46 A <br /> Total Connected Load: Ph B 4,460 VA 37 A O <br /> Total Connected Load: Ph C 3,060 VA 26 A <br /> Total Connected Load: 13.1 KVA Total Demand Load: 13.1 KVA U) D C <br /> 36.3 AMPS 36.5 AMPS r o <br /> Connected Subfed Total Demand Demand <br /> G General(Non-Continuous) Loads 2 800 Loads(S) Loads 2 80 Factor 0 M <br /> Load 2 80 A. q <br /> L Lighting 256 256 125% 320 M 1r7 r: d WAS''/tiOC� <br /> R Receptacles-to 10 KVA 10,020 10,000 100% 10,000 Accessories: <br /> ver 10 KVA 20 50% 10 O\ y g n <br /> K Kitchen 0 0 100% 0 W '"'a� m <br /> H Heating 0 0 100% 0 <br /> M Motors 0 0 100% 0 <br /> LM Largest <br /> WH Water Heatterr 0 0 125% 0 _. , e�IONAL ENC� <br /> C Continuous General Load 0 0 125% 0 <br /> 13,076 VA 0 VA 13,076 VA 13,130 VA <br /> NOTES: <br /> BOLD TYPE INDICATES LOAD NEW TO THIS PANEL <br /> Panel H(EXIST)42kAIC PANEL SCHEDULE JPR.el PSKC-EVERETT <br /> 120/208V,3Ph,4W. 100A Bus M.L.O. SURFACE MOUNTED 10-May-21 <br /> Ckt. Description/ Load Load C.B. C.B. C-B. C.B. Load Load Description/ Ckt. <br /> No Location A Type Amp Pole Phase Amp Pole A Type Location No <br /> 1 FACP 500 G 20 1 A 20 1 1,656 M EF-3 2 <br /> 3 ELECTRIC WALL HEATER 1,000 H 2C 1 B 20 1 1,656 M EF-4 4 <br /> 5 MAIN TTB REC. 360 R 20 1 C 20 1 135 M EF-5 6 <br /> 7 GENERAL REC. 900 R 20 1 A 20 1 250 WH GAS WATER HEATER&CIRC PUMP 8 <br /> 9 ELECTRIC WALL HEATER 1,000 H 20 1 B 20 1 100 G CO CONTROLLER 10 <br /> 11 SPARE 20 1 C 20 1 450 L EXTERIOR NORTH PARKING LIGHTING 13 ELEVATOR PIT LTG&REC. 308 R 20 1 A 20 1 400 G GENERATOR BATERY CHARGER 14 W <br /> 15 ELEVATOR MACHINE ROOM REC.&LTG 244 R 20 1 B 20 1 600 G GENERATOR BLOCK HEATER 16 <br /> 17 PARKING GARAGE LTG 864 L 20 1 C 20 1 SPARE <br /> 19 ELEC./RISER ROOM LTG 192 L 20 1 A 20 1 SPARE 20 <br /> 21 GENERAL REC. 360 R 20 1 B 20 1 SPARE 22 LLI <br /> 23 STAIR LTG 256 L 20 1 C 20 1 SPARE 24 <br /> 25 EXTERIOR SITE LTG 500 L 20 1 A 20 1 SPARE 26 <br /> 27 EXTERIOR LIGHTING 332 L 20 1 B 20 1 SPARE 28 > <br /> 29 EXTERIOR BUILDING LIGHTING 156 L 20 1 C 20 1 SPARE 30 W E]:�Q <br /> 31 SPACE A SPACE 32 <br /> 33 SPACE B SPACE 34 L I� <br /> 35 SPACE C SPACE 36 W <br /> 37 SPACE A SPACE 38 \ / -Z Q <br /> 39 SPACE B SPACE 40 �/ � � <br /> 41 SPACE C SPACE 42 <br /> Total Connected Load: Ph A 4,706 VA 39 A <br /> Total Connected Load- Ph B 5,292 VA 44 A <br /> Total Connected Load_ Ph C 2,221 VA 19 A <br /> Total Connected Load: 122 KVA Total Demand Load: 130 KVA <br /> 33-9 AMPS 36.0 AMPS <br /> JOB,na. 20056.A <br /> Connected Subled Total Demand Demand -NBr LRD <br /> Loads Loads(S) Loads Factor Load <br /> G General(Non-Cortinuous) 1 600 1,600 100% 1,600 <br /> L Lighting 2,750 2,750 125% 3,438 caECKED BY BA <br /> R Receptacles-to 10 KVA 2,172 2,172 100% Z172 Accessories <br /> over 10 KVA 0 50% 0 <br /> K IOtchen 0 0 100% 0 <br /> H Heating 2,000 2,000 100% 2.000 <br /> M Motors 3,447 3,447 100% 3,447 <br /> LM Largest Motor 0 0 125% 0 5/11/2021 <br /> WH Water Heater 250 250 125% 313 <br /> C Continuous General Load 0 0 125% 0 <br /> 12,219 VA 0 VA 12219 VA 12969 VA <br /> NOTES PANEL <br /> BOLD TYPE INDICATES NEW ITEM SCHEDULES <br /> E3 , 0 <br />