My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
400 RIVERSIDE RD SEPA 016 - 039 - RIVERSIDE BUSINESS PARK Geotech Report 2025-04-14
>
Address Records
>
RIVERSIDE RD
>
400
>
SEPA 016 - 039 - RIVERSIDE BUSINESS PARK
>
Geotech Report
>
400 RIVERSIDE RD SEPA 016 - 039 - RIVERSIDE BUSINESS PARK Geotech Report 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 7:58:17 AM
Creation date
4/4/2025 11:43:01 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
400
Tenant Name
SEPA 016 - 039 - RIVERSIDE BUSINESS PARK
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 8, 2016 <br /> Project No. T-7388-1 <br /> A map titled Geologic Map of the Marysville Quadrangle, Snohomish County, Washington by J.P. Minard, dated <br /> 1957, shows the site soils mapped as Qyal, Younger alluvium. This map unit is consistent with the native soils <br /> found beneath the fills in our field observations. <br /> ' The preceding discussion is intended to be a brief review of the soil conditions observed at the site. More <br /> detailed descriptions of the subsurface conditions at the site are summarized on the CPT Logs attached in <br /> Appendix A. Logs of test borings advanced at the site by others are provided in Appendix B. The approximate <br /> ' locations of the CPTs,and test borings by others are shown on Figure 2. <br /> ' 3.3 Groundwater <br /> Dissipation tests at CPT-1 and CPT-5 determined hydrostatic groundwater levels of 10.7 to 4.8 feet below <br /> existing grades at those locations. We expect that the groundwater levels noted during our investigation are near <br /> their seasonal high. Groundwater levels would be expected to be lower during late summer to early fall (July <br /> through September). <br /> 4.0 SEISMIC <br /> Liquefaction is a phenomenon where there is a reduction or complete loss of soil strength due to an increase in <br /> water pressure induced by vibrations. Liquefaction mainly affects geologically recent deposits of fine-grained <br /> ' sands underlying the groundwater table. Soils of this nature derive their strength from intergranular friction. The <br /> generated water pressure or pore pressure essentially separates the soil grains and eliminates this intergranular <br /> friction; thus, eliminating the soil's strength. <br /> ' We completed a liquefaction analysis using the computer program Liquefy 5 published by CivilTech <br /> Corporation. Liquefy 5 incorporates CPT sounding data into analysis. For the analysis, site-specific <br /> determinations of the soils' shear wave velocity and de-aggregated earthquake magnitude were obtained from <br /> USGS online map-based calculators. The analysis was completed using a peak ground acceleration of 0.36g, and <br /> an earthquake of Magnitude 6.8, which represents ground shaking that could be expected for an earthquake <br /> having a 10 percent probability of exceedance in a 50-year period (return period of once per 500 years). The <br /> results of the liquefaction analysis are attached in Appendix C. <br /> ' The results of our analysis indicate soil liquefaction could occur during the design earthquake event. Impacts to <br /> site structures and infrastructure should liquefaction occur would be in the form of subsidence with total <br /> ' settlements in the amount of 1 '/2 to 3 inches and differential movement in the range of to 1 '/2 inches expected. <br /> This amount of settlement would cause cosmetic cracking of the structure and pavements, but would not <br /> structurally impair their use, in our opinion. Some utility connections may also be impacted. <br /> The northeast corner of Building A will be located approximately 100 feet from the Snohomish River. The <br /> building's proximity to the Snohomish River necessitated a lateral spreading analysis in order to evaluate <br /> ' potential impacts to the building from liquefaction-induced lateral spreading ground movements. The analysis <br /> yielded a potential lateral spreading soil displacement of 1 '/2 to 2 inches at the eastern margin of Building A. As <br /> with the vertical liquefaction movements discussed above, these lateral movements would likely result in <br /> cosmetic impacts to the building without structural impairment. <br /> ' Page No. 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.