Laserfiche WebLink
r <br />DOOR <br />NO. <br />ROOM NAME <br />112 <br />CHECK-INICHECK-OUT <br />m <br />111 <br />CENTRALIZED CHECK -IN <br />113 <br />ISECURITY <br />DOOR <br />TYPE LEGEND <br />F FLUSH <br />(HINGED) <br />DOOR SCHEDULE <br />FRAME I HARDWARE <br />CARD <br />WXH TYPE MATERIAL FINISH TYPE MATERIAL FINISH CLOSER I READER COMMENTS <br />I DOOR HARDWARE LOCATIONS <br />AT DOORS WITH LEVERS OR <br />KNOBS, AND SIMILAR <br />OPERABLE OPENING <br />HARDWARE: <br />LOCATE OPENING <br />HARDWARE HERE <br />-------------- <br />1 I_I <br />I I <br />I I <br />I Y I <br />I I <br />I � I <br />I I <br />I � <br />I � <br />I <br />DOOR, HARDWARE, & WINDOW NOTES <br />1. PRIOR TO FABRICATION, FIELD VERIFY ALL DIMENSIONS. <br />2. REFER TO PROJECT MANUAL AND DOOR SCHEDULE FOR HARDWARE SETS. <br />3. SMOKE RATED DOORS SHALL NOT BE UNDERCUT IN EXCESS OF THE CLEARANCE PERMITTED IN ACCORDANCE <br />WITH NFPA 80. <br />4. ALL DOOR TYPES ARE SHOWN AS SINGLE PANEL, WHETHER SINGLE OR DOUBLE. SEE PLANS FOR ACTUAL <br />CONFIGURATION AND SWING OF DOORS, <br />5. ALL STILE SIZES, RAIL SIZES, LITE SIZES, AND LITE DETAILS SHALL BE PER STEEL DOOR INSTITUTE (SDI) <br />STANDARDS,UNO. <br />6. AT STOREFRONT DOORS, ALL STILE SIZES, RAIL SIZES, AND RAIL LOCATIONS SHALL BE PER THE <br />MANUFACTURER'S STANDARD MEDIUM -STILE DOOR, UNO. <br />7. ALL GLAZING IN DOOR LITES AND SIDE LITES SHALL BE 1/4' TEMPERED GLASS AND SHALL BE WIRE -FREE FIRE <br />GLASS WHERE DOOR IS REQUIRED TO BE FIRE -RATED. <br />8. WHERE A DOOR IS LOCATED IN AN ACCOUSTICALLY RATED WALL, PROVIDE ACOUSTICAL INSULATION IN DOOR <br />FRAME ON ALL SIDES. <br />FRAME TYPE LEGEND <br />OPNG SIZE <br />PER OPNG <br />SCHEDULE <br />A DOOR ONLY <br />FRAME PROFILES <br />HARDWARE SET #1 @ ALL NEW DOORS <br />-CARD READER <br />-CLOSER <br />-WALL STOP <br />-KICK PLATE <br />-ELECTRIC STRIKE <br />U w <br />41/2" TO 6112" FOR NON -WRAP- <br />AROUND FRAME AT CMU WALLS <br />Pi <br />2' <br />F3 C1021.06 HM-FRAME CONFIGURATION <br />AINGIHEADER AS APPROPRIATE TO <br />VING <br />INTERIOR PARTITION PER PLANS - <br />CONSTRUCTION, CONFIGURATION, AND <br />WIDTH MAY VARY <br />UPS <br />ANCHORS PER FRAME SUPPLIER <br />ACOUSTICAL INSULATION IN FRAME <br />WHERE PARTITION HAS ACOUSTICAL <br />INSULATION <br />WRAP -AROUND HOLLOW -METAL FRAME, <br />FIRE -LABELED AT FIRE -RATED <br />OPENINGS, FOR TYPICAL FRAME <br />DIMENSIONS, SEE DETAIL THIS SHEET. <br />DOOR (LEAF) - CONSTRUCTION AND <br />CONFIGURATION MAY VARY <br />C3 C1021.07 HM-FRAME SWING DOOR <br />w 3„ ,1,-0„ <br />- - FASTEN CLIP ANGLE TO <br />BRACE WITH (2) #10 SHEET - <br />METAL SCREWS <br />UNDERSIDE OF EXISTING STRUCTURE ABOVE <br />20 GA. MINIMUM, 2112'MINIMUM <br />STEEL STUD OR TRACK (BRACE) 20 GA. MIN. METAL CLIP -ANGLE. <br />AT 4'-0" OC MAXIMUM - SIZE AS NECESSARY FOR <br />ALTERNATE DIRECTION OF EACH SECURE ATTACHMENT TO <br />BRACE WHERE POSSIBLE STRUCTUREIDECKING ABOVE, <br />FASTEN SIMILAR TO DETAIL FOR <br />PARTITION ATTACHMENT TO <br />STRUCTURE/DECKING ABOVE <br />3" X 3" X 3" X 20 GA. MIN. METAL <br />CLIP -ANGLE - FASTEN TO BRACE <br />AND TO RUNNER/TRACK WITH (2) <br /># 10 SHEET -METAL SCREWS <br />TOP RUNNER/TRACK (SLOTTED <br />OR NESTED OR DEEP -LEG AS <br />NECESSARY TO ACCOMODATE <br />3/4" DEFLECTION) - INSTALL SNUG <br />AGAINST CEILING GRID <br />I <br />STUDS CUT TO ACCOMODATE 3/4" <br />DEFLECTION <br />FRAMED PARTITION PER FLOOR <br />a <br />PLANS - CONSTRUCTION MAY VARY <br />PARTITION TOP DETAIL- BRACED 6" ABOVE CEILING <br />1 112" = l'-0" <br />SUPPORT CEILING METAL STUDS/JOISTS AND <br />TRACKS COMPLYING WITH ASTM C-1007-11a. <br />AND <br />O INSTALL AND FINISH GYPSUM BOARD PER ASTM <br />STANDARD 1-840-11 AND GA-216-13. <br />OR <br />SUPPORT CEILING ON GRID -TYPE SUSPENSION <br />SYSTEM COMPLYING WITH ASTM C-754-11 AND <br />GA-216-13. <br />AND <br />INSTALL AND FINISH GYPSUM BOARD PER ASTM <br />STANDARD C-840-11 AND G1216.13. <br />OR <br />SUPPORT CEILING ON SUSPENSION SYSTEM (WIRES, <br />HAT -CHANNELS AND C-CHANNELS) COMPLYING WITH <br />ASTM C-754-11 AND GA-216.13. <br />INSTALL AND FINISH GYPSUM BOARD PER ASTM <br />STANDARD C4W0.11 AND GA-216.13. <br />C3030.18 CONSTRUCTION OF GYPSUM BOARD CEILINGS <br />3„ = ".0.. <br />'REFER TO ADJACENT WOOD ENTRIES <br />FOR PROFILE AND INSTALLATION. <br />n DETAIL 6a WOOD TRIM SOFFIT <br />EXISTING <br />SOFFIT <br />Ve <br />WALL TYPE <br />SCHEDULE <br />TYPE <br />STUD SIZE <br />THICKNESS <br />FIRE <br />RATING <br />HEAD <br />CONDITION <br />INSULATION <br />TYPE <br />318' <br />A7 <br />3518" <br />47/8" <br />NR <br />FULL HEIGHT <br />NONE <br />A4 <br />3518" <br />47/8" <br />NR <br />FULL HEIGHT <br />ACOUSTICAL BATT <br />G2 <br />2-1/2" <br />a m' <br />NR <br />FULL HEIGHT <br />NONE <br />rA <br />2-1/2" <br />31/8' <br />NR <br />FULL HEIGHT <br />ACOUSTICAL BATT <br />UNDERSIDE OF STRUCTURE ABOVE <br />35/8"MTL TRACK <br />CEILING PER RCP <br />5l8' TYPE "X" GWB BOTH SIDES, EXTEND TO <br />STRUCTURE ABOVE. <br />ACOUSTICAL BATT INSULATION PER WALL TYPE <br />3-5/8" MTL STUD <br />35/8" MTL TRACK <br />SEALANT 8 BACKER ROD BOTH SIDES <br />FINISH FLOOR AS SCHEDULED <br />Gil <br />n TYPE Al & A4 - NR_3-5/8"MTL_FULL HEIGHT <br />vz =,'-o" <br />UNDERSIDE OF STRUCTURE ABOVE <br />2-1/r MTL TRACK <br />CEILING PER RCP <br />ACOUSTICAL BATT INSULATION PER WALL TYPE <br />5l8" TYPE "X" GWB (1) LAYER. EXTEND TO <br />STRUCTURE ABOVE. <br />2-11T MTL STUD <br />FINISH FLOOR AS SCHEDULED <br />'-311 <br />n TYPE G2 & G4 - NR FURR_2-1/2"MTL_6" ABV CLG <br />"1O 1vr=r-o• <br />UL# <br />tgb architects <br />t 425.778.1530 21911 76th Ave W. Ste 210 <br />f 425.774.7803 Edmonds WA 98026 <br />info@tgbarchilects.00m <br />www.tgbarchitects.com <br />PROVIDENCE <br />PMG MILL CREEK <br />CENTRALIZED <br />CHECK -IN <br />12800 BOTHELL-EVERETT HWY <br />EVERETT, WA 98208 <br />PERMIT SET <br />PARTITION TYPES <br />& DOOR & CEILING <br />INFORMATION <br />PROJECT INFORMATION <br />PROJECT NUMBER: <br />PROJECT LEAD: <br />DRAWN BY: <br />SHEET NO <br />A5.60 <br />1 2 1 3 1 4 1 5 6 <br />it <br />0 <br />0 <br />m <br />